Authors:
W. P. C. de Klerk TNO Prins Maurits Laboratory P.O. Box 45, Rijswijk, The Netherlands

Search for other papers by W. P. C. de Klerk in
Current site
Google Scholar
PubMed
Close
,
E. L. M. Krabbendam-LaHaye TNO Prins Maurits Laboratory P.O. Box 45, Rijswijk, The Netherlands

Search for other papers by E. L. M. Krabbendam-LaHaye in
Current site
Google Scholar
PubMed
Close
,
B. Berger Armasuisse, Science and Technology Centre 3602 Thun, Switzerland

Search for other papers by B. Berger in
Current site
Google Scholar
PubMed
Close
,
H. Brechbuhl Armasuisse, Science and Technology Centre 3602 Thun, Switzerland

Search for other papers by H. Brechbuhl in
Current site
Google Scholar
PubMed
Close
, and
C. Popescu RWITH Veltmannplatz, Aachen, Germany

Search for other papers by C. Popescu in
Current site
Google Scholar
PubMed
Close
Restricted access

Summary Thermal analysis is an interesting technique to determine kinetic parameters of separate components, and also of a complete system to receive adequate information on the ageing process of pyrotechnic compositions. The investigated tracer is a tracking tracer of a Swiss missile. It is attached to a missile and produces during burning a red flame. The missile system is already in use for 15 years. Periodic inspections of the system take place every three years. These inspections, however only give information on the actual state of the tracer and not on the future state. The aim of this investigation is to predict the ageing behaviour of the tracer system to give additional information about the future use of the missile system. After two ageing profiles the tracer systems were tested on the test range at Armasuisse in Thun. The results of the testing show that an ageing period of 4 weeks at 60°C gives no changes in performance (light output and burning time). On the other side also a quite heavy ageing period of 4 weeks at 150°C was applied on tracer systems, which gives a dramatically change in burning time. The light output was even higher after this ageing profile, although the intensity changes a lot.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Thermal Analysis and Calorimetry
Language English
Size A4
Year of
Foundation
1969
Volumes
per Year
1
Issues
per Year
24
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 1388-6150 (Print)
ISSN 1588-2926 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Apr 2024 14 0 0
May 2024 0 0 0
Jun 2024 2 0 0
Jul 2024 1 0 0
Aug 2024 5 0 0
Sep 2024 7 0 0
Oct 2024 0 0 0