This paper presents a new, simple, precise, and accurate rapid resolution liquid chromatography (RRLC) method for determination of an active ingredient malathion in the pesticide formulation. The analysis was performed on a Poroshell EC 120-C18 (50 mm × 3 mm, 2.7 μm) analytical column using isocratic elution with a mobile phase consisted of acetonitrile–water (50:50, v/v), a flow rate of 1 mL/min, a constant column temperature at 25 °C, and ultraviolet-diode array detection (UV-DAD) at 220 nm. The specificity, selectivity, linearity, precision, and accuracy were tested for the method validation according to the Collaborative International Pesticides Analytical Council (CIPAC) and Directorate General Health and Consumer Protection (SANCO) guidelines and all tested parameters were found within acceptance criteria. The obtained results indicated that the proposed method can be used for routine analysis of the active ingredient malathion in the pesticide formulation “Etiol tecni” following the CIPAC and SANCO rules. The run time of analysis under the stipulated chromatographic conditions was about 2.5 min, meaning that the proposed method requires a small volume (< 1.5 mL) of the organic solvent (acetonitrile) making it cost-effective.

Abstract

This paper presents a new, simple, precise, and accurate rapid resolution liquid chromatography (RRLC) method for determination of an active ingredient malathion in the pesticide formulation. The analysis was performed on a Poroshell EC 120-C18 (50 mm × 3 mm, 2.7 μm) analytical column using isocratic elution with a mobile phase consisted of acetonitrile–water (50:50, v/v), a flow rate of 1 mL/min, a constant column temperature at 25 °C, and ultraviolet-diode array detection (UV-DAD) at 220 nm. The specificity, selectivity, linearity, precision, and accuracy were tested for the method validation according to the Collaborative International Pesticides Analytical Council (CIPAC) and Directorate General Health and Consumer Protection (SANCO) guidelines and all tested parameters were found within acceptance criteria. The obtained results indicated that the proposed method can be used for routine analysis of the active ingredient malathion in the pesticide formulation “Etiol tecni” following the CIPAC and SANCO rules. The run time of analysis under the stipulated chromatographic conditions was about 2.5 min, meaning that the proposed method requires a small volume (< 1.5 mL) of the organic solvent (acetonitrile) making it cost-effective.

Introduction

Since ancient times, the harmful effects of insects on food, domestic animals, and humans have been observed, and insecticides have been used to destroy them. Recent research has focused on the synthesis of new organophosphorus compounds that are less toxic to humans and more effective at destroying insects and other harmful biological agents. Organophosphorus insecticides are widely used because of their relatively rapid decomposition and low accumulation in living organisms. One of the most used organophosphorus insecticides in our country and in the world is malathion, which has been approved for use according to the European Commission Regulation (EC) No 1107/2009 [1] and EPA [2], etc. Malathion (Figure 1a) is a generally accepted name according to the International Organization for Standardization (ISO), while according to IUPAC (International Union of Pure and Applied Chemistry) the name of this active component is diethyl(dimethoxythiophosphorylthio)succinate; S-1,2-bis(ethoxycarbonyl)ethyl-O,O-dimethyl phosphorodithioate [3].

Figure 1.
Figure 1.

Chemical structure of malathion (a) and its UV spectrum in acetonitrile–water (50:50, v/v) (b)

Citation: Acta Chromatographica Acta Chromatographica 32, 4; 10.1556/1326.2019.00713

Malathion is a non-systematic insecticide and acaricide of low mammalian toxicity, with contact, stomach, and respiratory action. In addition, it is a cholinesterase inhibitor [3]. Malathion is present as an active substance in many pesticide products, including “Etiol tecni”, which is in the form of emulsifiable concentrate (EC).

New pesticide formulations are constantly being developed, which represent ever-better solutions to suppress harmful biological agents, thereby increasing the need for constant quality control of the pesticides placed on the market. This is especially important because the quality of plant protection products affects the crop safety, as well as the environment and the human health. The improvement of existing and, in particular, the development of new analytical methods for the determination of active substances in plant protection products are necessary to control the quality of pesticide formulations.

