A method has been described for the determination of trace amounts of copper in biological samples by thermal neutron activation analysis, involving radiochemical separation of copper from irradiated matrix employing substoichiometric extraction of Cu/II/ with 2-mercaptobenzothiazole /2-HMBT/ into chloroform. 4.01 g of Cu/II/ can be determined with an accuracy of 3.13% and precision of 1.08%.