View More View Less
  • 1 DSM Research B.V. Radioisotope Applications & Support P.O. Box 18 6160 MD Geleen The Netherlands
  • | 2 University of Ghent Laboratory of Analytical Chemistry, Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Ghent Belgium
  • | 3 KFKI-Atomic Energy Research Institute of the Hungarian Academy of Sciences P.O. Box 49 H-1525 Budapest Hungary
Restricted access

Abstract  

To account for varying dead time (frequently occurring when the measuring time is comparable with the half lives of the radionuclides in question) the use of Westphal's Loss-Free Counting technique (LFC) is preferable. However, standard gamma-ray spectrum deconvolution programs can not be applied in connection with LFC spectrometers, since this technique strongly influences the counting statistics of measured spectra. As consequence, erroneous results are likely to arise when applying peak search routines or when calculating the standard deviation of fitted peak areas or detection limits. To overcome these shortcomings, an LFC module equipped with Dual LFC Mode option should be used: this accumulates an LFC-corrected spectrum simultaneously with an uncorrected spectrum. The KAYZERO evaluation software has been modified to handle such tandem spectra.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)