Search Results

You are looking at 1 - 8 of 8 items for

  • Author or Editor: I. Czakó-Nagy x
Clear All Modify Search

Abstract  

The 57Fe Mössbauer spectrum of Kaba (Hungary) meteorite was recorded at room and at liquid nitrogen temperatures. The evaluation of the spectrum showed that the iron containing components of the Kaba meteorite are magnetite, maghemite, troilite, fayalite and pentlandite.

Restricted access

Abstract  

Some Hungarian zeolites have been studied by Mössbauer spectroscopy. It has been found that Fe3+ ions substitute for Si4+ in tetrahedral position, while Fe2+ ions are chargecompensating cations in octahedral sites.

Restricted access

Abstract  

Mössbauer spectroscopy and X-ray diffractometry have been used to study Sm–Fe mixed oxides (with different SmFe atomic ratios) annealed at 550, 850, 1000 and 1250 °C. The room temperature Mössbauer spectra can be interpreted in terms of one, two or three sextets and in some cases by an additional doublet depending on the composition and the heat treatment. The sextets have been associated with SmFeO3 perovskite, Sm3Fe5O12 garnet and -Fe2O3 hematite. These results are in agreement with those of X-ray diffractometric measurements, which give a clear, evidence of the presence of these phases.

Restricted access

Abstract  

A stacking Mössbauer technique, MMS has been applied for studying thin surface layers. The surface layers formed on the57Fe film in aqueous solutions of corrosion inhibitors, such as zinc phosphate and barium metaborate, and in distilled water was studied by this method. It has been found that the corrosion is much slower in the presence of zinc phosphate and barium metaborate. XPS analysis suggests the formation of a mixed iron zinc phosphate on the surface of the57Fe film after corrosion in a zinc phosphate solution.

Restricted access

Abstract  

A special Mössbauer technique, MMS has been used for the study of corrosion on the surface of57Fe layers, under two types of organic coatings. The corrosion processes were followed by the Mössbauer spectra.

Restricted access

Abstract  

The effect of ion-beam irradiation on the composition and structure of some Co–Sn electrodeposits has been studied by Mössbauer spectroscopy. A transformation of dissolved tin and cubic CoSn to -Co3Sn2 was observed.

Restricted access

Abstract  

The effect of Xe+ irradiation and that of subsequent annealings on Fe/Sn bilayer have been studied by119Sn conversion electron Mössbauer spectroscopy. It seems that the effectiveness of ion-beam mixing is comparable to the thermal treatment of the bilayer.

Restricted access
Orvosi Hetilap
Authors: Zoltán Zsolt Nagy, Huba J. Kiss, Ágnes I. Takács, Kinga Kránitz, Cecília Czakó, Tamás Filkorn, Árpád Dunai, Gábor L. Sándor and Illés Kovács

Bevezetés: A szürkehályog-műtétek eredményeinek javítására kifejlesztett femtolézer-asszisztált szürkehályog-műtétek tökéletesítésére nagy energiák összpontosulnak. Célkitűzés: A femtolézer-asszisztált szürkehályog-műtétek során alkalmazott új, 2.16-os vezérlőszoftverrel és a módosított kezelési maszkkal (SoftFit®) nyert tapasztalatok értékelése. Módszer: A 2.16-os szoftvert és az új kezelési maszkot 100 páciens 100 szemén alkalmazták femtolézer-asszisztált szürkehályog-műtétek során. Eredmények: A megújult rendszerrel a femtolézeres előkezelés 45–60 másodpercre csökkent. Az új kezelési maszk kisebb mérete könnyebb illesztést tett lehetővé akár gyermekszemen is. A maszkot rögzítő szívóerő 40–50 Hgmm-ről 16–20 Hgmm-re csökkent. A subconjunctivalis suffusio aránya 40%-ról 15–20%-ra csökkent, súlyossága mérséklődött. Szaruhártyaredők nem jelentkeztek, a szabadon lebegő capsulotomiák aránya 30%-ról 97%-ra nőtt. A lézerkezeléshez szükséges energia csaknem 50%-kal csökkent. A tervezettnek megfelelő cornealis sebek könnyen megnyithatóak és pontosan záródóak voltak. Következtetések: A SoftFit® kezelési maszk és az új szoftver a femtolézer-asszisztált szürkehályog-műtétek alkalmazási lehetőségeit bővítette, lehetővé téve a gyermekkori szürkehályog-műtétekben történő alkalmazást. A fejlesztések a módszer biztonságosságát és kiszámíthatóságát tovább növelték. Orv. Hetil., 2015, 156(6), 221–225.

Open access