View More View Less
  • 1 Pacific Northwest National Laboratory Richland, WA 99352, USA
  • | 2 Pacific Northwest National Laboratory Richland, WA 99352, USA
  • | 3 Pacific Northwest National Laboratory Richland, WA 99352, USA
  • | 4 Pacific Northwest National Laboratory Richland, WA 99352, USA
  • | 5 Pacific Northwest National Laboratory Richland, WA 99352, USA
Restricted access

Summary  

The determination of transuranic (TRU) content in nuclear wastes, reactor materials, process solutions, and various other matrices is required in support of material assessment, environmental restoration, and waste processing activities. We have found that direct measurement of TRU is possible using surface passivated ion implanted planar silicon diode detectors. The performance and durability of modern silicon diodes enables direct detection of alpha-particles, with retention of some spectral information, through small air gaps or under direct contact with liquid or solid samples. We will present results on the performance of silicon diode detectors for the determination of TRU in liquids.

Manuscript Submission: HERE

  • Impact Factor (2019): 1.137
  • Scimago Journal Rank (2019): 0.360
  • SJR Hirsch-Index (2019): 65
  • SJR Quartile Score (2019): Q3 Analytical Chemistry
  • SJR Quartile Score (2019): Q3 Health, Toxicology and Mutagenesis
  • SJR Quartile Score (2019): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2019): Q3 Pollution
  • SJR Quartile Score (2019): Q3 Public Health, Environmental and Occupational Health
  • SJR Quartile Score (2019): Q3 Radiology, Nuclear Medicine and Imaging
  • SJR Quartile Score (2019): Q3 Spectroscopy
  • Impact Factor (2018): 1.186
  • Scimago Journal Rank (2018): 0.408
  • SJR Hirsch-Index (2018): 60
  • SJR Quartile Score (2018): Q2 Nuclear Energy and Engineering
  • SJR Quartile Score (2018): Q2 Pollution

For subscription options, please visit the website of Springer Nature.

Journal of Radionalytical and Nuclear Chemistry
Language English
Size A4
Year of
Foundation
1968
Volumes
per Year
4
Issues
per Year
12
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0236-5731 (Print)
ISSN 1588-2780 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
May 2021 0 0 0
Jun 2021 0 0 0
Jul 2021 0 0 0
Aug 2021 0 0 0
Sep 2021 0 0 0
Oct 2021 1 0 0
Nov 2021 0 0 0