Search Results

You are looking at 1 - 10 of 113 items for :

  • Materials and Applied Sciences x
  • All content x
Clear All

; JEOL 6380 LA, Japan). Each sample was coated with gold–palladium (Au–Pd) alloy for 30 s before the examination. For each sample, 300 fibers were measured to obtain the diameter distribution by using Image J software. Results

Open access
Restricted access

The present paper of a series deals with the experimental characterisation of flexural toughness properties of structural concrete containing different volume of hooked-end steel fibre reinforcement (75 kg/m3, 150 kg/m3). Third-point flexural tests were carried out on steel fibre reinforced concrete beams having a cross-section of 80 mm × 85 mm with the span of 765 mm, hence the shear span to depth ratio was 3. Beams were sawn out of steel fibre reinforced slab elements (see Part I) in order to take into consideration the introduced privilege fibre orientation (I and II) and the position of the beam (Ba-a, Ba-b, Ba-c) before sawing (see Part I). Flexural toughness properties were determined considering different standard specifications, namely the method of the ASTM (American Standards for Testing Materials), the process of the JSCE (Japan Society of Civil Engineering), and the final proposal of Banthia and Trottier for the post cracking strength. Consequently, behaviour of steel fibre reinforced concrete was examined in bending taking into consideration different experimental parameters such as fibre content, concrete mix proportions, fibre orientation, positions of test specimens in the formwork, while experimental constants were the size of specimens, the type of fibre used and the test set-up and test arrangement.

Restricted access

), Assessing the effect of design parameters on optimal size of isolated PV systems for residential utilizations . In: IEEE System Integration (SII), 2014 IEEE/SICE International Symposium , Tokyo, Japan, 2014.12.13–2014.12.15. pp. 234 – 239 ., (ISBN: 978

Open access

. Kohl , T. , D. Bächler , L. Rybach ( 2000 ). Steps towards a comprehensive thermo-hydraulic analysis of the HDR test site Soultz-sous-Forêts . Proceedings of the World Geothermal Congress 2000, Kyushu-Tohoku, Japan, May–June 2000, 2671 – 2676

Restricted access

J. Catalão , “ Computer simulation of wind power systems: power electronics and transient stability analysis ,” in Int. Conf. Power Sys. Trans. , Kyoto , Japan . 2009 . [3] B. Sun , H. Zhengyou , Y. Jia , and K. Liao , “ Small

Open access

), Effect of frequency ratio on the force coefficients of a cylinder oscillated in a uniform stream . Proc. 7th JSME-KSME Thermal and Fluids Engineering Conference, Sapporo, Japan, on CD ROM, pp.1–4, Paper No. L132. [30

Restricted access
Resolution and Discovery
Authors: Svetlana Jovanovic, Olaf C. Haenssler, Milica Budimir, Duška Kleut, Jovana Prekodravac, and Biljana Todorovic Markovic

10 mm 2 SDD detector, PentaFET Precision INCA X-act, 125 eV resolution, which detects elements from Be to Pu). Absorption measurements were performed at UV–visible UV-2600 Spectrophotometer (Shimadzu Corporation, Tokyo, Japan) from 200 to 800 nm

Open access

Agrobiological Measurements in Japan. The most cited recent paper was in 2013 titled as “When yield gaps are poverty traps: The paradigm of ecological intensification in African smallholder agriculture” written by Tittonell P. and Giller K.E. Table 4. Top 10 most

Open access

method for autogenous shrinkage was explained in detail in The Japan Concrete Institute 1988. Later on Brooks et al., [ 10 ] elaborated a most reliable method for the same and concluded that MK at higher replacement level dented the basic creep, drying

Open access