Search Results

You are looking at 111 - 120 of 889 items for :

  • "reference materials" x
  • Refine by Access: All Content x
Clear All

Abstract  

A new application of neutron transmutation doping is described. The method is useful to prepare graded zinc contents in highly pure copper materials. The research reactor BER II at the Hahn-Meitner-Institute, Berlin served as a neutron source. The zinc content produced in the samples was analyzed by determining the 65Zn-activity via gamma-spectrometry. Simultaneously irradiated flux monitors were used to determine the neutron flux density. Since cylindrical sample geometries are favorable for a reference material application in optical emission (OE) spectroscopy, the spatial distribution of the induced activity in a cylinder with a diameter of 8 mm and a length of 35 mm was investigated.

Restricted access

Abstract  

The centification of standard reference materials is of fundamental importance for environmental scientists to proceed with their own quality control programs or calibration procedures. As part of the National Institute of Standard and Technology (NIST) program, we participated in the certification of a hazardous waste material. Our efforts concentrated on judiciously using thermal and epithermal neutron activation analysis in conjunction with Compton suppression techniques. We have demonstrated that besides lowering the detection limit for several elements usually not reported by conventional NAA, Compton suppression is ideally suited to substantially reduce certain spectrla interferences. A detailed comprehensive study was undertaken using this method to highlight which isotopes can be most favorably used.

Restricted access

Abstract  

Instrumental neutron activation analysis was applied to the determination of the elements Na, K, Br, As, Rb, Zn, Co, Fe and Sc in Brazilian rice samples and in biological standards. Hg and Se concentrations were determined by using a simple radiochemical separation. The chemical procedure was carried out by means of distillation of Hg and Se in HBr medium and subsequent precipitation of selenium by sodium metabisulfite and mercury by thioacetamide. The accuracy of the instrumental and radiochemical methods was evaluated by means of analysis of the Reference Materials NBS-Bovine Liver, Bowen's Kale and NBS-Rice Flour.

Restricted access

Abstract  

The instrumental neutron activation analysis technique (INAA) was used for homogeneity tests and certification analyses of the coal fly ash reference material ECO prepared at the Institute of Radioecology and Applied Nuclear Techniques (IRANT), Koice, Czechoslovakia. The relative standard deviations due to inhomogeneity were found to be <3% for 19 elements including for sample weights about 50 mg. The results of determination of the elements Al, As, Ba, Ca, Ce, Co, Cr, Cs, Dy, Eu, Fe, Ga, Hf, In, K, La, Mn, Mo, Na, Nd, Ni, Rb, Sb, Sc, Sm, Sr, Ta, Th, Ti, U, V, W, and Zn, were compared with the IRANT certified or information values. Inference was made on the reliability of the IRANT specified values for the element contents.

Restricted access

Abstract  

The paper describes a destructive neutron activation procedure especially set up for the determination of low levels of iridium. Only a few steps are required after irradiation, namely sample dissolution, noble metals adsorption on an ion-exchange column, removal of interfering radionuclides and counting. Successively iridium is removed from the column and the chemical yield evaluated. The method has been used for the determination of iridium in a large variety of standard reference materials, including materials of geological, biological and technological origin, with iridium levels ranging from about 0.005 to 18 ng/g. Results, given as the average of three or more independent analyses, and relative standard deviations, are reported and discussed. Average precision is about 8%, and the sensitivity is 0.004 ng.

Restricted access

Abstract  

Homogeneity study is one of the steps in reference material, RM, characterization. Due to its inherent characteristics, Instrumental Neutron Activation Analysis, INAA, is an analytical technique of choice for homogeneity testing. An interesting possibility is the use of complementary gamma ray photopeaks to confirm INAA homogeneity test results. In this study, the use of the complementary gamma ray photopeaks of 110mAg, 82Br, 60Co, 134Cs, 152Eu, 59Fe, 140La, 233Pa (for Th determination), 46Sc and 75Se radionuclides was investigated in the between bottle homogeneity study of a mussel candidate RM under preparation at IPEN–CNEN/SP. Although some photopeaks led to biased element content results, the use of complementary gamma ray photopeaks proved to be helpful in supporting homogeneity study conclusions for the new RM under characterization.