The literature search shows that various analytical methods for determining malathion in different matrices are known. Thus, for example, the determination of malathion and its residues can be performed using gas–liquid chromatography (GLC) [3]. More than 30 years ago, malathion in pesticide formulations was determined by volumetric methods such as argentometric [4], iodometric [5, 6], or complexometric following alkaline hydrolysis [7, 8]. Also used are spectrophotometric methods [9, 10], atomic absorption spectroscopy (AAS) [11], gas chromatography (GC) [12], or by environmental friendly methods such as Fourier transform infrared spectroscopy (FTIR) [13] and Fourier transform Raman spectroscopy (FTRS) [14]. Collaborative International Pesticides Analytical Council (CIPAC) has published reference methods using gas–liquid chromatography [15] and gas chromatography [16] for the determination of active substance malathion in technical material (TC), dustable powders (DP), wettable powders (WP), emulsifiable concentrates (EC), oil miscible liquid (OL) and emulsion, and oil in water (EW).

The literature search shows that only a small number of publications are related to the analysis of active substances in the pesticide formulation and their quality control. However, to date, no analytical method for the determination of malathion in pesticide formulations by liquid chromatography (LC) has been published in the literature. Hence, the aim of this study was to develop a new, simple, fast, and convenient method for the determination of malathion in pesticide formulation in the form of an emulsifiable concentrate using rapid resolution liquid chromatography (RRLC) method with ultraviolet-diode array detection (UV-DAD). The research within this paper represents contribution in the field of new analytical methods for determination of active substances in the plant protection products. The development and publication of new analytical methods for analysis of pesticides enable control laboratories to save time and money in developing of their own methods and to carry out more efficient quality control of these products.

Experimental

Equipment and Materials

The chromatographic analysis was performed on an Agilent 1260 Infinity Rapid Resolution Liquid Chromatography (RRLC) system equipped with the following: a vacuum degasser (G1322A), a binary pump (G1312B), an autosampler (G1329B), a column compartment (G1316A), a UV–vis diode array detector (G1316B), and ChemStation software. The experiments were carried out using a Poroshell EC 120-C18 (50 mm × 3 mm, 2.7 μm) analytical column produced by Agilent Technologies (USA).

For the better dissolving of the stock solution and sample solution, an ultrasonic bath “Elma” was used.

The Pestanal analytical standard of malathion (97.2% purity), as well as HPLC-grade acetonitrile and water, were purchased by Sigma-Aldrich (Germany).

The pesticide formulation “Etiol tecni”, which was in the form of an emulsifiable concentrate (EC) was produced by “Galenika-fitofarmacija” (Belgrade, Serbia). The declared value for the content of malathion was 600 g/L ± 25 g/L, and for density, it was 1.075 g/mL.

Preparation of Standard Solutions

Stock solution of malathion was prepared by dissolving 0.0330 g of the pure analytical standard with acetonitrile in a 25-mL volumetric flask. To perform better dissolution of the active component, the prepared stock solution was ultrasonicated for 15 min in an ultrasonic bath. The stock solution was stored in a refrigerator at 4 °C. Under these conditions, the stability of the active component was greater than 1 month. During the tests, working standard solutions were prepared by diluting the stock solution with a mixture of equivalent volumes of acetonitrile and water in 10-mL flasks.

To test the linearity of the method, a series of 5 working standard solutions with a concentration of 46.75, 93.50, 187.00, 280.50, and 374.00 μg/mL were prepared. Each of these working solutions was injected three times with a volume of 5 μL.

Preparation of Sample Solution

For the quantitative determination of the active ingredient malathion, 0.0333 g of the pesticide formulation “Etiol tecni” was weighed in a 10-mL volumetric flask and dissolved in equal volumes of acetonitrile and water. The solution was degassed for 15 min in an ultrasonic bath, and then a portion of 0.5 mL volume was transferred to a 10-mL volumetric flask and supplemented with a mixture of equal volumes of acetonitrile and water. Four injections were performed with a volume of 5 μL of this solution. Filtering the sample solution was not required because of its complete solubility in the solvents used.

To determine the recovery of the method in 3 flasks of 10 mL, 0.5 mL of the prepared sample solution was taken. To each solution was added a known quantity of analytical standard of malathion: 23.37, 46.75, and 93.49 μg/mL. The flasks were then filled up to the mark with a mixture of acetonitrile and water at a volume ratio of 50:50. Four injections were performed with 5 μL of each of these solutions.

