View More View Less
  • 1 Pontifícia Universidade Católica de Minas Gerais, Programas de Pósgraduação — Mestrado em Odontologia Av. Dom José Gaspar, 500, Prédio 46 CEP 30535-610 Belo Horizonte-MG Brazil
  • | 2 Nuclear Technology Development Centre/CDTN-Brazilian Commission for Nuclear Energy/CNEN Belo Horizonte-MG Brazil
  • | 3 Pontifícia Universidade Católica de Minas Gerais, Programas de Pós Graduação Belo Horizonte-MG Brazil
  • | 4 Nuclear Technology Development Centre/CDTN-Brazilian Commission for NuclearEnergy/CNEN, Laboratory for Neutron Activation Analysis Belo Horizonte-MG Brazil
Restricted access

Abstract  

The present study determines the elementary alloy composition of ten commercial brands of brackets, especially related to Ni, Cr, and Co metals, confirmed allergenic elements. The nuclear techniques applied in the analyses were X-ray fluorescence (XRF) — Centre National de la Recherche Scientifique, France (National Center of Scientific Research), and X-ray energy spectrometry (XRES), and Instrumental Neutron Activation Analysis (INAA) — CDTN/CNEN, Brazil. The XRES and XRF techniques identified Cr in the 10 samples analyzed and Ni in eight samples. The INAA technique identified the presence of Cr (14% to 19%) and Co (42% to 2400 ppm) in all samples. The semi-quantitative analysis performed by XRF also identified Co in two samples. The techniques were effective in the identification of metals in orthodontic brackets. The elements identified in this study can be considered one of the main reason for the allergic processes among the patients studied. This finding suggests that the patients should be tested for allergy and allergenic sensibility to metals prior to the prescription of orthodontic device.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)