Authors:
Takashi Abe Graduate School of Health and Sports Science & Institute of Health and Sports Science and Medicine, Juntendo University, Inzai, Chiba 270-1695, Japan
Division of Children's Health and Exercise Research, Institute of Trainology, Sawara, Fukuoka, Fukuoka 814-0001, Japan

Search for other papers by Takashi Abe in
Current site
Google Scholar
PubMed
Close
https://orcid.org/0000-0003-0568-1004
,
Hayao Ozaki School of Sport and Health Sciences, Tokai Gakuen University, Miyoshi, Aichi 470-0207, Japan

Search for other papers by Hayao Ozaki in
Current site
Google Scholar
PubMed
Close
,
Akemi Abe Division of Children's Health and Exercise Research, Institute of Trainology, Sawara, Fukuoka, Fukuoka 814-0001, Japan

Search for other papers by Akemi Abe in
Current site
Google Scholar
PubMed
Close
, and
Jeremy P. Loenneke Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA

Search for other papers by Jeremy P. Loenneke in
Current site
Google Scholar
PubMed
Close
Open access

Abstract

Background and Aim

It was unknown whether ultrasound-measured forearm muscle thickness was impacted by pronation of the forearm. The aim of this study was to investigate the influence of forearm pronation on two forearm muscle thicknesses (MT-ulna and MT-radius).

Participants and Methods

Fourteen healthy children and adolescents sat on a chair with their right arm comfortably on a table, and their hands were fixed to the board with elastic bands. The probe was placed perpendicularly over the forearm, and the angle of the board was then pronated in 5° increments from −10° to 30°. The average value of the two measures at each angle was used.

Results

There was evidence that MT-ulna differed across measurement sites (F = 51.086, P < 0.001). For example, the values of the MT-ulna were 2.58 (SD 0.40) cm in standard position (0°), 2.56 (SD 0.41) in −10°, 2.62 (SD 0.41) in 10°, 2.65 (SD 0.42) in 20°, and 2.71 (SD 0.43) in 30°. Follow-up tests found that all sites differed from each other except for −10° and −5° (P = 0.155) and 10° and 15° (P = 0.075). There was also evidence that the MT-radius differed across measurement sites (F = 22.07, P < 0.001). Follow-up tests found that many but not all sites differed from each other.

Conclusion

Our results suggest that MT-ulna increases and MT-radius decreases due to forearm pronation from the standard position (0°). When determining the forearm position using the 95% limits of agreement, we recommend the forearm position within ±5° of the standard forearm position when measuring forearm MT.

Abstract

Background and Aim

It was unknown whether ultrasound-measured forearm muscle thickness was impacted by pronation of the forearm. The aim of this study was to investigate the influence of forearm pronation on two forearm muscle thicknesses (MT-ulna and MT-radius).

Participants and Methods

Fourteen healthy children and adolescents sat on a chair with their right arm comfortably on a table, and their hands were fixed to the board with elastic bands. The probe was placed perpendicularly over the forearm, and the angle of the board was then pronated in 5° increments from −10° to 30°. The average value of the two measures at each angle was used.

Results

There was evidence that MT-ulna differed across measurement sites (F = 51.086, P < 0.001). For example, the values of the MT-ulna were 2.58 (SD 0.40) cm in standard position (0°), 2.56 (SD 0.41) in −10°, 2.62 (SD 0.41) in 10°, 2.65 (SD 0.42) in 20°, and 2.71 (SD 0.43) in 30°. Follow-up tests found that all sites differed from each other except for −10° and −5° (P = 0.155) and 10° and 15° (P = 0.075). There was also evidence that the MT-radius differed across measurement sites (F = 22.07, P < 0.001). Follow-up tests found that many but not all sites differed from each other.

Conclusion

Our results suggest that MT-ulna increases and MT-radius decreases due to forearm pronation from the standard position (0°). When determining the forearm position using the 95% limits of agreement, we recommend the forearm position within ±5° of the standard forearm position when measuring forearm MT.

