Search Results

You are looking at 1 - 4 of 4 items for

  • Author or Editor: Tamás Donkó x
  • Refine by Access: All Content x
Clear All Modify Search

Atrophic rhinitis (AR) is a widespread and economically important disease of swine caused by Bordetella bronchiseptica and Pasteurella multocida . It can be controlled by vaccination. This study investigates the effect of altering the composition (adjuvants and/or addition of formalin-inactivated P. multocida toxin, fPMT) of conventional vaccines on the serological profile and on protection against AR in swine. A significantly higher B. bronchiseptica specific antibody titre was detected for vaccines with novel immunostimulants, the best being Montanide IMS 1313 (1:630 compared to 1:274 obtained with alum). The highest B. bronchiseptica antibody titre was demonstrated for a combination of B. bronchiseptica — fPMT, while PMT antibody titre was highest for monovalent fPMT (both adjuvanted with IMS 1313). The AR-specific antibodies were transmitted from dams to their offspring in similar titres and with the same hierarchy of effectiveness. After a B. bronchiseptica — P. multocida bacterial challenge, piglets from dams vaccinated with fPMT combined with B. bronchiseptica or B. bronchiseptica — P. multocida bacterins showed the lowest nasal lesions scores (4.5 and 3.2, respectively, out of a possible maximum score of 18). These combinations, both of which were adjuvanted with IMS 1313, gave the best protection against experimentally induced AR. Our results show that the adjuvant and the antigen composition of the vaccine strongly affect seroconversion, and that the AR-specific antibody titre does not necessarily correlate with the degree of protection.

Restricted access
Acta Veterinaria Hungarica
Authors:
Róbert Romvári
,
András Szabó
,
Gabriella Andrássy
,
Zsolt Petrási
,
Tamás Donkó
, and
Péter Horn

A two-way selection procedure was performed on a Landrace pig line. First the cardiac output (CO) values (6.89 ± 1.27 L/min) were estimated by ECG-gated magnetic resonance imaging (MRI) to quantify the heart performance of the boars (n = 30), then total body skeletal muscle volume (MVTB; 48.7 ± 5.17 dm 3 ) was determined applying spiral computerised tomography (CT). The relative cardiac output value (RCO) was developed, expressing the relationship between CO and MVTB. Four superior [RCO value below 6.7 dm 3 / (L * min −1 )] and one minus variant [(8.97 dm 3 / (L * min −1 )] boars were taken into breeding. The best fifteen percentage of the first generation males (n = 30) was characterised according to their RCO values. Significant difference was found between the developed performance measure of the progenies of minus and plus variant boars [8.2 ± 0.65 and 5.63 ± 0.70 dm 3 / (L * min −1 ), n = 7 and 23], respectively. Comparing the existing five progeny groups, all of the ‘HP+’ groups differed significantly from the ‘HP-’ one, where the largest heart performance contrast found was 3.2 dm 3 / (L * min −1 ). Based upon the results, the selection is being continued on a larger population.

Restricted access

Abstract

The non-invasive diagnostic methods represent a new branch of insect diagnostics, which can provide novel information especially about insects with hidden lifestyle. Computed tomography (CT) is one of the most useful non-destructive techniques allowing for both qualitative and quantitative assessments. The aim of the present study was to attain entomological information through the implementation of CT imaging, hence contributing to the spread of non-invasive imaging in entomological research. Through monitoring the development of wood-dwelling cerambycid larvae in beech branches, we point out some outputs applicable in entomological studies, which originate from CT image post-processing. We present findings on the location, and size of specimens of some hidden arthropods, as well as cavities formed by them, stemming from the maximum and minimum intensity projections, windowing, 3D-reconstruction, or virtual endoscopy, as steps of the imaging. In summary, it is expected that our findings contribute to a wider recognition of the entomological information that can be gathered from these non-invasive imaging techniques.

Open access
Orvosi Hetilap
Authors:
Gábor Bajzik
,
Anett Tóth
,
Tamás Donkó
,
Péter Kovács
,
Dávid Sipos
,
Attila András Pandur
,
Mariann Moizs
,
Janaki Hadjiev
,
Imre Repa
, and
Árpád Kovács

Absztrakt:

Bevezetés és célkitűzés: Az ionizáló sugárzást használó keresztmetszeti képalkotó modalitások alkalmazása során kiemelt szerepe van a pácienseket érő sugárdózis mennyiségének. A betegeket érő sugárterhelés csökkentésére fókuszálva fontos felmérni a különböző dóziscsökkentő technikák adta lehetőségeket a sugárvédelem optimális megvalósítása céljából a képminőség minél magasabb szinten tartása mellett. Módszer: Kutatásunk során az intézetünkben használt iteratív képrekonstrukciót (SAFIRE) és a szűrt visszavetítéses rekonstrukciót (FBP) alkalmazó CT-berendezések sugárterhelését és képminőségét hasonlítottuk össze. Vizsgálatunkban prospektív módon 2017. február–április intervallumban 105 beteg képanyagával dolgoztunk. A CT-vizsgálatok során a beteget érő effektív dózis került meghatározásra a dózis-hossz szorzat (DLP) és a dóziskonverziós együttható szorzataként. A képminőség értékeléséhez manuális terület kijelölés (ROI-) alapú adatfelvételt követően jel-zaj arányt (SNR) számoltunk. A statisztikai elemzést egymintás t-próbával és Wilcoxon-teszttel végeztük el. Eredmények: Az effektív dózis iteratív rekonstrukciót alkalmazva szignifikánsan alacsonyabb (p<0,001) volt natív és kontrasztanyagos hasi, illetve kontrasztanyagos mellkasi CT-vizsgálat esetén, továbbá a betegeket ért összes effektív dózis tekintetében is. A felvételek zajtartalma natív és kontrasztanyagos hasi CT-vizsgálat során szignifikánsan alacsonyabb (p<0,001) értékeket mutatott az iteratív rekonstrukcióval készült képek esetén. A kontrasztanyagos mellkasi CT-vizsgálatok során szignifikáns eltérés nem mutatkozott a kétféle eljárással készült képek zajtartalma között (p>0,05). Következtetés: Az ismételt CT-vizsgálaton átesett betegek körében szignifikáns dóziscsökkentés vált lehetővé az iteratív képrekonstrukció alkalmazásával, a képminőség megtartása mellett. A képek zajtartalma egy régió vizsgálatánál sem volt szignifikánsan magasabb az iteratív rekonstrukció alkalmazásakor a szűrt visszavetítéses rekonstrukcióhoz képest, így felmerül a további dóziscsökkentés lehetősége optimális képminőség megőrzése mellett. Orv Hetil. 2019; 160(35): 1387–1394.

Open access