Abstract  

In this paper the temperature calibration of a Mettler Toledo DSC27HP high-pressure DSC for measurements in an ammonia atmosphere is described. Measurements were performed on the melting process of three reference substances in golden crucibles: indium, tin and lead. The procedure described by the German Society for Thermal Analysis and Calorimetry, GEFTA, was applied: to correct for temperature gradients in the DSC-cel extrapolated onset temperatures of the endothermic melting peaks were measured as a function of heating rate to find by extrapolation the extrapolated onset temperature at zero heating rate, which should be a temperature corrected for temperature gradients. However, measurements performed at different pressures (between 1.5 and 8.4 bar) showed that the evaluated extrapolated onset temperatures at zero heating rate decreased with increasing pressure. This observation cannot be explained by the known dependence of melting temperatures on pressure. Therefore pressure dependence of the extrapolated onset temperatures must be caused by experimental issues. It is assumed that, although the results were extrapolated to zero heating rate, results are still influenced by temperature gradients in the DSC-cell. As a mean value, the extrapolated onset temperatures at zero heating rate decreased by 0.053�C when the pressure was raised by 1 bar. Since the software package does not allow for the pressure dependence of calibration parameters, measurement results must be corrected manually for this effect.

Restricted access

Abstract  

The heat capacity calibration ‘constants’ of a commercial MTDSC system (TA 3100) were determined in a variety of experimental conditions. For a given modulation frequency, the calibration constants are the same within a few percents for different temperatures, and over a wide range of modulation amplitudes and scan rates. This variation decreases below 1% if hidden instrumental constraints are taken into account, which are related with the capability of the control system to achieve the desired temperature program. On the other hand, the calibration constant changes substantially with the period, and takes anomalously high values for the short modulation periods (20+40 s). Rules to optimize the accuracy of the system are given.

Restricted access

Abstract  

The behaviour of Ni−Fe−Ni sandwich material was investigated in air atmosphere up to 850°C with the NETZSCH microbalance TG 209. The aim was to determine if this substance is suitable for calibration. The results show that nickel-iron-nickel-bimetal makes it possible to calibrate thermobalances whilst expending a minimum of time and effort.

Restricted access

It was found that quantitative and qualitative indices of the sweet corn yield correlate with the nitrate nitrogen content of the upper soil layer (0-30 cm). As no correlation was established between the nitrate nitrogen content of the lower layers and the sweet corn, the conclusion was drawn that the quantity of sweet corn yield is determined even before its roots reach deeper down than 30 cm and the nitrogen content of the lower layers could affect the sweet corn.  Depending on the NO 3 -N content of the soil before fertilization the maximal corn ear mass achievable with fertilization may vary. In the study the same yield could not be accomplished in the case of the lowest soil nitrogen concentration (2.9 mg NO 3 -N/kg) with the highest fertilizer rate (200 kg N/ha) - but probably irrespective of any amount of fertilizer - as on the soil of 4.6 mg NO 3 -N/kg. In the case of the poorly supplied soil the fertilization curve becomes flat sooner or turns negative. The phenomenon that, regarding various soils, the maximal yield achievable on soils with good production features with fertilization is higher than in the case of soils having worse features, is well-known. That this fact is also valid in the case of the same soils was expected after calibration experiments carried out with winter oilseed rape and beet root, but it has not been proven for sweet corn as yet.  The results also showed that the grain dry matter production of sweet corn per hectare can still be enhanced with the increase in the soil's nitrogen supply, even if the corn ear does not grow.  The presented calibration curves show - in the range of 2.9-4.6 mg NO 3 -N/kg soil - how much corn ear and grain dry matter produce are expected on soils with differing nitrogen supply, distributing 0-200 kg nitrogen fertilizer in spring.

Restricted access

Abstract  

A simple method for the on-line calibration, in which both the heat transfer coefficient and the heat capacity of the reactor contents are determined, is described for laboratory scale heat transfer calorimeters. The calorimeter is operated in the isoperibolic mode for the calibration and a constant power is supplied to a resistor placed inside the reactor. The reactor heat balance differential equation is used to produce a set of linear simultaneous equations with each data acquisition cycle giving one equation. The heat transfer coefficient and the heat capacity are obtained from this set of equations by linear least squares. The application of the calibration procedure is illustrated by experiments in which the heat of reaction is determined on-line fora simulated reaction with first order kinetics and for the hydrolysis of acetic anhydride.

Restricted access

Abstract  

Micro-thermal analysis (μTATM) is a technique in which thermal analysis is performed on surfaces of test specimens on a small (ca. 2×2 μm) scale. Like any thermal analysis technique, interpretation of results benefits from accurate temperature information and knowledge of the precision of the resultant measurement. However, temperature calibration for such methods is more challenging than with its macro relatives since the calibrant comes into direct contact with the AFM sensor. This paper describes suitable calibration procedures for different types of transitions namely for first order transitions (melting points) and for glass transition temperatures using organic chemicals and polymers.

Restricted access

adjust the outputs to evaluate the accuracy of a model's estimations. This process can be improved by narrowing down the most influential input parameters using statistical methods such as sensitivity analysis [ 10–12 ]. However, the calibration of

Restricted access

Abstract  

Several reference materials and associated reference values have been recommended for the purposes of calibration and/or validation of differential scanning calorimetry (DSC). However, issues of available sample purity, reference-property value accuracy, and potential undesired reactions between reference materials and the materials used for sample pans have not been considered sufficiently in some of the recommendations of property values for the materials. These limitations attenuate greatly the usefulness of many of these reference material recommendations. Indeed, the state of uncertainty regarding true reference property values can be shown to be a limiting factor in the uncertainty of measurements made with DSC. NIST has certified the temperatures and enthalpies of fusion of two new Standard Reference Materials, SRMs 2234 and 2235, in order to help alleviate some of the difficulty.

Restricted access

Instrumentation and calibration of the Calvet calorimeter

Enthalpy of solution of PrBr3 at standard conditions

Journal of Thermal Analysis and Calorimetry
Authors: Beata Salamon, Jan Kapała, and Marcelle Gaune-Escard

pure for analysis), PrBr 3 was prepared before [ 2 ]. The metallic gallium (Aldrich 99.99% trace metals basis) was used as a reference material. The calibration of thermocouple were done for two temperature points: melting point of water and melting

Open access

Abstract  

A number of compounds are investigated for DSC calibration during cooling. Adamantane and Zn show fast reversible transitions and can be applied both for temperature and for heat calibration. A third compound, namely 4,4′-azoxyanisole, has a liquid crystal to isotropic liquid transition at 409 K. This compound can be used for temperature calibration. Heat calibration with this compound is more problematic because of the small heat effect and the construction of the baseline. Two other compounds, namely Hg and Pb, show a slight undercooling. Nevertheless they can be used for heat calibration, and possibly also for temperature calibration during cooling.

Restricted access