Authors:
Songsheng Jiang Department of Radiochemistry, China Institute of Atomic Energy P.O. Box 275-8, Beijing 102413, P.R. China

Search for other papers by Songsheng Jiang in
Current site
Google Scholar
PubMed
Close
,
Zhiyuan Chang Department of Radiochemistry, China Institute of Atomic Energy P.O. Box 275-8, Beijing 102413, P.R. China

Search for other papers by Zhiyuan Chang in
Current site
Google Scholar
PubMed
Close
,
Min Zhao Department of Radiochemistry, China Institute of Atomic Energy P.O. Box 275-8, Beijing 102413, P.R. China

Search for other papers by Min Zhao in
Current site
Google Scholar
PubMed
Close
,
Yonggang Zhao Department of Radiochemistry, China Institute of Atomic Energy P.O. Box 275-8, Beijing 102413, P.R. China

Search for other papers by Yonggang Zhao in
Current site
Google Scholar
PubMed
Close
,
X. L. Zhao IsoTrace Laboratory, University of Toronto 60 St. George St., Toronto, Ontario, M5S 1A7, Canada

Search for other papers by X. L. Zhao in
Current site
Google Scholar
PubMed
Close
, and
W. E. Kieser IsoTrace Laboratory, University of Toronto 60 St. George St., Toronto, Ontario, M5S 1A7, Canada

Search for other papers by W. E. Kieser in
Current site
Google Scholar
PubMed
Close
Restricted access

Summary  

Under an IAEA project for upgrading of reference materials, a new determination of the 129I concentration in the IAEA-375 reference material was performed. A chemical procedure was set up for the preparation of the AgI samples. Measurement of 129I was carried out using the IsoTrace Tandetron AMS facility at University of Toronto. To ensure the accuracy of the calibration, the tuning of the AMS system was iterated using not only the QC (quality control) samples but also all unknown samples. To minimize any possible current-dependent effects between 129I and 127I ions in the injection magnet, low Cs+ sputtering beam intensity (10 μA) was used. The reproducibility in determining the 129I/127I ratio in the IAEA-375 AgI samples was less than 1%. The activity concentration (CA) of 129I in the IAEA-375 reference material was determined to be 1.59±0.08 mBq . kg-1 at 95% confidence level. The present value is about 7% lower than the IAEA recommended value (1.7 mBq . kg-1) listed in 2000 or 20% lower than the recommended value (2 mBq . kg-1) listed in the IAEA AQCS Reference Material Catalogue (2002-2003). Since the IAEA recommended values for IAEA-375 materials was issued about 10 years ago and error range of the recommended values were large, the results we obtained might be useful in upgrading the recommended value.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)