In order to decrease the organic load on the downstream domestic wastewater treatment plant, a three stage, fully aerated activated sludge system was established for the pretreatment of a vegetable processing wastewater. The results of the research verified that this design was inappropriate at the given, highly fluctuating wastewater quality. Nitrate formed through nitrification of the pea processing wastewater could not be denitrified, thus rising sludge occurred in the secondary clarifiers. On the other hand, during the corn campaign, severe deterioration of the COD (Chemical Oxygen Demand) removal efficiency, as well as the overproduction of extracellular polysaccharides leading to viscous bulking, were caused by the extremely high C/N ratio. In order to efficiently treat the wastewater of the vegetable processing industry, establishment of highly flexible systems with unaerated first stage proves to be necessary.

  • Austermann-Haun, U., Meyer, H., Seyfried, C.F. & Rosenwinkel, K.-H. (1997): Two examples of anaerobic pre-treatment of wastewater in the beverage industry. Wat. Sci. Technol. , 36 , 311–319.

    Rosenwinkel K.-H. , 'Two examples of anaerobic pre-treatment of wastewater in the beverage industry ' (1997 ) 36 Wat. Sci. Technol. : 311 -319.

    • Search Google Scholar
  • Austermann-Haun, U., Meyer, H., Seyfried, C.F. & Rosenwinkel, K.-H. (1999): Full scale experiences with anaerobic/aerobic treatment plants in the food and beverage industry. Wat. Sci. Technol. , 40 , 305–312.

    Rosenwinkel K.-H. , 'Full scale experiences with anaerobic/aerobic treatment plants in the food and beverage industry ' (1999 ) 40 Wat. Sci. Technol. : 305 -312.

    • Search Google Scholar
  • Jenkins, D., Richard, M.G. & Daigger, G.T. (1993): Manual on the causes and control of activated sludge bulking and foaming . 2nd ed., Lewis, Ann Arbor.

    Daigger G.T. , '', in Manual on the causes and control of activated sludge bulking and foaming , (1993 ) -.

  • Jobbágy, A., Literáthy, B. & Tardy, G. (2002): Implementation of glycogen accumulating bacteria in treating nutrient-deficient wastewater. Wat. Sci. Technol. , 46 , 185–190.

    Tardy G. , 'Implementation of glycogen accumulating bacteria in treating nutrient-deficient wastewater ' (2002 ) 46 Wat. Sci. Technol. : 185 -190.

    • Search Google Scholar
  • Masse, L. & Massé, D.I. (2005): Effect of soluble organic, particulate organic, and hydraulic shock loads on anaerobic sequencing batch reactors treating slaughterhouse wastewater at 20 °C. Process Biochem. , 40 , 1225–1232.

    Massé D.I. , 'Effect of soluble organic, particulate organic, and hydraulic shock loads on anaerobic sequencing batch reactors treating slaughterhouse wastewater at 20 °C ' (2005 ) 40 Process Biochem. : 1225 -1232.

    • Search Google Scholar
  • Yamamoto, R. & Matsui, S. (1989): Influence of contact loading on polysaccharide storage and settleability of activated sludge. Wat. Sci. Technol. , 21 , 1639–1642.

    Matsui S. , 'Influence of contact loading on polysaccharide storage and settleability of activated sludge ' (1989 ) 21 Wat. Sci. Technol. : 1639 -1642.

    • Search Google Scholar
All Time Past Year Past 30 Days
Abstract Views 46 46 2
Full Text Views 20 8 0
PDF Downloads 8 2 0