Authors:
Lenche Velkoska-Markovska Ss. Cyril and Methodius University, Blvd. Aleksandar Makedonski bb, P. O. Box 297, 1000 Skopje, Republic of Macedonia

Search for other papers by Lenche Velkoska-Markovska in
Current site
Google Scholar
PubMed
Close
,
Mirjana S. Jankulovska Ss. Cyril and Methodius University, Blvd. Aleksandar Makedonski bb, P. O. Box 297, 1000 Skopje, Republic of Macedonia

Search for other papers by Mirjana S. Jankulovska in
Current site
Google Scholar
PubMed
Close
,
Biljana Petanovska-Ilievska Ss. Cyril and Methodius University, Blvd. Aleksandar Makedonski bb, P. O. Box 297, 1000 Skopje, Republic of Macedonia

Search for other papers by Biljana Petanovska-Ilievska in
Current site
Google Scholar
PubMed
Close
, and
Kristijan Hristovski Ss. Cyril and Methodius University, Blvd. Aleksandar Makedonski bb, P. O. Box 297, 1000 Skopje, Republic of Macedonia

Search for other papers by Kristijan Hristovski in
Current site
Google Scholar
PubMed
Close
Open access

Coffee is one of the most widely consumed beverages in the world. It contains many bioactive compounds, including chlorogenic acid which possesses various biological properties. In this study, in order to determine concentration of chlorogenic acid in green coffee, a reverse-phase rapid resolution liquid chromatography (RP-RRLC) method with diode-array detection (DAD) was developed. Successful separation was achieved on a Poroshell 120 EC-C18 (50 mm × 3 mm; 2.7 μm) column using acetonitrile–water with 1% phosphoric acid (10:90, v/v) as a mobile phase, at a flow rate of 1 mL/min, and with UV detection at 325 nm. The identification was made with comparison of the retention time of pure analytical standard with the retention time of chlorogenic acid in the analyzed samples. The developed method was validated using the following parameters: linearity, sensitivity, selectivity, precision, and accuracy. Excellent linearity over the range 12.33–143.50 μg/mL was achieved with R2 values greater than 0.99. The intra-day precision was validated with the %RSD values, which confirmed that the method for determination of chlorogenic acid was repeatable. The mean recovery rate of the method ranged between 97.87% and 106.67% with %RSD values lower than 1%. The limit of detection and limit of quantification values under the used chromatographic conditions were 0.29 and 0.96 pg, respectively. This method was successfully employed for quantitative determination of chlorogenic acid in green coffee samples.

Abstract

Coffee is one of the most widely consumed beverages in the world. It contains many bioactive compounds, including chlorogenic acid which possesses various biological properties. In this study, in order to determine concentration of chlorogenic acid in green coffee, a reverse-phase rapid resolution liquid chromatography (RP-RRLC) method with diode-array detection (DAD) was developed. Successful separation was achieved on a Poroshell 120 EC-C18 (50 mm × 3 mm; 2.7 μm) column using acetonitrile–water with 1% phosphoric acid (10:90, v/v) as a mobile phase, at a flow rate of 1 mL/min, and with UV detection at 325 nm. The identification was made with comparison of the retention time of pure analytical standard with the retention time of chlorogenic acid in the analyzed samples. The developed method was validated using the following parameters: linearity, sensitivity, selectivity, precision, and accuracy. Excellent linearity over the range 12.33–143.50 μg/mL was achieved with R2 values greater than 0.99. The intra-day precision was validated with the %RSD values, which confirmed that the method for determination of chlorogenic acid was repeatable. The mean recovery rate of the method ranged between 97.87% and 106.67% with %RSD values lower than 1%. The limit of detection and limit of quantification values under the used chromatographic conditions were 0.29 and 0.96 pg, respectively. This method was successfully employed for quantitative determination of chlorogenic acid in green coffee samples.