Results and Discussion

Chromatography Study

The choice of wavelength on which the chromatographic analyses was performed was based on the UV spectrum of malathion recorded in a solution of acetonitrile and water (50:50, v/v). The UV spectrum of malathion is presented in the Figure 1b. As can be seen from the UV spectrum of malathion, the maximum band cannot be noticed, but it is observed that the absorption increases with decreasing wavelength. Hence, the chromatographic analysis for the determination of malathion in the pesticide formulation was carried out at 220 nm.

Investigations were performed on Poroshell 120 EC-C18 (50 mm × 3 mm, 2.7 μm) analytical column. Poroshell 120 was selected as the stationary phase, because it provides exceptional efficiency, i.e., increased speed and, at the same time, increased resolution of the chromatographic process within the existing pressure range of current instruments and higher resolution and speed of new LC and LC–MS systems enable work at higher pressures [17]. These columns are mechanically stable and can be used up to a pressure of 600 bar (9000 psi) and a temperature of up to 60 °C. Poroshell 120 EC-C18 is intended for reversed-phase chromatography and can be used for base, neutral, or acid samples at a pH of 2 to 9 [18, 19].

In order to develop a simple RRLC method for the determination of the active component of malathion in a pesticide formulation, the chromatographic process was run using an isocratic elution, i.e., by the use of constant composition of the mobile phase. Acetonitrile and water in various volume ratios were used for the preparation of mobile phase. Because of higher elution strength, аcetonitrile was chosen as an organic solvent.

To obtain the optimum conditions for the chromatographic determination of malathion, a series of experiments were performed by varying the volume ratio of acetonitrile and water in the mobile phase. The best chromatographic conditions were achieved using isocratic elution with a mobile phase consisted of acetonitrile–water (50:50, v/v) (Figure 2), a flow rate of 1 mL/min, a constant column temperature at 25 °C, and UV detection at 220 nm. Under these experimental conditions, a smooth baseline was obtained, and the chromatographic peak of malathion was high, narrow, and symmetrical, with a satisfactory value for the purity index (>999) (Figure 2a). The column dead time (t0) value was 0.19 min, and the retention time (tR) was 1.46 min, so the calculated value for retention factor (k′) was 6.68. This value for the retention factor is less than 10, which is the maximum acceptable value according to some authors for this parameter [20]. Under these stipulated conditions, a short retention time for malathion was obtained, which means a rapid chromatographic process for its quantification.

Figure 2.
Figure 2.

Chromatograms obtained from analytical standard of malathion (a) and pesticide formulation “Etiol tecni” (b) on the Poroshell EC 120-C18 column (50 mm × 3 mm, 2.7 μm) at 220 nm using the proposed method

Citation: Acta Chromatographica Acta Chromatographica 32, 4; 10.1556/1326.2019.00713

The chromatogram of the pesticide formulation obtained using the proposed method is shown in Figure 2b. As can be seen from Figure 2b, on the chromatogram of the pesticide formulation, in addition to the malathion peak (1), two more peaks of the unknown components were observed (X1 and X2) that eluted slower than malathion, with a retention time of 1.61 min and 1.77 min. Their chromatographic peaks were almost completely separated to the baseline, and from the peak of interest, which was also confirmed by the calculated resolution values (RS = 2.56) and the separation factor (α = 1.10) of the malathion peak and its neighboring peak (X1).

Method Validation

Specificity, selectivity, linearity, precision expressed as intra-day and inter-day repeatability of retention time, peak area and peak height, and accuracy were examined to assess the validity of the developed method in accordance with the CIPAC and SANCO rules [21, 22].

Specificity and Selectivity

To confirm the specificity and selectivity of the developed method, UV-diode array detection was used to check the peak purity and analyte peak identity. The purity index of malathion was greater than 999 (the maximum value for the peak purity index (PPI) should be 1000), which means that the chromatographic peak was not affected by any other compound. In addition, identification of the analyte was done using the value for the retention time and match factor obtained by overlaid spectra of a pure analytical standard and absorption spectra of malathion in the pesticide formulation sample. Figure 3 shows the obtained overlaid spectra of pure analytical standard and absorption spectra of malathion in the pesticide formulation sample. The obtained value for match factors (999.915) confirmed the identity of the malathion.

Figure 3.
Figure 3.