Introduction

Ultrasound is a useful imaging technique to assess the subcutaneous adipose tissue and muscle sizes of the upper and lower extremities and the trunk [1, 2]. In larger human muscle, however, a single ultrasound image can measure only muscle thickness (MT), not muscle cross-sectional area or muscle volume. In addition, approximately 20 muscles are placed around the two bones of the forearm, and two major extrinsic flexor muscles of the fingers, i.e., flexor digitorum profundus and flexor digitorum superficialis, are located near the ulna of the upper portion of the forearm [3]. However, there are various shapes in those two muscles, and the boundary surrounding those two muscles is not visualized with the ultrasound [4]. Therefore, MT may be desirable when assessing the muscle size of the extrinsic forearm flexor muscle of the fingers, although those are relatively small-sized muscles. In forearm-supination, the radius is parallel to the ulna, whereas the radius crosses the ulna in the pronation of the forearm. Thus, setting the forearm in the pronation or supination during ultrasound measurement may change the MT. Unlike adults, it may not be possible to maintain the forearm-position during ultrasound measurements in young children.

Previous studies have provided inconsistent conditions on forearm-position during ultrasound measurements. For example, some studies do not describe the forearm-position during ultrasound measurements [5–9]. Studies from our group and others have stated that the forearm MT was measured while participants were standing or supine with the forearm-supinated [10–13]. However, if the measured value of forearm MT changes when the degree of supination of the forearm is slightly different, the accurate ultrasonic measurement will not be possible. For example, if the value differs then estimations of appendicular lean mass from MT of the forearm may lead to erroneous results if the assessment is made in a position different from the original validation [10, 14]. It could also impact the comparison across studies. Therefore, it is important to better understand the influence of forearm-pronation on MT values of the forearm. In the present study, we investigated the impact of forearm-pronation on ultrasound-measured forearm MT in children and adolescents.

Participants and methods

Participants

In this study, fourteen healthy volunteers (6 females) aged 3–11 years [mean age, 7.6 (SD 2.3) years old] were recruited through printed advertisement and by word of mouth. Exclusion criteria were as follows: history of surgery of the upper limbs, cardiometabolic, orthopedic, and neuromuscular diseases. Volunteers with their parents were fully informed about the purpose of the study and its safety and written informed consent was obtained from the parents of each volunteer. This study was approved by the University's Institutional Review Board (HSS-#29-17) and complies with the Helsinki Declaration.

Forearm MT measurements

Participants rested on a chair with their right arm comfortably on a table at an elbow joint angle of approximately 10° (0° at full extension) and their forearm supinated. Additionally, an expanded polystyrene board (7-mm thickness) was placed between the forearm and the table, and the four fingers except for the thumb and the palm were fixed to the board with elastic bands (Fig. 1). The board was separated into two parts (one panel on the forearm and another on the hand), and the top (on which the hand rested) was designed to rotate.

Fig. 1.
Fig. 1.

Experimental setup used in this study. An expanded polystyrene board (7 mm thickness) was separated into two parts, and the top (on which the hand rested) was designed to rotate. The electronic level (bottom left of the photo) was first calibrated for each individual, and 0° was a parallel of the two boards on the forearm and hand. The ultrasound probe was never taken off the surface of the skin until all images were taken. The right side of the figure is a typical ultrasound image at each angle

Citation: Imaging 14, 2; 10.1556/1647.2022.00074

A B-mode ultrasound (Logiq-e; GE, Fairfield, CT, USA) was used to take a total of 18 ultrasound images (9-images, twice) at the anterior forearm. The ultrasound images were taken at 30% proximal of the distance between the styloid process and the head of the radius. The forearm-pronation was assessed using a small electronic level with a digital readout (Level Box, UJK technologies, USA) attached to the top of the panel. The electronic level was first calibrated for each individual, and 0° (standard position) was determined to be when the two panels on the forearm and hand were flat (as illustrated in Fig. 1). The probe was coated with a transmission gel and placed perpendicular over the forearm, and the angle of the panel which on the hand rested was then pronated in 5° increments from −10° to 30°, and the first image was always taken at −10°. One image at each angle was stored in the ultrasound. The probe was never taken off the surface of the skin until all images were taken (a total of 9-images). Two MTs were determined as the perpendicular distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the ulna (MT-ulna) and radius (MT-radius). The distance between the two interfaces was measured with an electronic caliper of the ultrasound. Each individual performed this series of measurements twice to assess MT change, and the average value of the two measures at each angle was used for data analysis.

Reliability of forearm muscle thickness measurements

Test-retest reliability of MT-ulna and MT-radius measurements using the intraclass correlation coefficient (ICC3.1), standard error of measurement, and the minimal difference (i.e. absolute reliability) was determined for data from a different group of 13 children (7 boys and 6 girls, age range 3.9–6.5 years) measured twice, four weeks apart before the study. The measurements were performed in the morning (9:30–11:00 am) using the same methodological protocols described above, and the forearm-position was 0°.