Introduction

Coffee is one of the most popular beverages in the world. The popularity of the coffee is due to its unique flavor, making it one of the most desirable and frequently consumed beverages worldwide. It has a strong historical, cultural, social, and economic importance as well [1]. Botanically, coffee belongs to the family Rubiaceae in the genus Coffea. Commercial coffee beverages are made from Coffea arabica or Coffea robusta beans or blends of them, and its quality is strictly related to the chemical composition of the roasted beans, which is affected by the composition of the green beans and post-harvesting processing conditions [2]. Typical compounds in coffee, such as caffeine, trigonelline, and chlorogenic acid, are known to influence coffee flavor, acidity, and bitterness [3]. Chlorogenic acid and its derivatives are few of the main phenolic compounds present in coffee [4]. As it is well known, the main characteristic of phenolic compounds is their ability to trap free radicals that cause degenerative diseases [5]. These compounds have antioxidant properties, which play an important role in protecting food, cells, and organs from oxidative degenerative diseases [5]. Diet rich in chlorogenic acid prevents various diseases associated with oxidative stress such as cancer, cardiovascular, aging, and neurodegenerative diseases [6]. Chlorogenic acid has an important influence on the formation of pigments, taste, and flavor of coffee beans, which determines the quality and acceptance of the beverages [6]. According to Farah et al., the concentration of chlorogenic acid has an inverse association with coffee quality, i.e., higher contents is observed in a lower quality coffee sample [7]. The concentration of chlorogenic acid in raw coffee is much greater than that in the roasted one. This suggests that the degree of roasting affects the concentration of chlorogenic acid, i.e., during roasting, degeneration of chlorogenic acid and its derivatives occur [8]. The content of chlorogenic acid in the coffee beverage depends on the species, the variety, and the processing conditions of the coffee beans [9]. The green coffee contains 5–12 g/100 g chlorogenic acid [7]. Chlorogenic acid is an ester of trans-cinnamic acid, such as caffeic acid, ferulic, and p-coumaric acid with (−)-quinic acid.

The literature revels that for quantitative analysis of bioactive compounds such as chlorogenic acid in food and beverages several techniques can be used [1012]. However, high-performance liquid chromatography (HPLC) remains one of the most common techniques which give accurate results [1, 1317]. Chlorogenic acid can be determined by HPLC applying different chromatographic conditions. The most frequently used combinations of solvents are as follows: a mixture of methanol and 0.2 mol/L acetate buffer (pH 3.6) (15:85, v/v), combination of methanol–water–acetic acid (19:81:1.5, v/v), a mixture of aqueous phosphoric acid solution (0.1%) and acetonitrile (90:10 v/v), and so on. In these investigations, a flow rate of 1.0 mL/min or 1.5 mL/min was set up with isocratic or gradient elution and UV detection at 300 nm [18, 19]. Different stationary phases were used, as well. However, there is a constant need to improve analytical methods for quantitative determination in order to obtain a more accurate, precise, sensitive, and selective method for determination of chlorogenic acid in green coffee. Therefore, the objective of the present work was the development and validation of an analytical method for determination of chlorogenic acid in green coffee. The method is required to have excellent sensitivity, i.e., low limit of detection (LOD) and limit of quantification (LOQ), so that low concentrations of chlorogenic acid can be determined.

Experimental

Chemicals and Reagents

The analytical standard of chlorogenic acid (95%) was produced by Sigma Aldrich (Germany). The mobile phase was prepared using acetonitrile, water (HPLC grade), methanol, and phosphoric acid (85.5%), all produced by Sigma Aldrich (Germany). One commercial product containing green coffee purchased from a local pharmacy and 4 samples of green coffee produced by “Rio Coffee” company from Skopje, Macedonia, were used in this investigation.

Instrumentation

Liquid chromatography analysis was performed on an Agilent 1260 Infinity Rapid Resolution Liquid Chromatography (RRLC) system equipped with a vacuum degasser (G1322A), a binary pump (G1312B), an auto sampler (G1329B), a thermostatted column compartment (G1316A), a UV/Vis diode array detector (G1316B), and ChemStation software. For separation and quantification of investigated chlorogenic acid, the following columns, Purospher STAR RP-18e (30 × 4 mm; 3 μm), LiChrospher 60 RP-select B (125 × 4 mm; 5 μm), and Poroshell 120 EC-C18 (50 mm × 3 mm; 2.7 μm), were used. Ultrasonic bath “Elma” (D-7700 SINGEN/Htw., Germany) was applied for dissolution of a stock solution.