The overlaid UV spectra obtained by comparing the absorption spectra of a pure analytical standard of malathion and absorption spectra of the same analyte in the pesticide formulation

Citation: Acta Chromatographica Acta Chromatographica 32, 4; 10.1556/1326.2019.00713

Linearity

The linearity of the method was tested by constructing calibration curves that give the dependence of the peak area and the peak height on the injected amount of the analyte. For this purpose, a series of 5 working solutions of different concentration in the concentration range shown in Table 1 was prepared. As can be seen from this table, the values of the multiple correlation coefficients were R2 ≥ 0.9990. Therefore, it can be concluded that the proposed method was characterized by excellent linearity in the investigated concentration range. The obtained results for multiple correlation coefficients (R2) indicated preferably the use of peak area as a variable.

Table 1.

Statistical data for linearity

Linearity range (μg/mL)Regression equationR2
46.75–374.00ya = 508.43x + 62.5280.9991
yb = 122.66x + 33.6970.9990

Area.

Height.

Precision

Precision was expressed as repeatability of obtained results, which was evaluated for retention time, peak area, and peak height of the malathion from 8 successive injections of analytical standard with concentration 187.00 μg/mL, within 3 days (Table 2). The proposed method shows high precision in terms of retention time (RSD = 0.88–0.37%), peak area (RSD = 0.20–0.87%), and peak height (RSD = 0,23–1.44%). The RSD values for the retention time, peak area, and peak height of malathion were calculated based on modified Horwitz equation, and the obtained results were within acceptable limits for RSD, which should not exceed 1.46% [21,22].

Table 2.

Statistical data for repeatability

Intra-day repeatability (n = 8)Inter-day repeatability (n = 3)
I dayII dayIII dayx¯± SDRSD (%)
x¯± SDRSD (%)x¯± SDRSD (%)x¯± SDRSD (%)
Retention time (min)1.47 ± 0.0130.881.46 ± 0.0201.371.46 ± 0.0171.171.46 ± 0.0171.19
Peak area509.15 ± 1.050.20501.01 ± 3.870.77507.91 ± 1.890.37506.02 ± 4.400.87
Peak height153.97 ± 0.360.23155.06 ± 1.340.87158.74 ± 0.790.49155.92 ± 2.251.44

Accuracy

The accuracy of the method was confirmed by standard additions [21, 22]. The accuracy of the method was expressed as the deviation between the calculated mean value obtained by examination and the true value of the spiked amounts of the analyte into a sample matrix that already contains some quantity of the analyte (Table 3). The calculated values for the recovery (Table 3) were within the acceptable values according to the CIPAC and SANCO criteria [21, 22] and ranged from 98.24 to 102.00%. According to these criteria, the values for the recovery should range from 98% to 102%. Consequently, it was concluded that the proposed method is accurate enough for the determination of active ingredient malathion in the pesticide formulation “Etiol tecni”.

Table 3.

Results from recovery experiments (n = 4)

Mass of analyte (μg)Pure analyte added (μg)Total analyte found (μg) (±SD)Recovery (%)RSD (%)
0.460.120.57 ± 0.000898.240.15
0.460.230.71 ± 0.0004101.280.06
0.460.470.95 ± 0.0012102.000.13

The experimentally obtained value for the density of the pesticide formulation was 1.069 g/mL. The obtained mean concentration of active ingredient malathion in the pesticide formulation “Etiol tecni” was 597.13 g/L (n = 4, RSD = 0.13%), which corresponded to the value declared by the manufacturer.

Conclusions

The research within this study represents contribution in the field of developing of new analytical methods for determination of active substances in the plant protection products. To date, no analytical method for the determination of malathion in pesticide formulations by liquid chromatography (LC) has been published in the literature. A new, simple, and fast rapid resolution liquid chromatography method (RRLC) for determination of active ingredient malathion in the pesticide formulation “Etiol tecni”, which is in the form of an emulsifiable concentrate (EC), has been developed and validated. Successful separation and quantification was achieved using a Poroshell EC 120-C18 (50 mm × 3 mm, 2.7 μm) analytical column and isocratic elution with a mobile phase consisted of acetonitrile–water (50:50, v/v), a flow rate of 1 mL/min, a constant column temperature at 25 °C, and UV detection at 220 nm. The results from the method validation revealed that the proposed method has a satisfactory linearity (R2 ≥ 0.9990) and excellent precision of retention time, peak area, and height. The obtained values for recoveries ranged from 98.24–102.00%, with RSD of 0.06–0.15%, revealed that the proposed method is convenient for routine determination of malathion in the emulsifiable concentrate pesticide formulation, according to the CIPAC and SANCO rules. The run time of analysis under the stipulated chromatographic conditions was about 2.5 min. The short run time means that the proposed method requires a small volume (<1.5 mL) of the organic solvent (acetonitrile), which makes it cost-effective.