Statistical analysis

All statistical analyses were completed using jamovi (The jamovi project version-1.6.23). The individual plot figures were created using JASP version-0.16. Test-retest reliability was determined by calculating the difference between the value from the initial test to that of the retest. The standard deviation (SD) of that difference was divided by the square root of 2 in order to calculate the standard error of the measurement. The minimal difference (i.e. absolute reliability) was calculated by multiplying the SD of the difference by 1.96. Limits of agreement (95% level) were set by adding and subtracting the minimal difference value from the mean difference.

Differences in MT between sites were determined using a one-way repeated measures ANOVA. If there was a significant overall test, follow-up pairwise comparisons were made in order to determine where the differences were. Statistical significance was set at ≤0.05, however, more emphasis was placed on the size of the difference and the variability of that difference. Differences from “0°” with 95% limits of agreement were plotted to visually show agreement across sites.

Results

Change in muscle thickness by forearm pronation

There was evidence that MT-ulna differed across measurement sites (F = 51.086, P < 0.001). For example, the values of the MT-ulna were 2.58 (SD 0.40) cm in standard position (0°), 2.56 (SD 0.41) in −10°, 2.62 (SD 0.41) in 10°, 2.65 (SD 0.42) in 20°, and 2.71 (SD 0.43) in 30°. Follow-up tests found that all sites differed from each other (Fig. 2A) except for −10 and −5 (P = 0.155) and 10 and 15 (P = 0.075). There was also evidence that the MT-radius differed across measurement sites (F = 22.07, P < 0.001). For example, the values of the MT-radius were 1.24 (SD 0.24) cm in standard position (0°), 1.28 (SD 0.27) in −10°, 1.22 (SD 0.24) in 10°, 1.21 (SD 0.23) in 20°, and 1.19 (SD 0.23) in 30°. Follow-up tests found that many but not all sites differed from each other (Fig. 2B). Limits of agreement for each site compared with “0” is illustrated in Fig. 3A for the ulna and Fig. 3B for the radius.

Fig. 2.
Fig. 2.

Individual muscle thickness values at each site for the ulna (panel A) and radius (panel b). The box plot represents the interquartile range of the muscle thickness at each specific degree (−10 to 30°). Letters indicate significant differences between sites. If conditions share the same letter they are not different from one another. Alpha level = 0.05

Citation: Imaging 14, 2; 10.1556/1647.2022.00074

Fig. 3.
Fig. 3.

The differences in forearm muscle thickness (cm) from the standard position (0° minus the value at the other site) and 95% limits of agreement at each angle of the forearm pronation (panel A, ulna; panel B, radius). Notably, the test-retest data is included on the figure as dotted lines to show how the current difference compares with the agreement from the same site measured twice. The middle-dotted line represents the bias between test-retest and the upper and lower dotted lines represent the upper and lower bounds

Citation: Imaging 14, 2; 10.1556/1647.2022.00074

Test-retest reliability

A paired t-test revealed no significant differences between test [2.26 (SD 0.5) cm] and retest [2.25 (SD 0.16) cm] for MT-ulna and between test [1.07 (SD 0.10) cm] and retest [1.03 (SD 0.11) cm] for MT-radius. The mean difference was 0.005 (SD 0.031) cm for MT-ulna and 0.035 (SD 0.04) cm for MT-radius. The correlation coefficient between the two measurements was 0.981 and 0.936, respectively. The standard error of measurement and the minimal difference was 0.022 and 0.061 cm for MT-ulna and 0.028 and 0.078 cm for MT-radius. The 95% limits of agreement were −0.050 to 0.065 cm and −0.04 to 0.11 cm, respectively.

Discussion

The current study investigated the impact of forearm pronation on ultrasound-measured forearm MT in children and adolescents. Our results showed that forearm MT-ulna and MT-radius differed across measurement sites, i.e. MT-ulna increases and MT-radius decreases due to forearm pronation from the standard position (0°). The standard position of the forearm in this study was set as a participant sitting on a chair with one arm forward and palms up, and the hand was parallel to the desk. Therefore, when measuring forearm MT using ultrasound, it is necessary to set all participants with the same forearm-position.