Preparation of Standard and Working Solution

Standard solution of chlorogenic acid was prepared by dissolving 0.0173 g of analytical standards in methanol in a 10-mL volumetric flask. The prepared stock solution was degassed using an ultrasonic bath “Elma “for 15 min. In order to test the linearity of the method, 6 working solutions with different concentration of chlorogenic acid were prepared by appropriate dilution of the standard solutions with 80% methanol. Preparation of these solutions was achieved with standard solution volumes of 75 μL, 175 μL, 350 μL, 525 μL, 700 μL, and 875 μL of chlorogenic acid in 10-mL volumetric flasks. All solutions were stored in the dark in a refrigerator at a temperature of 4 °C.

Sample Preparation

Five different samples marked with numbers 1, 2, 3, 4, and 5 were analyzed applying developed method. A mass of 0.25 g from each sample was measured in triplicate into a 50-mL beaker. After that, to the beaker, different solvents were added in order to establish the extraction procedure that gives the best results. Three different extraction procedures for all samples were performed.

First extraction: 0.25 g sample and 25 mL distillated water were mixed into a 50-mL beaker and then were heated and boiled for 5 min with continuous mixing.

Second extraction: 0.25 g sample and 25 mL distillated water were mixed into a 50-mL beaker and then were ultrasonicated for 15 min with an ultrasonic bath.

Third extraction: 0.25 g sample and 25 mL methanol water were mixed into a 50-mL beaker and then were ultrasonicated for 15 min with an ultrasonic bath.

After extraction, 1 mL from each extract was transferred in a 10-mL volumetric flask and filled up to the mark with 80% methanol. Prior to RRLC analysis, these extracts were filtered through 0.45 μm Iso-Disc PTFE syringe filters (Supelco, Sigma Aldrich, Germany). Finally, a volume of 5 μL was injected into the column in triplicate.

RRLC Conditions

Preliminary studies for the development of the RRLC method for determination of chlorogenic acid involved 3 different analytical columns and a mobile phase with different compositions. Columns: Purospher STAR RP-18e (30 × 4 mm; 3 μm), LiChrospher 60 RP-select B (125 × 4 mm; 5 μm), and Poroshell 120 EC-C18 (50 × 3 mm; 2.7 μm) were tested. Mobile phase consisted of acetonitrile–water, methanol–water, methanol–0.5% formic acid in water, and methanol–0.05% formic acid in water with different volume ratios were tested. The chromatographic analysis was performed using isocratic elution with a flow rate of 1 mL/min, and a volume of 5 μL was injected into the chromatographic system, at room temperature. A wavelength of 325 nm was set up for UV detection. The retention time of chlorogenic acid under the abovementioned chromatographic conditions was 0.96 min, which means that the time of the analyses was less than 1 min. Chlorogenic acid in the samples was identified on the basis of the retention time, as well as by comparison between the UV spectrum of chlorogenic acid in the standard solution and the UV spectrum of the detected peak in the samples. Quantification was made with a freshly prepared standard curve of chlorogenic acid.

Results and Discussion

UV Spectrum of Chlorogenic Acid

The UV spectrum of chlorogenic acid recorded in acetonitrile–water with 1% phosphoric acid (10:90, v/v), with a flow rate of 1 mL/min at 25 °C, is presented in Figure 1.

Figure 1.
Figure 1.

UV spectrum of chlorogenic acid in acetonitrile–water with 1% phosphoric acid (10:90, v/v), at a flow rate of 1 mL/min, with UV detection at 325 nm, and at 25 °C

Citation: Acta Chromatographica Acta Chromatographica 32, 1; 10.1556/1326.2019.00547

As it can be seen from Figure 1 in the UV spectrum of chlorogenic acid, there are 2 absorption maxima. First maximum, which is less intensive, appears at the 220-nm wavelength, and the second one is located at the 325-nm wavelength. Hence, the chromatographic process of determination of chlorogenic acid was followed at 325 nm.

Method Development

As it was mentioned in the experimental, 3 different analytical columns and a mobile phase with different compositions were tested. The obtained results showed that the optimal conditions for qualitative and quantitative determination of chlorogenic acid in green coffee samples were achieved using the analytical column Poroshell 120 EC-C18 (50 × 3 mm; 2.7 μm), isocratic elution with a mobile phase composed of acetonitrile–water with 1% phosphoric acid (10:90, v/v), a flow rate of 1 mL/min, UV detection at 325 nm, and a temperature of 25 °C (Figure 2).

