Authors:
S. Yang State Key Lab of Advanced Technology for Platinum Metals, Kunming Institute of Precious Metals, Kunming, 650106, China
School of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming, 650092, China

Search for other papers by S. Yang in
Current site
Google Scholar
PubMed
Close
,
X. Chen State Key Lab of Advanced Technology for Platinum Metals, Kunming Institute of Precious Metals, Kunming, 650106, China

Search for other papers by X. Chen in
Current site
Google Scholar
PubMed
Close
,
P. Zhen School of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming, 650092, China

Search for other papers by P. Zhen in
Current site
Google Scholar
PubMed
Close
,
Q. Ye State Key Lab of Advanced Technology for Platinum Metals, Kunming Institute of Precious Metals, Kunming, 650106, China

Search for other papers by Q. Ye in
Current site
Google Scholar
PubMed
Close
,
X. Xie School of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming, 650092, China

Search for other papers by X. Xie in
Current site
Google Scholar
PubMed
Close
, and
W. Liu State Key Lab of Advanced Technology for Platinum Metals, Kunming Institute of Precious Metals, Kunming, 650106, China

Search for other papers by W. Liu in
Current site
Google Scholar
PubMed
Close
Open access

Summary

A simple and rapid HPLC method using a photodiode array (PDA) detector for the analysis of 3-hydroxycarboplatin and its related complex has been established for the first time. Separation of 3-hydroxycarboplatin and 3-hydroxy-1,1-cyclobutanedicarboxylic acid (3-HO-cbdca) was carried out on a Phenomenex ODS3 column using an aqueous solution containing 50 mM ammonium acetate and 5 mM sodium 1-octanesulfonate as the mobile phase. The flow rate was 0.8 mL min−1, the column temperature was 40°C, and the detection wavelength was 230 nm for 3-hydroxycarboplatin and 220 nm for 3-HO-cbdca. Different analytical performance parameters such as precision, accuracy, linearity, stability of the solution, specificity, limit of detection (LOD), limit of quantification (LOQ), and system suitability were determined using the Empower 2 software. The calibration curve of standard 3-hydroxycarboplatin showed good linearity (r = 0.9995) within the range 0.5–1.4 mg mL−1. The method was accurate and precise, with an average accuracy of 100.4% (RSD = 1.53%, n = 9), and the results of the system suitability test showed symmetrical peaks, good resolution (Rs), and repeatability. It can be applied to the quality control of 3-hydroxycarboplatin.

  • [1]. E. Wang C.M. Giandomenico 1999 Chem. Rev. 99 2451.

  • [2]. Y.P. Ho S.C.F. Au-Yeung K.K.W. To 2003 Med. Res. Rev. 23 633.

  • [3]. G. Momekov A. Bakalova M. Karaivanova 2005 Curr. Med. Chem. 12 2177.

  • [4]. S.V. Zutphen J. Reedijk 2005 Coord. Chem. Rev. 249 2845.

  • [5]. A.S. Abu-Surrah M. Kettunen 2006 Curr. Med. Chem. 13 1337.

  • [6]. M.A. Jakupec M. Galanski B.K. Keppler 2003 Rev. Physiol. Biochem. Pharmacol. 146 1.

  • [7]. M. Galanski 2006 Recent Patents on Anticancer Drug Discovery 1 285.

  • [8]. G. Bernhardt H. Brunner N. Gruber 2004 Inorg. Chim. Acta 357 4452.

  • [9]. A.L. Flores R. Jurado P.G. Lopez 2005 J. Pharmacol. Toxicol. Methods 52 370.

  • [10]. M.E. Bosch A.J.R. Sanchez F.S. Rojas C.B. Ojeda 2008 J. Pharm. Biomed. Anal. 47 453.

  • [11]. A. Mittal D. Chitkara N. Kumar 2007 J. Chromatogr. B 855 212.

  • [12]. D.N. Bell J.J. Liu M.D. Tingle M.J. McKeage 2006 J. Chromatogr. B 837 31.

  • [13]. Y. Vander Heyden D. Mangelings Van Brempt H. Spapen 2004 Acta Chromatogr. 14 155.

  • [14]. Z. Mrkvickova P. Kovarikova J. Klimes 2007 J. Pharm. Biomed. Anal. 43 1347.

  • [15]. Chinese Pharmacopia , 2005, p, 108.

  • [16]. S. Hann Zs. Stefanka K. Lenz G. Stingeder 2005 Anal. Bioanal. Chem. 381 408.

  • [17]. W. Zapała K. Kaczmarski 2010 Acta Chromatogr. 22 18.

  • [18]. USP, 2007, 30th edn, p, 1630.

  • Collapse
  • Expand
The author instructions are available in PDF.
Please, download the file from HERE.

