Authors:
Ana Gomes Federal University of Paraíba – UFPB Unified Development and Medicine Assays Laboratories – LUDEM João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba

Search for other papers by Ana Gomes in
Current site
Google Scholar
PubMed
Close
,
Lidiane Correia Federal University of Paraíba – UFPB Unified Development and Medicine Assays Laboratories – LUDEM João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba

Search for other papers by Lidiane Correia in
Current site
Google Scholar
PubMed
Close
,
Mônica da Silva Simões Federal University of Paraíba – UFPB Unified Development and Medicine Assays Laboratories – LUDEM João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba

Search for other papers by Mônica da Silva Simões in
Current site
Google Scholar
PubMed
Close
, and
R. Macêdo Federal University of Paraíba – UFPB Unified Development and Medicine Assays Laboratories – LUDEM João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba João Pessoa Brasil 58051-970 Cidade Universitária, Campus I – CCS Paraíba

Search for other papers by R. Macêdo in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

The objective of this work was to develop and validate a fast and reproducible method to determine the concentration of metronidazole in drug substance and tablets. The samples were analyzed by dynamic thermogravimetry, using 10, 20, 40, 60 and 80C min–1 heating rates in nitrogen and in nitrogen with synthetic air. Obtained data were used in the Antoine and Langmuir equations in order to have the pressure curves. Vapor pressure curves of drug and tablet of metronidazole were evaluated using the mathematical indexes of difference factor, f1, and similarity factor, f2, to compare their profiles. The data showed that there is no significant difference between the vapor pressure profiles of drug and tablet of metronidazole in both environmental conditions, which confirms that the process is really vaporization. The concentration of metronidazole was determined in the raw material and tablets of the drug.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Thermal Analysis and Calorimetry
Language English
Size A4
Year of
Foundation
1969
Volumes
per Year
1
Issues
per Year
24
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 1388-6150 (Print)
ISSN 1588-2926 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Jun 2024 10 0 0
Jul 2024 0 0 0
Aug 2024 13 0 0
Sep 2024 16 0 0
Oct 2024 35 0 0
Nov 2024 4 0 0
Dec 2024 0 0 0