Figure 2.
Figure 2.

Chromatogram of analytical standard of chlorogenic acid obtained with a mobile phase consisting of acetonitrile and 1% phosphoric acid dissolved in water (10:90, v/v), at a flow rate of 1 mL/min and a temperature of 25 °С and with UV detection at 325 nm

Citation: Acta Chromatographica Acta Chromatographica 32, 1; 10.1556/1326.2019.00547

From Figure 2, it can be seen that under the defined experimental conditions, the dead time of the column was 0.25 min, while the retention time of investigated chlorogenic acid was 0.96 min. The calculated retention factor value was 2.76, which is the optimal value for this parameter [20]. The columns Purospher STAR RP-18e (30 × 4 mm; 3 μm) and LiChrospher 60 RP-select B (125 × 4 mm; 5 μm) were not efficient enough for separation and quantification of chlorogenic acid in the presence of the other isomers in the coffee samples.

Method Validation

Validation of the method for determination of chlorogenic acid in green coffee was performed testing following parameters: linearity, specificity, selectivity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ). Linearity is actually the ability of a method to obtain test results that are directly proportional to the analyte concentration within a given range. To evaluate linearity, a minimum of 5 concentration levels are required. In our investigation, six working solutions of chlorogenic acid in the investigated concentration region were tested by RRLC with ultraviolet detection (RRLC–UV) in order to set up the linearity of the developed method. A 5-μL volume of each test solution was injected in triplicate. The plot of the peak area/height versus concentration of chlorogenic acid was found to be linear in the concentration region from 12.33 to 143.50 μg/mL (Table 1).

Table 1.

Linearity data for determination of chlorogenic acid

Linearity range (μg/mL) Regression equation R 2
12.33–143.50 peak area y = 4.3215x + 25.763 0.9980
peak height y = 0.7364x + 12.203 0.9981

An acceptance criterion for linearity is that the value of coefficient of determination (R2) is not less than 0.99 [21]. In our work, the calculated values of R2 ≥ 0.998 demonstrated that the developed method for determination of chlorogenic acid was characterized by excellent linearity (Table 1). The specificity and selectivity of the developed method were estimated with the identification of peak of interest and the obtained values for purity index. The identification of analyte was performed by comparison of the retention time of analytical standard with the retention time of chlorogenic acid in the analyzed green coffee samples. Additionally, the identification was confirmed with overlapping the absorption spectrum of pure analytical standard and the absorption spectrum of chlorogenic acid in the analyzed samples. Thereby, the value of a match factor was taken into consideration. The value of this factor was greater than 999, which confirmed that the chromatographic peak originated from the same compound (Figure 3).

Figure 3.
Figure 3.

Overlapped UV spectra of chlorogenic acid in the standard solution and the sample, with the mobile phase acetonitrile–water with 1% phosphoric acid (10:90, v/v), at a flow rate of 1 mL/min, with UV detection at 325 nm, and at 25 °C

Citation: Acta Chromatographica Acta Chromatographica 32, 1; 10.1556/1326.2019.00547

Precision is the measure of the degree of repeatability of an analytical method, and it is expressed as the relative standard deviation (RSD) for a significant number of samples. The RSD for the replicate of injections should not be greater than 1.5% [22]. In our study, the precision of the developed method was expressed as intra-day precision. In order to test precision, 10 successive injections of analytical standard with a mass concentration of 12.33 μg/mL were made.

The calculated RSD values using peak area, retention time and peak height are given in Table 2.

Table 2.

Intraday precision, LOD, and LOQ of the method

RSD retention time (%) RSD peak area (%) RSD peak height (%) LOD (pg) LOQ (pg)
1.10 0.19 1.32 0.29 0.96

These obtained RSD values demonstrated that the developed method for determination of chlorogenic acid is repeatable. Limit of detection (LOD) and limit of quantification (LOQ) values were determined in order to evaluate the sensitivity of the developed method. LOD is the lowest concentration of analyte in a sample that can be detected, while LOQ is defined as the lowest amount of analyte which can be reproducibly quantified under the defined experimental conditions. In order to determine LOD and LOQ, the solution was injected three times, and then the signal-to-noise ratio (S/N) for each injection was determined. LOD was determined as the amount of analyte which produces an S/N ratio of 3:1. LOQ was determined in the same manner but with S/N = 10:1. The values of LOD and LOQ for chlorogenic acid using this method are shown in Table 2.