References

  • 1.

    Regulation (EC) No 1107/2009 of the European Parliament and of the Council of 21 October 2009, 2009.

  • 2.

    EPA , Reregistration Eligibility Decision for malathion, 2009.

  • 3.

    Tomlin C. The Pesticide Manual Incorporating the Agrochemicals Handbook, 11th Ed., Crop Protection Publications, 1997, pp. 630631.

  • 4.

    Miles, J. W.; Goette, M. B.; Guerrant, G. O.; Churchill, F. C. JAOAC, 1972, 55, 1133.

  • 5.

    Orth, R. A.; Minett, W. Pestic. Sci., 1975, 6, 217.

  • 6.

    Hill, A. C.; Akhtar, M.; Mumtaz, M.; Osmani, J. A. Analyst, 1967, 92, 496.

  • 7.

    Prasada Rao, P. V. V.; Seshaiah, K.; Naidu, P. R. J. Agric. Food Chem., 1983, 31, 1370.

  • 8.

    Sharma, S. R.; Rathore, H. S.; Ali, I.; Ahmed, S. R. Anal. Lett., 1985, 18, 1181.

  • 9.

    Gouda, A. A.; Amin, A. S.; Sheikh, R. E.; Akl, M. A. Chem. Ind. Chem. Eng. Q., 2010, 16, 11.

  • 10.

    Reddy, K. M.; Suvardhan, K.; Kumar, K. S.; Rekha, D.; Chiranjeevi, P. E-J. Chem., 2005, 2, 187. (http://www.e-journals.net).

  • 11.

    Blas, O. J.; Paz, J. L.; Mendez, J. H. Talanta, 1991, 38, 857.

  • 12.

    Kumari, L. A.; Huat, T. G.; Kin, C. M. Malays. J. Sci., 2006, 25, 131, (URL: http://www.ejum.fsktm.um.edu.my).

  • 13.

    Quintás, G.; Noé, A. M.; Armenta, S.; Garrigues, S.; Guardia, M. Anal. Chim. Acta, 2004, 502, 213.

  • 14.

    Quintás, G.; Garrigues, S.; Guardia, M. Talanta, 2004, 63, 345.

  • 15.

    CIPAC Method Handbook B (Malathion), 12/TC/M.2, 1983, pp. 18491859.

  • 16.

    CIPAC Method Handbook K (Malathion), 12/TC/(M3)/2.1, 2003, pp. 8994.

  • 17.

    Rugged fast LC performance фor HPLC/UHPLC, Agilent Technologies, Inc., 2012.

  • 18.

    Agilent Poroshell 120 EC-C18 Threaded Column, Agilent Technologies, Inc., 2009.

  • 19.

    Agilent Poroshell 120 Columns for HPLC and UHPLC, Perform Rugged, Fast LC with confidence, Agilent Technologies, Inc., 2012.

  • 20.

    Dong M. W. Modern HPLC for Practicing Scientists, John Wiley & Sons, Inc., Hoboken, New Jersey, 2006, pp. 1746.

  • 21.

    CIPAC Document 3807 , Guidelines on method validation to be performed in support of analytical methods for agrochemical formulations, 2003. (http://www.cipac.org).

    • Search Google Scholar
    • Export Citation
  • 22.

    EUROPEAN COMMISSION , Directorate General Health and Consumer Protection, SANCO/3030/99 rev.5, Technical Active Substance and Plant protection products: Guidance for generating and reporting methods of analysis in support of pre- and post-registration data requirements for Annex (Section 4) of Regulation (EU) No 283/2013 and Annex (Section 5) of Regulation (EU) No 284/2013, 2019.

    • Search Google Scholar
    • Export Citation
  • 1.

    Regulation (EC) No 1107/2009 of the European Parliament and of the Council of 21 October 2009, 2009.

  • 2.

    EPA , Reregistration Eligibility Decision for malathion, 2009.

  • 3.

    Tomlin C. The Pesticide Manual Incorporating the Agrochemicals Handbook, 11th Ed., Crop Protection Publications, 1997, pp. 630631.

  • 4.

    Miles, J. W.; Goette, M. B.; Guerrant, G. O.; Churchill, F. C. JAOAC, 1972, 55, 1133.

  • 5.

