An isocratic RP-HPLC-UV method for analysis of sumatriptan succinate in pharmaceutical dosage forms has been developed and validated. Best separation was achieved on a Thermo Hypersil C4 column (250 mm × 4.6 mm, 5 µm) using a mobile phase of 20 mM potassium dihydrogen phosphate adjusted to pH 4.0 with orthophosphoric acid and acetonitrile (65:35, v/v) at a flow rate of 1.0 mL min−1. UV detection was performed at 227 nm. The method was validated for specificity, linearity, precision, accuracy, limit of quantification, limit of detection, robustness, and solution stability. The calibration plot was linear over the concentration range 25–600 ng mL−1 (r2 = 0.9998) and the limits of detection and quantification were 10 and 25 ng mL−1, respectively. Intra-day and inter-day precision and accuracy were between 1.25 and 2.95% and between −1.15 and 2.47%, respectively. The method was successfully used for analysis of sumatriptan succinate, in the presence of excipients, in orally disintegrating tablets prepared in our laboratory and in commercially available tablets (Imigran) and nasal spray (Suminat).
[1]. B.D. Dulery M.A. Petty J. Schoun M. David N.D. Huebert 1997 J. Pharm. Biomed. Anal. 15 1009.
[2]. M.J. Nozal J.L. Bernal L. Toribio M.T. Martin F.J. Diez 2002 J. Pharm. Biomed. Anal. 30 285.
[3]. C. Balaguer-Fernandez A. Femenia-Font S.D. Rio-Sancho V. Merino A. Lopez-Castellano 2008 J. Pharm. Sci. 97 2102.
[4]. A. Femenia-Font V. Merino V. Rodilla A. Lopez-Castellano 2005 J. Pharm. Biomed. Anal. 37 621.
[5]. A. Femenia-Font C. Balaguer-Fernandez V. Merino V. Rodilla A. L.- Castellano 2005 Eur. J. Pharm. Biopharm. 61 50.
[6]. J. Klancke 2003 Dissolut Technol. 10 6.
[7]. V.A. Shrisat S.Y. Gabhe S.G. Deshpande 1998 Indian Drugs 35 404.
[8]. S. Sukhdev R. Jain 1997 Indian Drugs 34 527.
[9]. N. Badwe N. Sharma 1997 Eastern Pharmacist XL 121.
[10]. S.S. Shidhaye N.S. Saindane P.V. Thakkar S.B. Sutar V.J. Kadam 2007 Indian J. Pharm. Sci. 69 729.
[11]. A.B. Avadhanulu J.S. Srinivas Y. Anjaneyulu 1996 Indian Drugs 33 334.
[12]. D.N. Tipre P.R. Vavia 1999 Indian Drugs 36 501.
[13]. L.I. Bebawy A.A. Moustafa N.F. Abo-Talib 2003 J. Pharm. Biomed. Anal. 32 1123.
[14]. K. Sagar J.M.F. Alvarez C. Hua M.R. Smyth R. Munden 1992 J. Pharm. Biomed. Anal. 10 17.
[15]. K.D. Altria S.D. Filbey 1993 Anal. Proc. 30 363.
[16]. K.D. Altria S.D. Filbey 1993 J. Liq. Chromatogr. Relat. Technol. 16 2281.
[17]. International Conference on Harmonization (ICH), Validation of Analytical Procedures: Text and Methodology Q2 (R1), November 2005.
[18]. USFDA. 1994 Validation of Chromatographic Methods US Department of Health and Human Services, Food and Drug Administration, Centre for Drug Evaluation and Research (CDER) Rockville, MD.