Authors:
J. Coates Clemson University Department of Environmental Engineering and Science Clemson SC 29634-0919 USA

Search for other papers by J. Coates in
Current site
Google Scholar
PubMed
Close
,
R. Fjeld Clemson University Department of Environmental Engineering and Science Clemson SC 29634-0919 USA

Search for other papers by R. Fjeld in
Current site
Google Scholar
PubMed
Close
,
A. Paulenova Comenius University Department of Natural Sciences Bratislava Slovakia

Search for other papers by A. Paulenova in
Current site
Google Scholar
PubMed
Close
, and
T. DeVol Clemson University Department of Environmental Engineering and Science Clemson SC 29634-0919 USA

Search for other papers by T. DeVol in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

A system using an ion chromatograph coupled to a flow-cell scintillation detector for rapidly measuring the oxidation states of actinides at low concentrations (<10–6M) in aqueous solutions was evaluated. The key components of the system are a cation–anion separation column (Dionex, CS5) and a flow cell detector with scintillating cerium activated glass beads. The typical procedure was to introduce a 0.5 ml aliquot of sample spiked with actinides in the +III to +VI oxidation states into a 5 ml sample loop followed by 4 ml of synthetic groundwater simulant. Separation was achieved at a flow rate of 1 ml/min using an isocratic elution with oxalic, diglycolic, and nitric acids followed by distilled water. Tests were first conducted to determine elution times and recoveries for an acidic solution (pH 2) and a ground water simulant (pH 8) containing Am(III), Pu(IV), Th(IV), Pu(V), and U(VI). Then, an analysis was performed using a mixture of Pu(IV), Pu(V), and Pu(VI) in the ground water simulant and compared to results using the DBM extraction technique. Approximate elution times were the same for both the acidic solution and the ground water simulant. These were as follows: Pu(V) at 10 min, Am(III) at 15 min, Pu(IV) at 25 min, Th (IV) at 28 min and U(VI) at 36 min. Recoveries for the acidic solution were quantitative for U(VI) and Th(IV) and exceeded 80% for Am(III). Recoveries for the ground water simulant were quantitative for U(VI), but they were generally not quantitative for Th(IV), Pu(IV), and Am(III). For Th(IV) and Pu(IV), less than quantitative recoveries were attributed to the formation of neutral hydroxides and colloids; for Am(III) they were attributed to insoluble carbonates and/or hydroxycarbonates. When applied to the measurement of plutonium in the ground water simulant, the technique provided showed good agreement with the dibenzoylmethane (DBM) extraction technique, but it could not distinguish between Pu(V) and Pu(VI). This was likely due to the reduction of Pu(VI) to Pu(V) in the sample by the oxalic acid eluent. However, in spite of this limitation, the technique can be used to distinguish between Pu(IV) and Pu(V) in aqueous environmental samples within a pH range of 4 to 8 and an EH range of -0.2 to 0.6 V, the predominance region for Pu(III), (IV), and (V). In addition, this technique can be used to corroborate oxidation state analysis from the dibenzoylmethane (DBM) extraction method for environmental samples.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)