Search Results

You are looking at 1 - 4 of 4 items for :

  • Author or Editor: W.Q. Chen x
  • Chemistry and Chemical Engineering x
  • Refine by Access: All Content x
Clear All Modify Search

Abstract  

In our invention, FCC (fluid catalytic cracking) dry gas could be used to react with benzene without any special purification, and more than 90% ethylene was converted to ethylbenzene. The phenomenon of carbon deposition over catalyst surface was obvious and leads to a deactivation of catalyst, so it is important to study the behavior of carbon deposition of catalyst during alkylation of benzene. The influence of several factors such as temperature, reaction time, reactant concentration of the amount and the kinetics of carbon deposition were investigated, during which carbon depositing rate equations were obtained for different reactant.

Restricted access

Abstract  

Excess molar enthalpies of binary mixtures for tributyl phosphate (TBP)+methanol/ethanol were measured with a TAM air Isothermal calorimeter at 298.15 K and ambient. The results for xTBP+(1–x)CH3OH are negative in the whole range of composition, while the values for xTBP+(1–x)C2H5OH change from positive values at low x to small negative values at high x. The experimental results have been correlated with the Redlich–Kister polynomial. IR spectra of the mixtures were measured to investigate the effect of hydrogen bonding in the mixture.

Restricted access

Summary

A simple and rapid HPLC method using a photodiode array (PDA) detector for the analysis of 3-hydroxycarboplatin and its related complex has been established for the first time. Separation of 3-hydroxycarboplatin and 3-hydroxy-1,1-cyclobutanedicarboxylic acid (3-HO-cbdca) was carried out on a Phenomenex ODS3 column using an aqueous solution containing 50 mM ammonium acetate and 5 mM sodium 1-octanesulfonate as the mobile phase. The flow rate was 0.8 mL min−1, the column temperature was 40°C, and the detection wavelength was 230 nm for 3-hydroxycarboplatin and 220 nm for 3-HO-cbdca. Different analytical performance parameters such as precision, accuracy, linearity, stability of the solution, specificity, limit of detection (LOD), limit of quantification (LOQ), and system suitability were determined using the Empower 2 software. The calibration curve of standard 3-hydroxycarboplatin showed good linearity (r = 0.9995) within the range 0.5–1.4 mg mL−1. The method was accurate and precise, with an average accuracy of 100.4% (RSD = 1.53%, n = 9), and the results of the system suitability test showed symmetrical peaks, good resolution (R s), and repeatability. It can be applied to the quality control of 3-hydroxycarboplatin.

Open access

Abstract  

The iron contents in the hair and blood samples of 37 juvenile athletes who were supplemented with 0, 8 and 16 mg Fe/day, respectively, in the food of ferrous gluconatecontaining chocolate for 3 months were determined before and after the supplementation by INAA, SRXRF and blood analysis. The experimental results showed that after supplementation of the iron-fortified food, the normal ferritin level in the blood of the male athletes was attained and the iron content in the hair was increased with supplementation, but both are not in the positive proportion. Most of the female athletes had similar results. It is suggested that supplementation of 8 mg iron/day to juvenile athletes may be desirable.

Restricted access