Authors:
,
Z. Tan Dalian Institute of Chemical Physics, Chinese Academy of Sciences Thermochemistry Laboratory Dalian 116023 China

Search for other papers by Z. Tan in
Current site
Google Scholar
PubMed
Close
,
Q. Shi

Search for other papers by Q. Shi in
Current site
Google Scholar
PubMed
Close
, and
B. Liu Hunan University of Arts and Science Department of Chemistry Changde 415000 China

Search for other papers by B. Liu in
Current site
Google Scholar
PubMed
Close
H. Zhang Dalian Institute of Chemical Physics, Chinese Academy of Sciences Thermochemistry Laboratory Dalian 116023 China

Search for other papers by H. Zhang in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract  

A fully automated adiabatic calorimeter controlled on line by a computer used for heat capacity measurements in the temperature range from 80 to 400 K was constructed. The hardware of the calorimetric system consisted of a Data Acquisition/Switch Unit, 34970A Agilent, a 7 1/2 Digit Nano Volt /Micro Ohm Meter, 34420A Agilent, and a P4 computer. The software was developed according to modern controlling theory. The adiabatic calorimeter consisted mainly of a sample cell equipped with a miniature platinum resistance thermometer and an electric heater, two (inner and outer) adiabatic shields, two sets of six junction differential thermocouple piles and a high vacuum can. A Lake Shore 340 Temperature Controller and the two sets of differential thermocouples were used to control the adiabatic conditions between the cell and its surroundings. The reliability of the calorimeter was verified by measuring the heat capacities of synthetic sapphire (α-Al2O3), Standard Reference Material 720. The deviation of the data obtained by this calorimeter from those published by NIST was within ±0.1% in the temperature range from 80 to 400 K.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Thermal Analysis and Calorimetry
Language English
Size A4
Year of
Foundation
1969
Volumes
per Year
1
Issues
per Year
24
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 1388-6150 (Print)
ISSN 1588-2926 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Apr 2023 7 2 3
May 2023 1 0 0
Jun 2023 3 0 0
Jul 2023 5 0 0
Aug 2023 12 0 0
Sep 2023 8 0 0
Oct 2023 0 0 0