The objective of this study is to simulate material selection for fabricating hip joint prostheses from light-weight, low-cost materials which are also strong and durable. In this study, Co-Cr alloy CoCrWNi (F90), stainless steel ASIS 410, and titanium alloys (Ti6Al4V) material selection as the potential candidate for the suggested implant to manufacture a joint that is characterized by lightweight, low cost, does not react chemically with the human body and can bear the weight of the patient without mechanical failure. With this study, it was concluded the stainless steel ASIS 410 was selected as the best material selection since it passed engineering analysis, acceptable weight, and low cost compared to other proposed materials.
Ikhsana , A. R. Prabowo , J. M. Sohn , and J. Triyono , “Finite element analysis of different artificial hip stem designs based on fenestration under static loading,” Proced. Struct. Integr., vol. 27, pp. 101–108, 2020.
M. Pawlikowski , K. Skalski , and M. Haraburda , “Process of hip joint prosthesis design including bone remodeling phenomenon,” Comput. Struct., vol. 81, pp. 887–893, 2003.
M. Ruyu , X. Wendong , W. Dongmei , D. Kerong , and W. Chengtao , “Design and manufacture of custom hip prostheses based on standard X-ray films,” Int. J. Adv. Manuf Technol., vol. 27, pp. 70–74, 2005.
A. T. Şensoy , M. Çolak , I. Kaymaz , and F. Findik , “Optimal material selection for total hip implant: A finite element case study,” Arab. J. Sci. Eng., vol. 44, no. 12, pp. 10293–10301, 2019.
H. F. El-Sheikh , B. J. MacDonald , and M. S. J. Hashmi , “Material selection in the design of the femoral component of cemented total hip replacement,” J. Mater. Process. Technol., vol. 122, nos 2–3, pp. 309–317, 2002.
D. Annur , M. S. Utomo , T. Asmaria , D. P. Malau , S. Supriadi , B. Suharno , A. J. Rahyussalim , Y. Prabowo , and M. I. Amal , “Material selection based on finite element method in customized iliac implant,” Mater. Sci. Forum, vol. 1000, pp. 82–89, 2020.
Y. E. Delikanli and M. C. Kayacan , “Design, manufacture, and fatigue analysis of lightweight hip implants,” J. Appl. Biomater. Funct. Mater., vol. 17, no. 2, pp. 1–8, 2019.
S. L. Gavali , S. H. Gawande , S. R. Patil , and R. N. Yerrawar , “Experimental stress analysis of hip joint implant for fracture analysis,” IOSR J. Mech. Civil Eng., vol. 1, pp. 20–31, 2016.
ASTM B557M-02a, Standard Test Methods of Tension Testing Wrought and Cast Aluminum and Magnesium Alloy Products. West Conshohocken, PA: ASTM International, 2002.
Rotating fatigue, High tec. HSM 20. [Online]. Available: https://www.scribd.com/document/126559537/Rotating-Fatigue-pdf. Accessed: Dec. 6, 2021.
L. Issler , “Fatigue failures,” in Failure analysis and prevention, vol. 11, B. A. Miller , R. J. Shipley , R. J. Parrington , and D. P. Dennies , Eds, ASM International Handbook, 2021.
C. Vulcu , A. Stratan , A. Ciutină , and D. Dubina , “Beam-to-column joints for seismic resistant dual-steel structures,” Pollack Period., vol. 6, no. 2, pp. 49–60, 2011.
C. Vulcu , A. Stratan , and D. Dubina , “Numerical simulation of the cyclic loading for welded beam-to-CFT column joints of dual-steel frames,” Pollack Period., vol. 7, no. 2, pp. 35–46, 2012.