Search Results

You are looking at 1 - 10 of 98 items for :

  • "Differential scanning calorimeter (DSC)" x
  • All content x
Clear All

. The non-isothermal crystallization behaviors of typical isotactic P4MP1 were investigated by using differential scanning calorimeter (DSC) and wide angle X-ray diffraction (WAXD) in this study. The crystallization kinetics was adequately described via

Restricted access

. Experimental procedures An Infrared spectroscopy (IR) spectrum was obtained using a Thermo-Nicolet Avatar 370 of solid sample. Differential scanning calorimeter (DSC) measurements were performed on a Mettler Toledo, DSC 822 on 278 and 283 K min −1

Restricted access

Introduction Differential scanning calorimetry is an established technique for characterising the thermal properties of materials. Experiments involving a differential scanning calorimeter (DSC) generally involve the use of

Restricted access

to 20 RPM with LV4 cylindrical spindle. Thermal properties Thermal properties were analysed by differential scanning calorimeter (DSC) (NETZSCH DSC 3500) previously calibrated with indium. The samples (14.0 ± 1 mg) were hermetically closed in concave

Open access

solvent and TMS as the internal standard. Heat flows as a function of temperature and time for nonisothermal reactions of DGEBA/1.0GPPI and DGEBA/PAN4 were registered with a Perkin Elemer differential scanning calorimeter (DSC-7) which was previously

Restricted access

from a crystalline state to a gel can be measured using a differential scanning calorimeter (DSC). This temperature range is usually called the gelatinization temperature range (Δ T ) and, its values depend on starch type and granule population

Restricted access
Journal of Thermal Analysis and Calorimetry
Authors: Hou-yin Zhao, Yan Cao, Song P. Sit, Quentin Lineberry, and Wei-ping Pan

Differential scanning calorimeter (DSC) was performed with a TA 2920 DSC analyzer. About 3–6 mg of the sample was placed in an aluminum pan with a pinhole lid and was heated to 600 °C at a rate of 10 °C min −1 under a nitrogen flow (purity > 99.999%) of 40 mL

Restricted access

found in a pure crystalline phase and consequently it is a good reference system. Experimental The enthalpies of oxidative leaching of pyrite were measured using a differential scanning calorimeter (DSC C80, Setaram) equipped

Restricted access

temperatures on the non-isothermal crystallization behavior, and the melting characteristics and the β -PP content of the β -nucleated PP/PET blends were investigated by differential scanning calorimeter (DSC) and wide angle X-ray diffraction (WAXD

Restricted access

. The experiments are conducted in linear temperature program and under adiabatic condition by means of differential scanning calorimeter (DSC) and accelerating rate calorimeter (ARC) to evaluate the thermal hazards and pave the way for helping other

Restricted access