The aim of this article is to study the influence of TiC/a:C protective thin film on the corrosion and mechanical properties of sandblasted/polished Ti and TiAl6V4 substrates. The electrochemical corrosion behaviors of the samples were investigated in simulated body fluid (SBF) by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques at 7.4 pH and 37 °C. The metal ion release has been quantified by inductively coupled plasma optical emission spectroscopy (ICP-OES). The experimental results obtained from different electrochemical methods, ICP-OES, and scanning electron microscopy (SEM) showed that the TiC/a:C protective coating on sandblasted implant device improves the corrosion properties of the implant material and it is able to control the metal ion release. It was also shown that the hardness of the bare implant materials is improving by four orders of magnitude with the TiC/a:C nanocomposite coating beside a moderate elastic modulus value. The highest hardness (H) of ~28 GPa ± 3 was observed in the case of the film prepared at ~38 at% Ti content. Overall, the TiC/a:C thin film has suitable electrochemical characteristics for further consideration and assessment as a protective coating.