], liquid chromatography–mass spectrometry (LC–MS) or liquid chromatography–tandem mass spectrometry LC–MS/MS [ 16 , 17 , 18 , 19 , 20 , 21 ], by ultra-performance liquid chromatography (UPLC) coupled to MS (UPLC–MS) [ 22 , 23 ], and high

Open access
Acta Chromatographica
Authors:
Bingying Hu
,
Yingying Sun
,
Min Wang
,
Zhisheng He
,
Shanshan Chen
,
Dake Qi
,
Zhen Ge
,
Lingling Fan
,
Jingfang Chen
, and
Yang Wei

%. UPLC-MS/MS instruments and parameters An API 5500 Triple Quad UPLC-MS/MS System (AB SCIEX, USA) was employed for UPLC-MS/MS analysis. Waters ACQUICY BEH C18 (2.1 × 100 mm, 1.7 μm) was selected as analytical column in this

Open access

The experiment was manipulated on an UPLC Acquity C 18 column (2.1 mm × 100 mm, 1.7 µm) maintaining at 40 °C. The mobile phases were consisted of solvent A (5 mmol/L ammonium acetate and 0.1% formic acid solution) and solvent B (acetonitrile) with a

Open access

pressure, which provides the ultra-performance liquid chromatography (UPLC) separation on a conventional HPLC system [ 17 , 18 , 26 ]. Hence, combining the advantages of HPLC-MS and poroshell column would be a good strategy to develop a rapid analytical

Open access

calculated in term of (mass of product)/(initial mass of vegetable matrix). The extraction products analysis UPLC PDA analyses were performed on Ultra Pressure Liquid Chromatographic Acquity system (UPLC, Acquity I-Class, Milan, Italy) consisting of a Waters

Open access

(BPR). The Waters ACQUITY UPLC H-Class system is equipped with a quaternary solvent manager, an autosampler, a column manager, and a PDA detector. Data acquisition and control of the SFC and ultrahigh-performance liquid chromatography (UHPLC) system

Open access

hospital ethical approval. Analytical instrumentation The analysis was performed using a ACQUITY UPLC H-Class System coupled with a XEVO TQD triple quadruple mass spectrometer (Waters Corp., Milford, MA, USA). The mass spectrometer was equipped with an

Open access

substances, either in products for the treatment of erectile dysfunction or in dietary supplements for weight loss by an ultra-performance liquid chromatography (UPLC) technique [ 14 , 15 ], liquid chromatography–mass spectrometry [ 16 ], and high

Open access

(Kala SG, et al., 2021) [ 9 ] HPLC No 10–2,000 35 100 2022 (Yang X, et al., 2022) [ 7 ] UPLC-MS/MS No 25–8,000 4 100 2023 (Fukuda N, et al., 2023) [ 10 ] HPLC No 10–5,000 15 100 2023 (Yasu T, et al., 2023) [ 11 ] HPLC No 0.25–10 22.3 50 2023 (De Gregori

Open access

. The previously developed methods [ 5–11 ] provide assasys in bulk and pharmaceutical forms, they are not suitable for plasma assays and their sensitivity is not enough for bioanalytical studies. Other MS methods; LC-MS/MS [ 12 , 13 , 15–17 ] and UPLC

Open access