View More View Less
  • 1 Nuclear Research Institute, Řež plc Department of Radiation Applications 250 68 Řež Czech Republic 250 68 Řež Czech Republic
Restricted access

Abstract  

The results of determination of activation energies (EA) of polymeric cable insulations obtained by conventional methods (usually based on the evaluation of changes of mechanical properties of insulations after their ageing in thermal chamber at different temperatures) have been compared with results obtained by methods employing the differential scanning calorimetry (DSC). Three DSC methods have been tested: the method according the ASTM E 698; measuring of DSC characteristics in the isothermal mode at several different temperatures; and the method based on evaluation of DSC characteristics of insulations after their thermal ageing in thermal chamber. The last method — which can be called as a modified conventional method, because instead of mechanical properties, the DSC characteristics are determined — has been found as most acceptable and giving similar values of EA as the other conventional methods.