The accuracy of the method measures the agreement between the accepted reference value and the obtained value using the method of standard addition [23]. Accuracy was measured as the percentage of analyte recovered after spiking the known amount of the analytical standard into a sample of green coffee which already contained a determined amount of chlorogenic acid. The obtained RSD values give an indication of the accuracy of the developed method. The mean recovery of the assay should be within 100 ± 5% at each concentration over the studied range [24]. In order to determine the accuracy, 3 concentration levels were analyzed, i.e., 9 injections into the chromatographic system. A known amount of chlorogenic acid was spiked into sample 1. The average recovery and RSD for each concentration level was calculated, and the obtained results are presented in Table 3.

Table 3.

Recovery data of the developed method, n = 3

Mass of analyte (ng) Pure analyte added (ng) Total analyte found (ng) (±SD) Recovery (%) RSD (%)
Sample 1 109.16 82 200.28 ± 0.76 104.77 0.62
109.16 164 263.04 ± 0.31 97.87 0.13
109.16 246 378.86 ± 0.25 106.67 0.13

As it can be seen from the data listed in Table 3, the calculated recovery values were ranged between 97.87 and 106.67%. These results showed that the developed method had good recovery at the 3 studied concentration levels with RSD values lower than 1%, i.e., it can be successfully employed for quantitative determination of chlorogenic acid in green coffee samples.

Analysis of Chlorogenic Acid in Green Coffee Samples

The applicability of the developed method was tested by the identification and quantitation of the chlorogenic acid in one commercial product containing green coffee and 4 samples of green coffee. Identification of the chlorogenic acid was based on retention time in comparison with the analytical standard, while the quantification was carried out using the external standard method. The concentration of chlorogenic acid was calculated using the peak area and the calibration curves obtained from the used standard solutions. The amount of chlorogenic acid was expressed as ng per 5 μL of the sample. All samples were prepared according to the first extraction procedure explained in Sample Preparation. This way of extraction was chosen because it gave the best results for extraction of chlorogenic acid. In addition, chlorogenic acid was not successfully extracted using the second and third ways of extraction. The obtained average values for the determined amount of chlorogenic acid in the investigated samples are shown in Table 4. The chromatogram of the chlorogenic acid detected in sample 5 is presented in Figure 4.

Table 4.

Mass and mass fraction of chlorogenic acid in the analyzed samples, n = 3

Sample m (ng) ± SD (volume of 5 μL) RSD (%) Mass fraction[%]
1 109.16 ± 0.33 0.28 2.18
2 146.51 ± 0.35 0.24 2.93
3 158.86 ± 0.10 0.06 3.18
4 154.65 ± 0.38 0.24 3.09
5 169.47 ± 1.14 0.67 3.39
Figure 4.
Figure 4.

Chromatogram of sample 5, with the mobile phase acetonitrile–water with 1% phosphoric acid (10:90, v/v), at a flow rate of 1 mL/min, with UV detection at 325 nm, and at 25 °C

Citation: Acta Chromatographica Acta Chromatographica 32, 1; 10.1556/1326.2019.00547

The obtained results showed that the concentration of chlorogenic acid was similar for green coffee samples from 2 to 5, while the concentration of chlorogenic acid was lower for the investigated commercial product containing green coffee. The RSD values were less than 1% for all investigated samples.

Conclusion

In this work, a simple, precise, accurate, and selective RRLC method with UV–DAD detection for determination of chlorogenic acid in green coffee was developed and validated. Separation was achieved on a Poroshell 120 EC-C18 (50 mm × 3 mm; 2.7 μm) column with a mobile phase consisted of water with 1% H3PO4 and acetonitrile (90:10, v/v). The great advantage of this method over those known from the literature is the composition of the mobile phase, i.e., a small amount of acetonitrile was used. Under the used experimental conditions, the retention time of chlorogenic acid was 0.94 min. Hence, the analysis was completed in a shorter time compared to the previously published methods. Furthermore, a simple procedure for extraction of chlorogenic acid from the samples was used. The method was validated for linearity, LOD, LOQ, accuracy, and precision. The obtained results demonstrated that the developed method was characterized with linearity in a wide range, and it was accurate with a recovery between 97.87 and 106.67%. This method was also precise, which was confirmed by the RSD values lower than 1%. Low LOD and LOQ enable the detection and quantification of chlorogenic acid at a low concentration. All mentioned performances made this method suitable for routine analysis of chlorogenic acid in green coffee samples.

