The role of light-emitting diode lamps and radio frequency lighting controls is to reduce the energy consumption. The increase of lighting network complexity determines the increase of EMC noise emission. Being familiar with measurement systems is important for making correct measurement and for understanding the results of the measurement. Correct interpretation of measurement results is the first step in choosing the best suppression method. The suppression method depends on the common mode and the differential mode of noise type and on the frequency of signal noise.
Baranyai B. ; Póth B.; Kistelegdi I. Planning and research of smart buildings and constructions with the ‘Energydesign Roadmap’ method, Pollack Periodica, Vol. 8, No. 3, 2013, pp. 15–26.
Shaikh A. N. , Shah N., Tripathy A., Naikwadi M. H. Intelligent monitoring and control rendered to street lighting, International Conference on Advances in Technology and Engineering, Mumbai, India, 23-25 January 2013, pp. 1–5
Lee D. S. , Sung C. Z. RFID based intelligent lighting system development for the convenience store, IEEE International Conference on Systems Man and Cybernetics (SMC), Istanbul, Turkey, 10-13 October 2010, pp. 4012–4017.
Schaefer W. Signal detection with EMI receivers, IEEE International Symposium on Electromagnetic Compatibility, Denver, USA, 24-28 August, Vol. 2 1998, pp. 761–765.
Karaca T. , Deutschmann B., Winkler G. EMI-receiver simulation model with quasi-peak detector, IEEE International Symposium on Electromagnetic Compatibility, Dresden, Germany, 16-22 August 2015, pp. 891–896.
Ales A. , Schanen J. L., Moussaoui D., Roudet J. Impedances identification of DC/DC converters for network EMC analysis, IEEE Transactions on Power Electronics, Vol. 29, No. 12, 2014, pp. 6445–6457.
Miloudi M. , Bendaoud A., Miloudi H., Nemmich S., Slimani H. Analysis and reduction of common-mode and differential-mode EMI noise in a fly-back switch-mode power supply, 20th Telecommunications Forum, Belgrad, Serbia, 20-22 November 2012, pp. 1080–1083.
Gergely F. , Miklós K. Edge finite element method in case of high frequency simulations, Pollack Periodica, Vol. 10, No. 3, 2015, pp. 59–70.
EN 55015:2006, Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment, European Committee for Electrotechnical Standardization, 2006.
EN 300 220-1:2012, Electromagnetic compatibility and radio spectrum matters (ERM); Short range devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW, Part 1, Technical characteristics and test methods, European Committee for Electrotechnical Standardization, 2012.
Ghayem F. , Rassaei F. Helical antenna to measure radiated power density around a BTS, Design and implementation, 3rd Asia-Pacific Conference on Antennas and Propagation, Harbin, China, 26-29 July 2014, pp. 185–188.