Authors:
W. Maenhaut Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Ghent (Belgium)

Search for other papers by W. Maenhaut in
Current site
Google Scholar
PubMed
Close
,
G. Ducastel Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Ghent (Belgium)

Search for other papers by G. Ducastel in
Current site
Google Scholar
PubMed
Close
,
R. Hillamo Finnish Meteorological Institute Sahaajankatu 22 E SF-00810 Helsinki (Finland)

Search for other papers by R. Hillamo in
Current site
Google Scholar
PubMed
Close
,
T. Pakkanen Finnish Meteorological Institute Sahaajankatu 22 E SF-00810 Helsinki (Finland)

Search for other papers by T. Pakkanen in
Current site
Google Scholar
PubMed
Close
, and
J. Pacyna Norwegian Institute for Air Research P.O. Box 64 N-2001 Lillestrøm (Norway)

Search for other papers by J. Pacyna in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

Atmospheric aerosol samples were collected during spring sampling campaigns in 1988 and 1989 at Birkenes and Nordmoen in southern Norway. The aerosol collectors used included stacked filter units (SFUs), a low volume sampler (referred to as ILVS), which consists of a filter preceded by three impaction stages, and an 11-stage Berner low-pressure impactor (LPI). All samples were analyzed for up to about 40 elements by INAA and PIXE. The resuls obtained from parallel samplings were intercompared in terms of ratios ILVS/SFU and LPI/SFU, whereby these ratios were calculated separately for the coarse and fine size fractions. For the ILVS/SFU parallel samplings, excellent agreement was observed between the results for the fine fraction, with the overall mean average ratio (based on 21 samples and 22 elements) being 0.99±0.10. For the coarse fraction, the overall mean ILVS/SFU ratio (based on 21 elements) was 0.75±0.13. This low result is explained by different upper-particle-size cut-offs of the two samplers. For the parallel samplings with LPI and SFU, the agreement was poorer, but still reasonable. The atmospheric concentrations observed at the two sites in the two campaigns and also the LPI size distributions for the various elements are discussed briefly.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)