References

  • 1.

    Ayelign, A.; Sabally, K. Am. J. Res. Commun., 2013, 1, 78.

  • 2.

    Franca, A. S.; Mendonca, J. C. F.; Oliveira, S. D. Food Sci. Technol., 2005, 38, 709.

  • 3.

    Liu, H.; Shao, J.; Li, Q.; Li, Y.; Yan, H. M.; He, L. J. AOAC Int. 2012, 95, 1138.

  • 4.

    Gebeyehu, B. T.; Bikila, S. L. Am. J. Appl. Chem., 2015, 3, 69.

  • 5.

    Fuentes, E.; Palomo, I. Vascul. Pharmacol., 2014, 63, 155.

  • 6.

    Belay, A.; Gholap, A. V. Afr. J. Pure and Appl. Chem., 2009, 3, 234.

  • 7.

    Farah, A.; Paulis, T. D.; Moreira, D. P.; Trugo, L. C.; Martin, P. R. J. Agric. Food Chem., 2006, 54, 374.

  • 8.

    Mills, C.; Oruna-Concha, M. J.; Mottram, D. S.; Spencer, J. P. E. Food Chem., 2013, 141, 3335.

  • 9.

    Hecimovic, I.; Belscak-Cvitanovic, A.; Horzic, D.; Komes, D. Food Chem., 2011, 129, 991.

  • 10.

    Lough, W. J.; Wainer, I. W. High Performance Liquid Chromatography, Fundamental Principles and Practice Blackie Academic & Professional UK. Chapman & Hall, Glasgow, 1996, p. 1167.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 11.

    Mullen, W.; Freeke, J.; Barattini, V. Fast analysis of Coffee Bean Extracts Using a Solid Core HPLC Column, University of Glasgow, UK, 2012, p. 1.

    • Search Google Scholar
    • Export Citation
  • 12

    Jeszka-Skowron, M.; Zgoła-Grześkowiak, A.; Grześkowiak, T. Eur. Food Res. Technol. 2015, 240, 19.

  • 13.

    Craig, A. P.; Fields, C.; Liang, N.; Kitts, D.; Erickson, A. Talanta, 2016, 154, 481485.

  • 14.

    Rostagno, M.; Manchón, N.; D’Arrigo, M.; Guillamón, E.; Villares, A.; García-Lafuente, A. Anal. Chim. Acta., 2011, 685, 204.

  • 15.

    Naczk, M.; Shahidi, F. J. Chromatogr. A, 2004, 1054, 95.

  • 16.

    Pyrzynska, K.; Sentkowska, A. Crit. Rev. Anal. Chem., 2015, 45, 41.

  • 17.

    Robards, K. J. Chromatogr. A., 2003, 1000, 657.

  • 18.

    Li, X.P.; Yu, J.; Luo, J.Y.; Li, H.S.; Han, F.J.; Chen, X.G.; Hu, Z.D. Chem. Pharm. Bull., 2004, 52, 1251.

  • 19.

    Pellati, F.; Benvenuti, S.; Melegari, M.; Lassegni, T. Phytochem. Anal., 2005, 16, 77.

  • 20.

    Meyer, V. R. Practical High-Performance Liquid Chromatography 2nd Ed., John Wiley & Sons. England, Chichester, 1994, p. 1267.

  • 21.

    Al-Rimawi, F.; Odeh, I. J. AOAC Int., 2015, 98, 1335.

  • 22.

    Huber, L. Validation and Qualification in the Analytical Laboratories Interpharm Press, Buffalo Grove, IL, 1998, p. 107.

  • 23.

    Skoog, D.A.; West, D.M.; Holler, F. J. Analytical chemistry 6th Ed., Saunders College Publishing, 1994, p. 490530.

  • 24.

    Wegscheider, W. Accreditation and Quality Assurance in Analytical Chemistry, ed. Guenzler, H., Springer Verlag, Berlin, Germany, 1996, p. 1.

    • Search Google Scholar
    • Export Citation
  • 1.

    Ayelign, A.; Sabally, K. Am. J. Res. Commun., 2013, 1, 78.

