Search Results

You are looking at 1 - 10 of 11 items for

  • Author or Editor: Bálint Baranyai x
  • Refine by Access: Content accessible to me x
Clear All Modify Search

Abstract:

This paper proposes the application of energy efficient, low tech (passive) building design strategies and concepts in an industrial facility case study, in order to create a building with high efficiency and comfort within the boundaries of a tight investment cost. The planning process is supported by dynamic thermal and daylight simulations. Two versions were considered, a conventional industry building and a low tech one with climate zone based space organization. According to the evaluation of thermal and visual comfort as well as energy demand the selected version with the innovative passive concept delivered considerably better performance. According to the constructor’s concept, the reference building had to be placed by minimal adaptation on the new site. After considering and calling this concept into question, a new ‘energy design’ concept was elaborated at the sketch planning level. The new concept was compared with the reference building and a quantified, simulation assisted evaluation was provided about the cases. Since there was an essential improvement in comfort and energy level and, in addition, at architectural standard, the constructor could have been convinced to accept the new concept.

Open access

Abstract

Natural and man-made disasters are vital issues that led to the increasing number of migrants, many of them stayed displaced for decades this requires more permanent dwellings. The main aim of the study is to investigate the impact of the bottom-up construction method on developing migrant’s shelters energy and thermal comfort performance. Dynamic simulation tool Indoor Climate and Energy (IDA ICE 4.8) has been used to assess nine different scenarios. The results quantified that the annually delivered energy and thermal comfort accepted hours of proposed scenario nine (S9) is better compared to base-case scenario one (S1) by 63% kWh and 4,215 h respectively. Methodologies and results of this paper can be adopted and applied for various places of the world affected by migration issue.

Open access

Abstract

There are several outdoor microclimatic simulation software tools in use. The current research aims to identify some of the most prominent computer-based tools based on their capacity of predicting a significant number of variables and compare them in order to establish their differences. This article provides an overview of the applications of computational fluid dynamics in outdoor performance simulation, focused on three topics: general criteria, specific outputs, strategies, and elements can be investigated by the tool. The results have shown that ENVI-met tool is capable of predicting and simulating the set microclimate variables.

Open access

Abstract

Numerical research in the context of urban in a humid continental climate zone is still limited. The aim of modeling the case study is to assess the performance of outdoor thermal comfort parameters and investigate their capabilities in achieving the outdoor thermal comfort. A computer-based tool is used to quantitatively study the outdoor thermal comfort and its weather parameters. The parameters have been analyzed using ENVI-met tool and then compared against different comfort scales like relative humidity comfort scale, the predicted mean vote scale as well as other scales and standards. The results have shown that the average predicted mean vote value is +4 (very hot), the average air temperature is hot, the average wind speed is light breeze and the relative humidity falls within the comfort range. However, street orientation, shading, water bodies and plantation play a significant role in increasing and decreasing the outdoor thermal comfort.

Open access

Abstract

The relationship between water body (fountains) scale and climate parameters like wind speed, air temperature, relative humidity, as well as thermal comfort index was modeled and analyzed via Envi-met code. Taking the water impact and factors analysis as a research object, the factors mainly discussed in this research are square area to water-body area ratio and the location of the water element. However, the computational fluid dynamics simulations were conducted on the following scenarios: 3% (original base case), 6%, and 9% of the total square's area, then the outputs of the two simulation results were compared to the original base case. The results revealed that water scale has a slight effect on the micro-climate of the built environment in the summertime in moderately warm-wet climate zone. However, it is beneficial to adjust temperature and humidity in public spaces of central European cities. Nonetheless, the main aim of this paper is to quantitatively investigate the impact of the water bodies on the urban weather parameters and human thermal comfort under the influence of different scale ratios in Pecs-Hungary.

Open access

Abstract

As streets cover almost twenty-five percentages of the urban open spaces, designing streets is a vital issue in creating thermal comfort for urban environmental design. The geometry of the street (height/width ratio) as well as orientation directly influences the airspeed, solar access in urban canyon and as a result thermal comfort at the pedestrian level. This study examined the street geometry case study's scenarios with different street geometries and investigates its effects on outdoor thermal comfort as well as the weather parameters. However, according to the matrix assessment conducted by the author, the vast street canyons (height/width=0.65 m/14.5 m with an orientation parallel to the prevailing wind direction achieved the best results. Nevertheless, the aim of this paper is to investigate the impact of street canyon geometry on outdoor thermal comfort and its parameters in the summertime using numerical modeling.

Open access

Abstract

As it is clear, worldwide buildings are the largest consumer of the final energy consumption. In Algeria, it has been reported that 33% of the overall energy consumption was attributed to buildings. This is due to the design and constructional techniques of the residential buildings, which do not address the local climatic condition. To assess this situation, the study is focused on analyzing the existing residential buildings in Algeria, in terms of energy, thermal, daylight, and indoor air quality performance, using a dynamic simulation software. Typical building design in a hot and dry climate was selected. The results revealed that the existing residential buildings do not comply with the energy-efficient design standards. It was concluded that further strategies should be applied in this sector, in terms of building design, materials, and façade configuration.

Open access

Abstract:

Day-lighting studies in buildings play a major role in indoor environmental investigation and can be conducted at the early stages of building design. Window position significantly affects day-lighting performance. This paper assessed the impacts of the window position on the visual comfort through two main factors; daylight factor and light uniformity in the hot and dry climate zone. In this study different window positions have been examined to achieve optimal visual comfort, using a dynamic simulation through Vi-suit plugin for Blender 3D software that controls the external application Radiance software. The results revealed that the window position at sill start from 1.4 m of a room characterized by (4.30 m × 3.00 m × 3.00 m) is the best compromising solution that complies with the daylight factor and light uniformity standards in the indoor environment. The findings of this study provide a more detailed and comprehensive analysis of the window design for architects/designers in the early building design stages in the hot and dry climate region.

Open access
Pollack Periodica
Authors:
Mohammad Reza Ganjali Bonjar
,
Kristóf Roland Horváth
,
Bálint Baranyai
, and
István Kistelegdi

Abstract

The purpose of this research is the application of a passive design strategy for office buildings, the wall-window-ratio optimization under moderate climate. A simplified thermal and lighting simulation model of an office research building served as reference testbed for thermal comfort, daylight factor and illuminance as well as heating, cooling and lighting energy demand assessment. These six performance types of similarly oriented room groups are evaluated via a self-developed weighting process to determine the orientation dependent optimal wall-window-ratio of all room groups. This multi objective optimization applies in a broad range of office buildings under moderate climate.

Open access
Pollack Periodica
Authors:
Mohammad Reza Ganjali Bonjar
,
Bálint Baranyai
,
Kristóf Roland Horváth
, and
István Kistelegdi

Abstract

The aim of this paper is to present a solution for optimizing the operation of the Szentágothai Research Center. This building has several different functions at a high degree, so it can represent most of the difficulties in achieving an ideal level of operation energy consumption while assuring an adequate comfort level.

As a first stage of a generic office building optimization research, a monitored reference building of common type was chosen. Various active operation optimization experiments were carried out. The successive reduction of operation intensity and schedules resulted in 63.3% operation energy savings. The results provide considerable potential in generic office design applications.

Open access