    Orth, R. A.; Minett, W. Pestic. Sci., 1975, 6, 217.

  • 6.

    Hill, A. C.; Akhtar, M.; Mumtaz, M.; Osmani, J. A. Analyst, 1967, 92, 496.

  • 7.

    Prasada Rao, P. V. V.; Seshaiah, K.; Naidu, P. R. J. Agric. Food Chem., 1983, 31, 1370.

  • 8.

    Sharma, S. R.; Rathore, H. S.; Ali, I.; Ahmed, S. R. Anal. Lett., 1985, 18, 1181.

  • 9.

    Gouda, A. A.; Amin, A. S.; Sheikh, R. E.; Akl, M. A. Chem. Ind. Chem. Eng. Q., 2010, 16, 11.

  • 10.

    Reddy, K. M.; Suvardhan, K.; Kumar, K. S.; Rekha, D.; Chiranjeevi, P. E-J. Chem., 2005, 2, 187. (http://www.e-journals.net).

  • 11.

    Blas, O. J.; Paz, J. L.; Mendez, J. H. Talanta, 1991, 38, 857.

  • 12.

    Kumari, L. A.; Huat, T. G.; Kin, C. M. Malays. J. Sci., 2006, 25, 131, (URL: http://www.ejum.fsktm.um.edu.my).

  • 13.

    Quintás, G.; Noé, A. M.; Armenta, S.; Garrigues, S.; Guardia, M. Anal. Chim. Acta, 2004, 502, 213.

  • 14.

    Quintás, G.; Garrigues, S.; Guardia, M. Talanta, 2004, 63, 345.

  • 15.

    CIPAC Method Handbook B (Malathion), 12/TC/M.2, 1983, pp. 18491859.

  • 16.

    CIPAC Method Handbook K (Malathion), 12/TC/(M3)/2.1, 2003, pp. 8994.

  • 17.

    Rugged fast LC performance фor HPLC/UHPLC, Agilent Technologies, Inc., 2012.

  • 18.

    Agilent Poroshell 120 EC-C18 Threaded Column, Agilent Technologies, Inc., 2009.

  • 19.

    Agilent Poroshell 120 Columns for HPLC and UHPLC, Perform Rugged, Fast LC with confidence, Agilent Technologies, Inc., 2012.

  • 20.

    Dong M. W. Modern HPLC for Practicing Scientists, John Wiley & Sons, Inc., Hoboken, New Jersey, 2006, pp. 1746.

  • 21.

    CIPAC Document 3807 , Guidelines on method validation to be performed in support of analytical methods for agrochemical formulations, 2003. (http://www.cipac.org).

    • Search Google Scholar
    • Export Citation
  • 22.

    EUROPEAN COMMISSION , Directorate General Health and Consumer Protection, SANCO/3030/99 rev.5, Technical Active Substance and Plant protection products: Guidance for generating and reporting methods of analysis in support of pre- and post-registration data requirements for Annex (Section 4) of Regulation (EU) No 283/2013 and Annex (Section 5) of Regulation (EU) No 284/2013, 2019.

    • Search Google Scholar
    • Export Citation
The author instruction is available in PDF.
Please, download the file from HERE.
 
The Open Access statement together with the description of the Copyright and License Policy are available in PDF.
Please, download the file from HERE.
 

 

Senior editors

Editor(s)-in-Chief: Kowalska, Teresa

Editor(s)-in-Chief: Sajewicz, Mieczyslaw

Editors(s) Danica Agbaba (University of Belgrade, Belgrade, Serbia);
Ivana Stanimirova-Daszykowska (University of Silesia, Katowice, Poland),
Monika Waksmundzka-Hajnos (Medical University of Lublin, Lublin, Poland)