  • 2.

    Franca, A. S.; Mendonca, J. C. F.; Oliveira, S. D. Food Sci. Technol., 2005, 38, 709.

  • 3.

    Liu, H.; Shao, J.; Li, Q.; Li, Y.; Yan, H. M.; He, L. J. AOAC Int. 2012, 95, 1138.

  • 4.

    Gebeyehu, B. T.; Bikila, S. L. Am. J. Appl. Chem., 2015, 3, 69.

  • 5.

    Fuentes, E.; Palomo, I. Vascul. Pharmacol., 2014, 63, 155.

  • 6.

    Belay, A.; Gholap, A. V. Afr. J. Pure and Appl. Chem., 2009, 3, 234.

  • 7.

    Farah, A.; Paulis, T. D.; Moreira, D. P.; Trugo, L. C.; Martin, P. R. J. Agric. Food Chem., 2006, 54, 374.

  • 8.

    Mills, C.; Oruna-Concha, M. J.; Mottram, D. S.; Spencer, J. P. E. Food Chem., 2013, 141, 3335.

  • 9.

    Hecimovic, I.; Belscak-Cvitanovic, A.; Horzic, D.; Komes, D. Food Chem., 2011, 129, 991.

  • 10.

    Lough, W. J.; Wainer, I. W. High Performance Liquid Chromatography, Fundamental Principles and Practice Blackie Academic & Professional UK. Chapman & Hall, Glasgow, 1996, p. 1167.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 11.

    Mullen, W.; Freeke, J.; Barattini, V. Fast analysis of Coffee Bean Extracts Using a Solid Core HPLC Column, University of Glasgow, UK, 2012, p. 1.

    • Search Google Scholar
    • Export Citation
  • 12

    Jeszka-Skowron, M.; Zgoła-Grześkowiak, A.; Grześkowiak, T. Eur. Food Res. Technol. 2015, 240, 19.

  • 13.

    Craig, A. P.; Fields, C.; Liang, N.; Kitts, D.; Erickson, A. Talanta, 2016, 154, 481485.

  • 14.

    Rostagno, M.; Manchón, N.; D’Arrigo, M.; Guillamón, E.; Villares, A.; García-Lafuente, A. Anal. Chim. Acta., 2011, 685, 204.

  • 15.

    Naczk, M.; Shahidi, F. J. Chromatogr. A, 2004, 1054, 95.

  • 16.

    Pyrzynska, K.; Sentkowska, A. Crit. Rev. Anal. Chem., 2015, 45, 41.

  • 17.

    Robards, K. J. Chromatogr. A., 2003, 1000, 657.

  • 18.

    Li, X.P.; Yu, J.; Luo, J.Y.; Li, H.S.; Han, F.J.; Chen, X.G.; Hu, Z.D. Chem. Pharm. Bull., 2004, 52, 1251.

  • 19.

    Pellati, F.; Benvenuti, S.; Melegari, M.; Lassegni, T. Phytochem. Anal., 2005, 16, 77.

  • 20.

    Meyer, V. R. Practical High-Performance Liquid Chromatography 2nd Ed., John Wiley & Sons. England, Chichester, 1994, p. 1267.

  • 21.

    Al-Rimawi, F.; Odeh, I. J. AOAC Int., 2015, 98, 1335.

  • 22.

    Huber, L. Validation and Qualification in the Analytical Laboratories Interpharm Press, Buffalo Grove, IL, 1998, p. 107.

  • 23.

    Skoog, D.A.; West, D.M.; Holler, F. J. Analytical chemistry 6th Ed., Saunders College Publishing, 1994, p. 490530.

  • 24.

    Wegscheider, W. Accreditation and Quality Assurance in Analytical Chemistry, ed. Guenzler, H., Springer Verlag, Berlin, Germany, 1996, p. 1.

