Authors:
A. Carpenter New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by A. Carpenter in
Current site
Google Scholar
PubMed
Close
,
T. Mysliwy New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by T. Mysliwy in
Current site
Google Scholar
PubMed
Close
,
S. Sivakoff New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by S. Sivakoff in
Current site
Google Scholar
PubMed
Close
,
M. Doshi New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by M. Doshi in
Current site
Google Scholar
PubMed
Close
,
E. Wolshin New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by E. Wolshin in
Current site
Google Scholar
PubMed
Close
,
M. Matthew New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by M. Matthew in
Current site
Google Scholar
PubMed
Close
,
G. Schnaper New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by G. Schnaper in
Current site
Google Scholar
PubMed
Close
,
V. Subramanyam New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by V. Subramanyam in
Current site
Google Scholar
PubMed
Close
, and
L. Camin New England Nuclear, Radiopharmaceuticals Research Department 331 Treble Cove Road 01862 N. Billerica Mass. (USA)

Search for other papers by L. Camin in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

A simple, low cost TLC scanner system for the characterization of -emitting radiopharmaceuticals is described. The TLC scanner has a linear response range of 0.074 Mbq up to 2.94 Mbq. The accuracy and reproducibility of measurement is better than ±5% (relative). The utility of this TLC scanner system is demonstrated by application to the radioanalytical evaluation of99mTc(dmpe)2Cl 2+ preparations. A comparison with HPLC radioanalytical separations is made.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
1
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)