The Nitinol stent was bombarded in a cyclotron at a flux rate of 4 μA/cm2 to produce 48V via 48Ti (p, n) 48V reaction. In this study dose distribution of 48V radioactive stent was investigated for renal arteries. Version X-2.6 of the MCNP Monte Carlo radiation transport system code was employed to calculate dose distribution around the stent. As 48V is a mixed gamma and beta particle emitter, two separate runs of MCNP for both beta and gamma particles were performed and the total deposited dose was acquired by adding the two mentioned values. In order to verify the simulation, the calculated results have been compared with previous published data for the source. Calculated results show high dose gradient near the stent and the maximum amount of dose deposits at the vessel wall. According to (AAPM) TG-60/149 protocol, the dosimetric parameters, including geometry function, G(ρ,z), radial dose function, gL(ρ), and anisotropy function, F(ρ,z), were also determined.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)