    • Search Google Scholar
    • Export Citation
  • Collapse
  • Expand

Senior editors

Editor(s)-in-Chief: Sajewicz, Mieczyslaw, University of Silesia, Katowice, Poland

Editors(s)

  • Danica Agbaba, University of Belgrade, Belgrade, Serbia (1953-2024)
  • Łukasz Komsta, Medical University of Lublin, Lublin, Poland
  • Ivana Stanimirova-Daszykowska, University of Silesia, Katowice, Poland
  • Monika Waksmundzka-Hajnos, Medical University of Lublin, Lublin, Poland

Editorial Board

  • Ravi Bhushan, The Indian Institute of Technology, Roorkee, India
  • Jacek Bojarski, Jagiellonian University, Kraków, Poland
  • Bezhan Chankvetadze, State University of Tbilisi, Tbilisi, Georgia
  • Michał Daszykowski, University of Silesia, Katowice, Poland
  • Tadeusz H. Dzido, Medical University of Lublin, Lublin, Poland
  • Attila Felinger, University of Pécs, Pécs, Hungary
  • Kazimierz Glowniak, Medical University of Lublin, Lublin, Poland
  • Bronisław Glód, Siedlce University of Natural Sciences and Humanities, Siedlce, Poland
  • Anna Gumieniczek, Medical University of Lublin, Lublin, Poland
  • Urszula Hubicka, Jagiellonian University, Kraków, Poland
  • Krzysztof Kaczmarski, Rzeszow University of Technology, Rzeszów, Poland
  • Huba Kalász, Semmelweis University, Budapest, Hungary
  • Katarina Karljiković Rajić, University of Belgrade, Belgrade, Serbia
  • Imre Klebovich, Semmelweis University, Budapest, Hungary
  • Angelika Koch, Private Pharmacy, Hamburg, Germany
  • Piotr Kus, Univerity of Silesia, Katowice, Poland
  • Debby Mangelings, Free University of Brussels, Brussels, Belgium
  • Emil Mincsovics, Corvinus University of Budapest, Budapest, Hungary
  • Ágnes M. Móricz, Centre for Agricultural Research, Budapest, Hungary
  • Gertrud Morlock, Giessen University, Giessen, Germany
  • Anna Petruczynik, Medical University of Lublin, Lublin, Poland
  • Robert Skibiński, Medical University of Lublin, Lublin, Poland
  • Bernd Spangenberg, Offenburg University of Applied Sciences, Germany
  • Tomasz Tuzimski, Medical University of Lublin, Lublin, Poland
  • Adam Voelkel, Poznań University of Technology, Poznań, Poland
  • Beata Walczak, University of Silesia, Katowice, Poland
  • Wiesław Wasiak, Adam Mickiewicz University, Poznań, Poland
  • Igor G. Zenkevich, St. Petersburg State University, St. Petersburg, Russian Federation

 

SAJEWICZ, MIECZYSLAW
E-mail:mieczyslaw.sajewicz@us.edu.pl

Indexing and Abstracting Services:

  • Science Citation Index
  • Sci Search
  • Research Alert
  • Chemistry Citation Index and Current Content/Physical
  • Chemical and Earth Sciences
  • SCOPUS
  • GoogleScholar
  • Index Copernicus
  • CABI
  • CABELLS Journalytics

2023  
Web of Science  
Journal Impact Factor 1.7
Rank by Impact Factor Q3 (Chemistry, Analytical)
Journal Citation Indicator 0.43
Scopus  
CiteScore 4.0
CiteScore rank Q2 (General Chemistry)
SNIP 0.706
Scimago  
SJR index 0.344
SJR Q rank Q3

Acta Chromatographica
Publication Model Online only
Gold Open Access
Submission Fee none
Article Processing Charge 400 EUR/article
Effective from  1st Feb 2025:
700 EUR/article
Regional discounts on country of the funding agency World Bank Lower-middle-income economies: 50%
World Bank Low-income economies: 100%
Further Discounts Editorial Board / Advisory Board members: 50%
Corresponding authors, affiliated to an EISZ member institution subscribing to the journal package of Akadémiai Kiadó: 100%
Subscription Information Gold Open Access
Purchase per Title  

Acta Chromatographica
Language English
Size A4
Year of
Foundation
1988
Volumes
per Year
1
Issues
per Year
4
Founder Institute of Chemistry, University of Silesia
Founder's
Address
PL-40-007 Katowice, Poland, Bankowa 12
Publisher Akadémiai Kiadó
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 2083-5736 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Aug 2024 0 58 21
Sep 2024 0 76 39
Oct 2024 0 249 18
Nov 2024 0 195 11
Dec 2024 0 220 21
Jan 2025 0 83 14
Feb 2025 0 0 0