Previous studies [5–9] did not describe clear conditions for forearm-position during ultrasound measurements. In our experience, it is not always possible to maintain the forearm-position when testing in a non-laboratory setting such as a pre-school. In the current study, the participants had their hands fixed to a dedicated board using elastic bands and were instructed not to move their upper bodies during the ultrasound measurements. The same ultrasound image is generally used to analyze two forearm MTs together, i.e., MT-ulna and MT-radius. The limits of agreement suggest that values plus/minus 5 degrees of the standard position produce reasonable estimates for both the MT-ulna and MT-radius. The error starts to increase when going beyond this point of rotation.

In conclusion, our results showed that forearm MT differed across measurement sites, i.e. MT-ulna increases and MT-radius decreases due to forearm pronation from the standard position (0°). When determining the forearm-position using the 95% limits of agreement, our results recommended the forearm-position within ±5° of the standard position of the forearm when measuring forearm MT.

Authors' contributions

Conceived and designed the study: TA, HO, AA, and JPL. Performed the data collection: TA, HO, and AA. Analyzed the data: TA and JPL. Wrote the manuscript: TA. Reviewed and critically revised the manuscript: HO, AA, and JPL. All authors approved the final version of the manuscript.

Conflict of interest

The authors declare no conflicts of interest.

Funding sources

This study received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.

Acknowledgments

The authors are grateful to all the children and adolescents who took part in this study, their caregivers, and all the supporting staff of this study.

References

  • [1]

    Abe T, Wong V, Bell ZW, Spitz RW, Dankel SJ, Loenneke JP: Subcutaneous adipose tissue distribution and serum lipid/lipoprotein in unmedicated postmenopausal women: A B-mode ultrasound study. Imaging 2021; 13: 119123.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [2]

    Abe T, Loenneke JP, Thiebaud RS, Loftin M: Morphological and functional relationships with ultrasound measured muscle thickness of the upper extremity and trunk. Ultrasound 2014; 22: 229235.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [3]

    Saladin KS: Anatomy & physiology. The unity of form and function. 3rd eds., McGraw-Hill, New York, 2004.

  • [4]

    Abe T, Loenneke JP: Author's response. Assessing forearm muscle size with ultrasound. Clin Physiol Func Imaging 2018; 38: 10691070.

  • [5]

    Ishida Y, Carroll JF, Pollock ML, Graves JE, Leggett SH: Reliability of B-mode ultrasound for the measurement of body fat and muscle thickness. Am J Hum Biol 1992; 4: 511520.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [6]

    Arts IMP, Pillen S, Schelhaas HJ, Overeem S, Zwarts MJ: Normal values for quantitative muscle ultrasonography in adults. Muscle Nerve 2010; 41: 3241.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [7]

    English CK, Thoirs KA, Fisher L, McLennan H, Bernhardt J: Ultrasound is a reliable measure of muscle thickness in acute stroke patients, for some, but not all anatomical sites: a study of the intra-rater reliability of muscle thickness measures in acute stroke patients. Ultrasound Med Biol 2012; 38: 368376.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [8]

    Morimoto A, Suga T, Tottori N, Wachi M, Misaki J, Tsuchikane R, et al.: Association between hand muscle thickness and whole-body skeletal muscle mass in healthy adults: A pilot study. J Phys Ther Sci 2017; 29: 16441648.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [9]

    Marinez-Paya J, del Mono-Aledo ME, Rios-Diaz J, Tembl-Ferrairo JI, Vazquez-Costa JF, Medina-Mirapeix F: Muscular echovariation: A new biomarker in amyotrophic lateral sclerosis. Ultrasound Med Biol 2017; 43: 11531162.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [10]

    Abe T, Loenneke JP, Thiebaud RS, Fujita E, Akamine T, Loftin M: Prediction and validation of DXA-derived appendicular fat-free adipose tissue by a single ultrasound image of the forearm in Japanese older adults. J Ultrasound Med 2018; 37: 347353.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [11]

    Lori S, Lolli F, Molesti E, Bastianelli M, Gabbanini S, Saia V, et al.: Muscle-ultrasound evaluation in healthy paediatric subjects: Age-related normative data. Muscle Nerve 2018; 58: 245250.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [12]

    Lambell KJ, Tierney AC, Wang JC, Nanjayya V, Forsyth A, Goh GS, et al.: Comparison of ultrasound-derived muscle thickness with computed tomography muscle cross-sectional area on admission to the intensive care unit: A pilot cross-sectional study. JPEN J Parenter Enteral Nutr 2021; 45: 136145.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [13]

