A simultaneous thermal analysis/mass spectroscopy system was used for the determination of halogenated hydrocarbons in polymeric foam insulation materials. The investigation of ten different polymeric foams show that this equipment is a sensitive and reliable tool for the identification and determination of the bubbling agent. The results are compared with the Purge and Trap method.