View More View Less
  • 1 Battelle, Pacific Northwest Laboratories Richland 99352 Washington (USA)
  • | 2 Electric Power Research Institute 94303 Palo Alto California (USA)
Restricted access

Abstract  

Battelle, Pacific Northwest Laboratories has recently developed, tested and field-demonstrated a technology for the direct assay of transuranic radionuclides (TRU), fission products, and activation products in a variety of radwaste packages generated at commercial nuclear power plants. This technology involves non-destructive passive neutron counting for determination of nanocurie/gram quantities of the TRU radionuclides. Direct gamma spectrometry combined with thermoluminescent dosimetry (TLD) and correlation analysis is also utilized to determine the concentrations of the fission and activation products present in the radwaste packages. Employing counting times of 10 to 20 minutes, a complete analysis of all radionuclides specified for assay by the U.S. Nuclear Regulatory Commission (in 10CFR61) prior to shallow-land disposal of commercial radwastes can be measured at concentrations at least tenfold below the least restrictive Class A waste catagory.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)