Search Results

You are looking at 51 - 60 of 87 items for

  • Author or Editor: J. Hoste x
  • Refine by Access: All Content x
Clear All Modify Search

Abstract  

Vanadium in serum has been investigated by the aid of neutron activation analysis (8 min irradiation at 8·1013 n·cm−2·s−1 in the reactor FR-II of the Kernforschungszentrum in Karlsruhe). The lyophilized samples were dry-ashed before irradiation and the52V activity extracted after irradiation. The values for V in the sera of 22 healthy males ranged from 0.029–0.939 ng V·ml−1. There is a real assumption that some of the high figures are due to persons being contaminated with V. The 18 healthy females yielded a mean value of 0.033±0.012 ng V·ml−1 for 17 of them and one additional value of 0.139 ng V·ml−1. These V-data are the lowest ever reported in the literature. The analyses of two packed blood cell samples yielded 0.031 and 0.020 ng·g−1, indicating that about 68% of the total V in blood is present in serum. There was no correlation between the V-content and age, nor between the V-content and the cholesterol, triglycerides or the lipoprotein fractions in serum.

Restricted access

Abstract  

The infinite dilution resonance integrals of fifteen (n,γ)reactions leading to the production of short-lived radioisotopes were determined. The irradiation parameters were checked by comparing the results of different methods and the measuring equipment was carefully controlled.

Restricted access

Abstract  

The concept of the effective resonance energy
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
, formerly introduced as a parameter in the absolute (e.g. k0-) standardization methodology of (n, ) activation analysis, is elucidated with respect to dimensioning, accuracy and usefulness.
Restricted access

Abstract  

USGS BCR-1 and G-2, NBS 1633a Coal Fly-Ash and a 7-element synthetic standard for biological material have been analysed in this work by reactor NAA, using the k0-standardization method. The analyses were performed independently in the analytical laboratories of the Institute for Nuclear Sciences (INW), Gent, and the Central Research Institute for Physics (KFKI), Budapest. This procedure allowed not only a comparison with the specified data or with other published values, but enabled a check of the consistency of our own results obtained in largely different experimental circumstances. As concluded the k0-standardization method combines general versatility (with respect to irradiation and counting conditions) with good accuracy, while keeping the experimental work as simple as possible. Since the k0 method is a computer-oriented technique, a FORTRAN IV program was designed and applied on a VAX 11/780 machine.

Restricted access

Abstract  

Isotopic abundance values for50Cr,58Fe and109Ag and the absolute gamma-intensities for51Cr,59Fe and110mAg were evaluated. These evaluated data, together with experimental k0-determinations (i.e. from the
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\begin{gathered} {}^{5 0}Cr(n,\gamma )^{5 1} Cr; \sigma _0 = (15.2 \pm 0.2) barn [cf.:15.8 - 16.0] \hfill \\ {}^{5 8}Fe(n,\gamma )^{5 9} Fe; \sigma _0 = (1.31 \pm 0.03) barn [cf.:1.14 - 1.16] \hfill \\ {}^{1 0 9}Ag(n,\gamma )^{1 1 0 m} Ag;\sigma _0 = (3.89 \pm 0.05) barn [cf.:4.4 - 5.0] \hfill \\ \end{gathered}$$ \end{document}
Restricted access

Abstract  

The present paper deals with the experimental determination and the critical evaluation of Qo, the ratio of the resonance integral (Io) to the 2200 m.s–1 cross-section ( o) for 57 analytically interesting (n, ) reactions, including a revision and updating of formerly published results for 13 isotopes. Full account is given for deviations from the ideal epithermal neutron flux distribution. The Budapest-Gent cooperative determinations, yielding parallel but independent results, lead to recommended Qo-values with an average uncertainty as low as 3%. Finally, with the aid of independently evaluated or measured o-data, a list of recommended Io-values is given.

Restricted access

Abstract  

When making use of some single comparator or absolute standardization methods in reactor neutron and in epicadmium neutron activation analysis, the knowledge of the effective resonance energy (
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
) is essential to correct for the effect of the nonideal epithermal flux distribution on the analysis result.
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
can be calculated from neutron resonance data, but when these are incomplete, not accurate or even not known at all, experimental determination should be considered. Such a method, providing both
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar E_r$$ \end{document}
and the resonance integral to 2200 ms–1 cross-section ratio (QO), is described in this paper. Results are given for 11 isotopes.
Restricted access

Abstract  

By comparison of experimental k0-factors, determined in reactor positions with greatly different thermal-to-epithermal neutron flux ratios, and by comparison of experimentally determined and theoretically calculated k0-factors, it is possible in some cases to select best values from literature data for (n, γ) activation cross-sections and for absolute gamma intensities. This is demonstrated for97Zr,95Zr,56Mn and65Zn.

Restricted access

Abstract  

After critical evaluation of a number of existing standardization methods a new approach introducing generalized k0-factors was suggested in 1975 for use in (n, γ) reactor neutron activation analysis (RNAA). In order that the new method could soon be applied competitively in actual analytical work a cooperation between the Activation Analytical Laboratories of the Central Research Institute for Physics (KFKI), Budapest and the Institute for Nuclear Sciences (INW), Gent was established to determine the k0 and other related nuclear data (Q0, T1/2, Ēr, etc.) with a high accuracy, to develop procedures for monitoring essential irradiation and measuring parameters (Φse, α, ∈p,
\documentclass{aastex} \usepackage{amsbsy} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{bm} \usepackage{mathrsfs} \usepackage{pifont} \usepackage{stmaryrd} \usepackage{textcomp} \usepackage{upgreek} \usepackage{portland,xspace} \usepackage{amsmath,amsxtra} \pagestyle{empty} \DeclareMathSizes{10}{9}{7}{6} \begin{document} $$\bar \Omega$$ \end{document}
, etc.) as well as to share experiences when applying the method. This paper summarizes the main results of this cooperative work obtained in the last five years. The current status and recent developments in the k0-method are reviewed and a “Status and Request List” compiled from more than a thousand surveyed nuclear data on about 150 analitically important (n, γ) reactions in being prepared to suggest new or refined measurements and to prevent the use of unreliable data.
Restricted access

Abstract  

For 13 isotopes, the resonance integral to thermal crosssection ratio was studied. The results of two different methods, applied in two different laboratories, are compared. One method consists in a direct determination of I00-values from Cd-ratio measurements, the other is based on the evaluation of literature data, using accurately determined k0-factors from two irradiation channels with largely different thermal-to-epithermal flux ratios.

Restricted access