Repeatability and reproducibility of Distraction Index (DI) measurements in the PennHIP method were evaluated in 100 dogs. The PennHIP distraction views sent to the PennHIP Analysis Center (PAC) were duplicated, digitalised, and identified with a code, and an adequate computer software was used for DI measurements. One examiner performed two DI measurement sessions, evaluating individually 200 hip joints. The scoring repeatability and reproducibility were estimated calculating the Intraclass Correlation Coefficient (ICC) between the two DI measurement sessions and between the second DI measurement session and the DI in PAC reports, respectively. The ICC for repeatability was 0.97 [95% confidence interval (CI), 0.96 to 0.98], and the ICC for reproducibility was 0.95 (95% CI, 0.93 to 0.96). The results suggest that the DI measurement method described is repeatable and can reproduce the PAC reports with confidence. Distraction indices measured in different PennHIP studies, using this DI measurement method and performed by trained researchers, can be considered interchangeable.
Farese, J. P., Todhunter, R. J., Lust, G., Williams, A. J. and Dykes, N. L. (1998): Dorsolateral subluxation of hip joints in dogs measured in a weight-bearing position with radiography and computed tomography. Vet. Surg. 27, 393-405.
'Dorsolateral subluxation of hip joints in dogs measured in a weight-bearing position with radiography and computed tomography ' () 27 Vet. Surg : 393 -405.
Flückiger, M. A., Friedrich, G. A. and Binder, H. (1999): A radiographic stress technique for evaluation of coxofemoral joint laxity in dogs. Vet. Surg. 28, 1-9.
'A radiographic stress technique for evaluation of coxofemoral joint laxity in dogs ' () 28 Vet. Surg : 1 -9.
Lee, J., Koh, D. and Ong, C. N. (1989): Statistical evaluations of agreement between two methods for measuring a quantitative variable. Comput. Biol. Med. 19, 61-70.
'Statistical evaluations of agreement between two methods for measuring a quantitative variable ' () 19 Comput. Biol. Med : 61 -70.
Ohlerth, S., Busato, A., Rauch, M., Weber, U. and Lang, J. (2003): Comparison of three distraction methods and conventional radiography for early diagnosis of canine hip dysplasia. J. Small Anim. Pract. 44, 524-529.
'Comparison of three distraction methods and conventional radiography for early diagnosis of canine hip dysplasia ' () 44 J. Small Anim. Pract : 524 -529.
Petrie, A. and Watson, P. (1999): Statistics for Veterinary and Animal Science. Blackwell Science, Oxford, 243 pp.
Statistics for Veterinary and Animal Science , () 243.
Smith, G. K., Biery, D. N. and Gregor, T. P. (1990): New concepts of coxofemoral joint stability and the development of a clinical stress-radiographic method for quantitating hip joint laxity in the dog. J. Am. Vet. Med. Assoc. 196, 59-70.
'New concepts of coxofemoral joint stability and the development of a clinical stress-radiographic method for quantitating hip joint laxity in the dog ' () 196 J. Am. Vet. Med. Assoc : 59 -70.
Smith, G. K., Gregor, T. P., Rhodes, H. and Biery, D. L. (1993): Coxofemoral joint laxity from distraction radiography and its contemporaneous and prospective correlation with laxity, subjective score, and evidence of degenerative joint disease from conventional hip-extended radiography in dogs. Am. J. Vet. Res. 54, 1021-1042.
'Coxofemoral joint laxity from distraction radiography and its contemporaneous and prospective correlation with laxity, subjective score, and evidence of degenerative joint disease from conventional hip-extended radiography in dogs ' () 54 Am. J. Vet. Res : 1021 -1042.
Smith, G. K., LaFond, E., Gregor, T. P., Lawler, D. F. and Nie, R. C. (1997): Within- and between-examiner repeatability of distraction indices of the hip joints in dogs. Am. J. Vet. Res. 58, 1076-1077.
'Within- and between-examiner repeatability of distraction indices of the hip joints in dogs ' () 58 Am. J. Vet. Res : 1076 -1077.