Authors:
S. Park Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Yuseong, 105, Daejeon, 305-600 Republic of Korea

Search for other papers by S. Park in
Current site
Google Scholar
PubMed
Close
,
Y. Park Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Yuseong, 105, Daejeon, 305-600 Republic of Korea

Search for other papers by Y. Park in
Current site
Google Scholar
PubMed
Close
,
Y. Ha Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Yuseong, 105, Daejeon, 305-600 Republic of Korea

Search for other papers by Y. Ha in
Current site
Google Scholar
PubMed
Close
, and
K. Song Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Yuseong, 105, Daejeon, 305-600 Republic of Korea

Search for other papers by K. Song in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

In this work, an easy, fast and reliable measurement technique for the quantitative determination of retained fission gases in an irradiated oxide fuel was developed. Many experiments were conducted to determine the optimum conditions for fusion of an oxide fuel, for the quantitative collection and measurements of the released gases. Ion implantation technology was applied to make a krypton or xenon references in a solid matrix. A fragment of oxide fuel, about 0.1 g of an unirradiated SIMFUEL, was completely fused with excess metallic fluxes, 1.0 g of nickel and 1.0 g of tin, in a graphite crucible of a helium atmosphere for 120 s at 850 A as a mixture of metals and alloys. About 96 ± 3 to 98 ± 4% of the krypton and xenon that were injected into the instrument using a standard gas mixture was reproducibly recovered by collecting the releasing gas through the instrument for 120 s. Using the same fusion and collection conditions, it was possible to recover about 97 ± 3% of the injected krypton and xenon by fusing a fragment of SIMFUEL which was wrapped with krypton or xenon implanted aluminum foils. The recovery test results of krypton and xenon using ion planted aluminum foils gave encouraging results suggesting their potential use as a reference specimen. It was confirmed that a fragment of irradiated oxide fuel, 0.051 g, with a code burn-up of 56.9 MWd/MtU, was completely fused as the mixture of metals and alloys through the fusion conditions and more than 99% of the retained fission gases were recovered during the first fusion. Since no cryogenic trap was needed, the collected gas could be measured directly and thus the analysis time could be further reduced. Approximately 7 min was sufficient to finish the measurement of retained fission gases in the irradiated oxide fuel using the developed procedure.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)