Search Results

You are looking at 1 - 10 of 47 items for

  • Author or Editor: P. Nagy x
Clear All Modify Search

The effects of UV-C radiation on the germination rate and fungal contamination of tall fescue seeds were investigated. Samples from the same seed lot were irradiated in two different ways in two consecutive years. The seeds were irradiated with a Hg vapour lamp using different doses. In the first trial one side of the seeds was irradiated, while in the second trial a mirror was used to irradiate the whole seed surface. The results showed that various doses of UV-C irradiation had an effect on the germination rate, but there were no significant differences in germination percentage between the treatments. Differences in fungal contamination rates were observed when the seeds were irradiated on all sides. The presence of 21 fungal genera was identified on the seeds, the saprotrophic fungi Alternaria, Rhizopus and Penicillium being dominant.

Restricted access

We examined effects of UV and visible light irradiation on mycelial growth and sclerotium formation of Sclerotinia sclerotiorum. The irradi­ation with UV had no effect on the production of sclerotia. However it had strong inhibitory action on the growth of mycelia. In cultures of the fungus irradiated with yellow and green light more but small sclerotia developed mainly in the perimeter of culture at the time of irradiation and between this circle and the wall of Petri dishes. In cultures irradiated with red and blue light, a few, but large sclerotia developed.

Restricted access

Abstract  

The G-1 intercomparison is one of the first undertakings of the International Atomic Energy Agency for the investigation of the performance of the routinely used evaluating programs for gamma ray spectra of semiconductor detectors. The details and the conclusions of this procedure are presented.

Restricted access
Authors: J. Solymosi, P. Zagyvai and L. Nagy

Abstract  

A quantitative method for the analysis of -emitters in infinitely thin and thick samples was described in Part I. The calculation of errors in intensity, intensity ratio and activity concentration is discussed here in detail. Different definitions of detection sensitivity are compared and evaluated on the basis of the relative statistical error associated therewith. Dependence between the relative error of the net signal and the required measurement time is deduced and illustrated.

Restricted access
Authors: J. Solymosi, P. Zagyvai and L. Nagy

Abstract  

A method for determining bulk or surface activity concentration of -emitters in infinitely thick or thin samples using energy selective detectors without any prior chemical separation or qualitative analysis was introduced in Part I. In addition to that method, a correction procedure is often required in order to compensate for the -sensitivity of the -detector. A system or two — preferably identical —detectors positioned to the front and rear side of a sample has been established. The rear side detector is shielded against -radiation. The -response of both detectors is determined as a function of -energy using monoenergetic calibration standards. Response pulses are selected to form 8 or 16 energy intervals, and separate series of correction coefficients are then computed for each interval and standard energy using the ratio of the respective counts. When a sample having mixed - and -radiation is evaluated, an effective -energy is first calculated from the pulse height distribution of the rear side detector, the appropriate series of correction coefficients is selected and finally net -counts are generated from the counts of the front side detector. Sensitivities in natural and elevated -background are presented.

Restricted access
Authors: J. Solymosi, P. Zagyvai and L. Nagy

Abstract  

The activity concentration of bulk and surface samples contaminated with -emitting radioisotopes is difficult to measure without the a priori knowledge of the nature of the non-gamma emitting components. Beta-emitters cannot be identified from any measured spectral distribution. The counting efficiency of the measuring system changes significantly with -energy so it cannot be assumed to have a single value obtained with a standard source with known energy. Application of an energy selective -detector is introduced for determining bulk and surface activity concentration. Samples of infinitely thick or infinitelythin nature are to be prepared. The distribution of -energy deposited in the detector is registered as counts in 8 or 16 energy intervals. No information is needed on the qualitative composition of the sample. Normalised integral distributions (intensity ratios) are derived from the count rates of the intervals. These distributions are then compared to calibrated intensity ratios obtained with suitable standard sources. An average (effective) counting efficiency is generated from this comparison by a special algorithm. Activity concentration of an unknown sample is then obtained using this average efficiency. Calibration and sensitivity data are presented for different types of bulk and surface samples.

Restricted access

Abstract  

Investigations on the disintegration rate of fission products of238U and239Pu are presented. The intensity of the - and -radiation of fission products were measured continuously in an interval of 1–1300 hours following the fission, offering the possibility for determining the general and specific characteristics of the individual fission products. A universal measuring procedure was elaborated for the rapid in situ determination of the dosimetric features of fission products, which is suitable for the accurate evaluation and prediction of external absorbed dose even in case of fission products of various origin and unknown composition.

Restricted access