A fully automated adiabatic calorimeter controlled on line by a computer used for heat capacity measurements in the temperature range from 80 to 400 K was constructed. The hardware of the calorimetric system consisted of a Data Acquisition/Switch Unit, 34970A Agilent, a 7 1/2 Digit Nano Volt /Micro Ohm Meter, 34420A Agilent, and a P4 computer. The software was developed according to modern controlling theory. The adiabatic calorimeter consisted mainly of a sample cell equipped with a miniature platinum resistance thermometer and an electric heater, two (inner and outer) adiabatic shields, two sets of six junction differential thermocouple piles and a high vacuum can. A Lake Shore 340 Temperature Controller and the two sets of differential thermocouples were used to control the adiabatic conditions between the cell and its surroundings. The reliability of the calorimeter was verified by measuring the heat capacities of synthetic sapphire (α-Al2O3), Standard Reference Material 720. The deviation of the data obtained by this calorimeter from those published by NIST was within ±0.1% in the temperature range from 80 to 400 K.

Manuscript Submission: HERE

  • Impact Factor (2019): 2.731
  • Scimago Journal Rank (2019): 0.415
  • SJR Hirsch-Index (2019): 87
  • SJR Quartile Score (2019): Q3 Condensed Matter Physics
  • SJR Quartile Score (2019): Q3 Physical and Theoretical Chemistry
  • Impact Factor (2018): 2.471
  • Scimago Journal Rank (2018): 0.634
  • SJR Hirsch-Index (2018): 78
  • SJR Quartile Score (2018): Q2 Condensed Matter Physics
  • SJR Quartile Score (2018): Q2 Physical and Theoretical Chemistry

For subscription options, please visit the website of Springer.

Journal of Thermal Analysis and Calorimetry
Language English
Size A4
Year of
Foundation
1969
Volumes
per Year
4
Issues
per Year
24
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 1388-6150 (Print)
ISSN 1588-2926 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Jun 2021 2 0 0
Jul 2021 2 0 0
Aug 2021 5 0 0
Sep 2021 2 0 0
Oct 2021 3 0 0
Nov 2021 11 0 0
Dec 2021 0 0 0