Summary  

The removal of cesium from aqueous waste solution was investigated in a column setup using a relatively coarse SuperLigÒ644 resin. The bed volume (BV=140) at the onset of breakthrough surpassed the design requirement of 100 BV at 50% breakthrough, and also corresponds to 99.96% cesium removal. Cesium elution with 0.5M HNO3was satisfactory with a peak BV of 2.5. The elution BV for C/C0=0.01 was 10, which is less than the target of 15 BV. The percent of sorbed cesium eluted was 99.88%. Further, the BV of the various solutions used for the supporting process steps was sufficient.