Recycled steel products demands a new technique for determining tramp elements in steel. In this paper, As and Sb in iron certified reference materials were determined by neutron activation analysis with the multiple gamma-ray detection method. The determined values are in good agreement with certified and reference values. The lower determination limits (LDL) for As and Sb in high purity iron are 0.012 and 0.0025 ppm, respectively. As the demanded LDL for As and Sb is 0.1 ppm, the method described in this work is suitable for determining As and Sb in recycled steel.