 

 

Senior editors

Editor(s)-in-Chief: Kowalska, Teresa (1946-2023)

Editor(s)-in-Chief: Sajewicz, Mieczyslaw, University of Silesia, Katowice, Poland

Editors(s)

  • Danica Agbaba, University of Belgrade, Belgrade, Serbia
  • Łukasz Komsta, Medical University of Lublin, Lublin, Poland
  • Ivana Stanimirova-Daszykowska, University of Silesia, Katowice, Poland
  • Monika Waksmundzka-Hajnos, Medical University of Lublin, Lublin, Poland

Editorial Board

  • Ravi Bhushan, The Indian Institute of Technology, Roorkee, India
  • Jacek Bojarski, Jagiellonian University, Kraków, Poland
  • Bezhan Chankvetadze, State University of Tbilisi, Tbilisi, Georgia
  • Michał Daszykowski, University of Silesia, Katowice, Poland
  • Tadeusz H. Dzido, Medical University of Lublin, Lublin, Poland
  • Attila Felinger, University of Pécs, Pécs, Hungary
  • Kazimierz Glowniak, Medical University of Lublin, Lublin, Poland
  • Bronisław Glód, Siedlce University of Natural Sciences and Humanities, Siedlce, Poland
  • Anna Gumieniczek, Medical University of Lublin, Lublin, Poland
  • Urszula Hubicka, Jagiellonian University, Kraków, Poland
  • Krzysztof Kaczmarski, Rzeszow University of Technology, Rzeszów, Poland
  • Huba Kalász, Semmelweis University, Budapest, Hungary
  • Katarina Karljiković Rajić, University of Belgrade, Belgrade, Serbia
  • Imre Klebovich, Semmelweis University, Budapest, Hungary
  • Angelika Koch, Private Pharmacy, Hamburg, Germany
  • Piotr Kus, Univerity of Silesia, Katowice, Poland
  • Debby Mangelings, Free University of Brussels, Brussels, Belgium
  • Emil Mincsovics, Corvinus University of Budapest, Budapest, Hungary
  • Ágnes M. Móricz, Centre for Agricultural Research, Budapest, Hungary
  • Gertrud Morlock, Giessen University, Giessen, Germany
  • Anna Petruczynik, Medical University of Lublin, Lublin, Poland
  • Robert Skibiński, Medical University of Lublin, Lublin, Poland
  • Bernd Spangenberg, Offenburg University of Applied Sciences, Germany
  • Tomasz Tuzimski, Medical University of Lublin, Lublin, Poland
  • Yvan Vander Heyden, Free University of Brussels, Brussels, Belgium
  • Adam Voelkel, Poznań University of Technology, Poznań, Poland
  • Brata Walczak, University of Silesia, Katowice, Poland
  • Wiesław Wasiak, Adam Mickiewicz University, Poznań, Poland
  • Igor G. Zenkevich, St. Petersburg State University, St. Petersburg, Russian Federation

 

KOWALSKA, TERESA (1946-2023)
E-mail: kowalska@us.edu.pl

SAJEWICZ, MIECZYSLAW
E-mail:msajewic@us.edu.pl

Indexing and Abstracting Services:

  • Science Citation Index
  • Sci Search
  • Research Alert
  • Chemistry Citation Index and Current Content/Physical
  • Chemical and Earth Sciences
  • SCOPUS
  • GoogleScholar
  • Index Copernicus
  • CABI
  • CABELLS Journalytics

2023  
Web of Science  
Journal Impact Factor 1.7
Rank by Impact Factor Q3 (Chemistry, Analytical)
Journal Citation Indicator 0.43
Scopus  
CiteScore 4.0
CiteScore rank Q2 (General Chemistry)
SNIP 0.706
Scimago  
SJR index 0.344
SJR Q rank Q3

Acta Chromatographica
Publication Model Online only
Gold Open Access
Submission Fee none
Article Processing Charge 400 EUR/article
Regional discounts on country of the funding agency World Bank Lower-middle-income economies: 50%
World Bank Low-income economies: 100%
Further Discounts Editorial Board / Advisory Board members: 50%
Corresponding authors, affiliated to an EISZ member institution subscribing to the journal package of Akadémiai Kiadó: 100%
Subscription Information Gold Open Access
Purchase per Title  

Acta Chromatographica
Language English
Size A4
Year of
Foundation
1988
Volumes
per Year
1
Issues
per Year
4
Founder Institute of Chemistry, University of Silesia
Founder's
Address
PL-40-007 Katowice, Poland, Bankowa 12
Publisher Akadémiai Kiadó
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 2083-5736 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Feb 2024 0 104 7
Mar 2024 0 21 12
Apr 2024 0 6 7
May 2024 0 14 8
Jun 2024 0 13 10
Jul 2024 0 8 2
Aug 2024 0 0 0