View More View Less
  • 1 ITN - Instituto Tecnológico e Nuclear Apartado 21, E.N. 10 2686-953 Sacavém Portugal
Restricted access

Abstract  

At ITN, PM10 and PM2.5 aerosols were collected on Nuclepore® polycarbonate filters of 47 mm diameter, using Gent samplers at 15–17 l/min air flux. Filters were analyzed by INAA and PIXE. The availability of certified filters was very scarce, viz.: (1) fly ash embedded in a methyl cellulose 47 mm foil 10 µm thick, BCR CRM128, (2) particle-size reduced air particulate matter (APM) to simulate PM2.5 aerosol matter deposited on a 47 mm polycarbonate filter membrane, NIST SRM 2783. The high price and scarcity of APM standards did not permit their frequent use for analytical quality control. At ITN, to control the filter results' accuracy, the chemical elements potassium, iron and zinc, determined by both techniques, were systematically compared. After a few improvements introduced in INAA, this technique was now considered at ITN as the reference technique in air particulate measurements. Comparison of INAA to PIXE was discussed. Compared to previously reported situation it was concluded that the results were in better agreement for iron and zinc, and potassium values were still biased to the same extent as before.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)