Editorial Board

R. Bhushan (The Indian Institute of Technology, Roorkee, India)
J. Bojarski (Jagiellonian University, Kraków, Poland)
B. Chankvetadze (State University of Tbilisi, Tbilisi, Georgia)
M. Daszykowski (University of Silesia, Katowice, Poland)
T.H. Dzido (Medical University of Lublin, Lublin, Poland)
A. Felinger (University of Pécs, Pécs, Hungary)
K. Glowniak (Medical University of Lublin, Lublin, Poland)
B. Glód (Siedlce University of Natural Sciences and Humanities, Siedlce, Poland)
K. Kaczmarski (Rzeszow University of Technology, Rzeszów, Poland)
H. Kalász (Semmelweis University, Budapest, Hungary)
I. Klebovich (Semmelweis University, Budapest, Hungary)
A. Koch (Private Pharmacy, Hamburg, Germany)
Ł. Komsta (Medical University of Lublin, Lublin, Poland)
P. Kus (Univerity of Silesia, Katowice, Poland)
D. Mangelings (Free University of Brussels, Brussels, Belgium)
E. Mincsovics (Corvinus University of Budapest, Budapest, Hungary)
G. Morlock (Giessen University, Giessen, Germany)
J. Sherma (Lafayette College, Easton, PA, USA)
R. Skibiński (Medical University of Lublin, Lublin, Poland)
B. Spangenberg (Offenburg University of Applied Sciences, Germany)
T. Tuzimski (Medical University of Lublin, Lublin, Poland)
Y. Vander Heyden (Free University of Brussels, Brussels, Belgium)
A. Voelkel (Poznań University of Technology, Poznań, Poland)
B. Walczak (University of Silesia, Katowice, Poland)
W. Wasiak (Adam Mickiewicz University, Poznań, Poland)

KOWALSKA, TERESA
E-mail: kowalska@us.edu.pl

SAJEWICZ, MIECZYSLAW
E-mail:msajewic@us.edu.pl

Indexing and Abstracting Services:

  • Science Citation Index
  • Sci Search
  • Research Alert
  • Chemistry Citation Index and Current Content/Physical
  • Chemical and Earth Sciences
  • SCOPUS
  • GoogleScholar
  • Index Copernicus
  • CABI
2020
 
Total Cites
650
WoS
Journal
Impact Factor
1,639
Rank by
Chemistry, Analytical 71/83 (Q4)
Impact Factor
 
Impact Factor
1,412
without
Journal Self Cites
5 Year
1,301
Impact Factor
Journal
0,34
Citation Indicator
 
Rank by Journal
Chemistry, Analytical 75/93 (Q4)
Citation Indicator
 
Citable
45
Items
Total
43
Articles
Total
2
Reviews
Scimago
28
H-index
Scimago
0,316
Journal Rank
Scimago
Chemistry (miscellaneous) Q3
Quartile Score
 
Scopus
393/181=2,2
Scite Score
 
Scopus
General Chemistry 215/398 (Q3)
Scite Score Rank
 
Scopus
0,560
SNIP
 
Days from
58
sumbission
 
to acceptance
 
Days from
68
acceptance
 
to publication
 
Acceptance
51%
Rate

2019  
Total Cites
WoS
495
Impact Factor 1,418
Impact Factor
without
Journal Self Cites
1,374
5 Year
Impact Factor
0,936
Immediacy
Index
0,460
Citable
Items
50
Total
Articles
50
Total
Reviews
0
Cited
Half-Life
6,2
Citing
Half-Life
8,3
Eigenfactor
Score
0,00048
Article Influence
Score
0,164
% Articles
in
Citable Items
100,00
Normalized
Eigenfactor
0,05895
Average
IF
Percentile
20,349
Scimago
H-index
26
Scimago
Journal Rank
0,255
Scopus
Scite Score
226/167=1,4
Scopus
Scite Score Rank
Chemistry (miscellaneous) 240/398 (Q3)
Scopus
SNIP
0,494
Acceptance
Rate
41%

 

Acta Chromatographica
Publication Model Online only
Gold Open Access
Submission Fee none
Article Processing Charge 400 EUR/article
Regional discounts on country of the funding agency World Bank Lower-middle-income economies: 50%
World Bank Low-income economies: 100%
Further Discounts Editorial Board / Advisory Board members: 50%
Corresponding authors, affiliated to an EISZ member institution subscribing to the journal package of Akadémiai Kiadó: 100%
Subscription Information Gold Open Access
Purchase per Title  

Acta Chromatographica
Language English
Size A4
Year of
Foundation
1992
Publication
Programme
2021 Volume 33
Volumes
per Year
1
Issues
per Year
4
Founder Institute of Chemistry, University of Silesia
Founder's
Address
PL-40-007 Katowice, Poland, Bankowa 12
Publisher Akadémiai Kiadó
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 2083-5736 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
May 2021 0 32 23
Jun 2021 0 26 25
Jul 2021 0 40 31
Aug 2021 0 34 29
Sep 2021 0 41 42
Oct 2021 0 14 12
Nov 2021 0 0 0