Authors:
A. Simonits Central Research Institute for Physics P.O. Box 49 H-1525 Budapest 114 Hungary

Search for other papers by A. Simonits in
Current site
Google Scholar
PubMed
Close
,
S. Jovanović State University Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Gent Belgium

Search for other papers by S. Jovanović in
Current site
Google Scholar
PubMed
Close
,
F. De Corte State University Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Gent Belgium

Search for other papers by F. De Corte in
Current site
Google Scholar
PubMed
Close
,
L. Moens State University Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Gent Belgium

Search for other papers by L. Moens in
Current site
Google Scholar
PubMed
Close
, and
J. Hoste State University Institute for Nuclear Sciences Proeftuinstraat 86 B-9000 Gent Belgium

Search for other papers by J. Hoste in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

When making use of some single comparator or absolute standardization methods in reactor neutron and in epicadmium neutron activation analysis, the knowledge of the effective resonance energy (
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
) is essential to correct for the effect of the nonideal epithermal flux distribution on the analysis result.
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
can be calculated from neutron resonance data, but when these are incomplete, not accurate or even not known at all, experimental determination should be considered. Such a method, providing both
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
and the resonance integral to 2200 ms–1 cross-section ratio (QO), is described in this paper. Results are given for 11 isotopes.
  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)