Restricted access

Abstract  

The k 0 parametric neutron activation analysis has been applied since 1995 in the Radiochemical Sector/CDTN, Belo Horizonte, Brazil. Several certified reference materials were studied with the aim of analysing biological samples. This work is related to an IAEA co-ordinated research project whose goal is to make a survey of the exposures to metals related to occupational diseases. It has been conducted by CDTN and government departments of health. The hair samples as bioindicators were donated by galvanising factory workers in Belo Horizonte. This city and surrounding area are important industrial centres and that industry is responsible for the majority of patients who look for medical assistance because of metal contamination. The Al, Co, Cu, Cr, La, Mn, Sb and V concentrations determined in the workers' samples suggest endogenous contamination.

Restricted access

Abstract  

A set of certified Reference Materials was prepared consisting of four natural agricultural soils with normal (n) and elevated (e) levels of element contents: CRM 7001 Light Sandy Soil (n), CRM 7002 Light Sandy Soil (e), CRM 7003 Silty Clay Loam (n), and CRM 7004 Loam (e). In these materials, certified and/or information values of the total contents of the elements As, Ba, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, V and Zn, and their fractions extractable by aqua regia, boiling and cold 2M nitric acid were derived from an interlaboratory comparison in which 28 laboratories participated. Highly precise and accurate procedures of instrumental neutron activation analysis (INAA) were employed for homogeneity testing and also for certification of the total element contents. For comparation purposes, NIST SRM-2704 Buffalo River Sediment was analyzed by INAA, as well. The INAA results obtained compared very well with the certified and/or information values for four soil CRMs and also with NIST values for SRM-2704. From this agreement, a very high reliability of the new soil CRMs can be inferred.

Restricted access

Abstract  

Recently, the interest in quantitative determination of rare earth elements has grown considerably, especially in connection with the space programs. There has also been a need for quantitative methods for rare earth element determination in different matrices at the National Bureau of Standards. We have therefore applied some of our earlier qualitative investigations with di(2-ethylhexyl) orthophosphoric acid (HDEHP) to separations of these elements for their subsequent quantitative determination. The rare earth elements in NBS Standard Reference Material 480, Trace Elements in Glass, a sodium glass to which 61 trace elements, including the thirteen naturally occurring rare earths, were added, have been determined by neutron activation analysis with a chemical separation using a column (11 cm×40 cm) of “Corvic” powder [poly(vinyl chloride-vinyl acetate)] loaded with HDEHP and operated at a constant temperature. Since our earlier solvent extraction studies with HDEHP had shown perchloric acid to be the most favorable of three acids (HCl, HNO3, HClO4) for rare earth separation, we established the best operating conditions (e. g. time, flow, acid concentration, etc.) using this acid. A detailed description of the separations procedure and the quantitative results will be discussed.

Restricted access

Abstract  

A fast (14-MeV) neutron activation analysis procedure was employed to directly measure mass fractions of oxygen in coal samples. The procedure demonstrated sufficient precision and accuracy to determine a relative change of about 5% or more, in the oxygen mass fraction of about 12%. The procedure was applied to test samples of the newly developed SRM 1632c Trace Elements in Coal (Bituminous). The samples had been stored at three conditions: in liquid nitrogen vapor and at room temperature in the original containers packaged under argon, and for accelerated aging at 50 °C open to air. Following six months storage increments, duplicate samples of each of twelve bottles of the SRM were measured for each storage condition. In addition each sample was processed through ten separate analytical runs yielding a total of some 720 measurements per storage duration. Oxygen was determined by comparison to a primary standard potassium dichromate and the accuracy of the method was assessed through the analysis of replicate samples of three reference materials that are certified for oxygen content. The initial 6-months test period indicated uptake of oxygen in the open-air storage.

Restricted access