    Ozaki H, Abe T, Dankel SJ, Loenneke JP, Natsume T, Deng P, et al.: The measurement of strength in children: Is the peak value truly maximal? Children 2021; 8: 9.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [14]

    Abe T, Loenneke JP, Thiebaud RS, Fujita E, Akamine T: The impact of DXA-derived fat-free adipose tissue on the prevalence of low muscle mass in older adults. Eur J Clin Nutr 2019; 73: 757762.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [1]

    Abe T, Wong V, Bell ZW, Spitz RW, Dankel SJ, Loenneke JP: Subcutaneous adipose tissue distribution and serum lipid/lipoprotein in unmedicated postmenopausal women: A B-mode ultrasound study. Imaging 2021; 13: 119123.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [2]

    Abe T, Loenneke JP, Thiebaud RS, Loftin M: Morphological and functional relationships with ultrasound measured muscle thickness of the upper extremity and trunk. Ultrasound 2014; 22: 229235.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [3]

    Saladin KS: Anatomy & physiology. The unity of form and function. 3rd eds., McGraw-Hill, New York, 2004.

  • [4]

    Abe T, Loenneke JP: Author's response. Assessing forearm muscle size with ultrasound. Clin Physiol Func Imaging 2018; 38: 10691070.

  • [5]

    Ishida Y, Carroll JF, Pollock ML, Graves JE, Leggett SH: Reliability of B-mode ultrasound for the measurement of body fat and muscle thickness. Am J Hum Biol 1992; 4: 511520.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [6]

    Arts IMP, Pillen S, Schelhaas HJ, Overeem S, Zwarts MJ: Normal values for quantitative muscle ultrasonography in adults. Muscle Nerve 2010; 41: 3241.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [7]

    English CK, Thoirs KA, Fisher L, McLennan H, Bernhardt J: Ultrasound is a reliable measure of muscle thickness in acute stroke patients, for some, but not all anatomical sites: a study of the intra-rater reliability of muscle thickness measures in acute stroke patients. Ultrasound Med Biol 2012; 38: 368376.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [8]

    Morimoto A, Suga T, Tottori N, Wachi M, Misaki J, Tsuchikane R, et al.: Association between hand muscle thickness and whole-body skeletal muscle mass in healthy adults: A pilot study. J Phys Ther Sci 2017; 29: 16441648.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [9]

    Marinez-Paya J, del Mono-Aledo ME, Rios-Diaz J, Tembl-Ferrairo JI, Vazquez-Costa JF, Medina-Mirapeix F: Muscular echovariation: A new biomarker in amyotrophic lateral sclerosis. Ultrasound Med Biol 2017; 43: 11531162.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [10]

    Abe T, Loenneke JP, Thiebaud RS, Fujita E, Akamine T, Loftin M: Prediction and validation of DXA-derived appendicular fat-free adipose tissue by a single ultrasound image of the forearm in Japanese older adults. J Ultrasound Med 2018; 37: 347353.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [11]

    Lori S, Lolli F, Molesti E, Bastianelli M, Gabbanini S, Saia V, et al.: Muscle-ultrasound evaluation in healthy paediatric subjects: Age-related normative data. Muscle Nerve 2018; 58: 245250.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [12]

    Lambell KJ, Tierney AC, Wang JC, Nanjayya V, Forsyth A, Goh GS, et al.: Comparison of ultrasound-derived muscle thickness with computed tomography muscle cross-sectional area on admission to the intensive care unit: A pilot cross-sectional study. JPEN J Parenter Enteral Nutr 2021; 45: 136145.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [13]

    Ozaki H, Abe T, Dankel SJ, Loenneke JP, Natsume T, Deng P, et al.: The measurement of strength in children: Is the peak value truly maximal? Children 2021; 8: 9.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [14]

    Abe T, Loenneke JP, Thiebaud RS, Fujita E, Akamine T: The impact of DXA-derived fat-free adipose tissue on the prevalence of low muscle mass in older adults. Eur J Clin Nutr 2019; 73: 757762.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • Collapse
  • Expand

 

The author instruction is available in PDF.
Please, download the file from HERE.
 
The Open Access statement together with the description of the Copyright and License Policy are available in PDF.
Please, download the file from HERE.


 

Chair of the Editorial Board:
Béla MERKELY (Semmelweis University, Budapest, Hungary)

Editor-in-Chief:
Pál MAUROVICH-HORVAT (Semmelweis University, Budapest, Hungary)

Deputy Editor-in-Chief:
Viktor BÉRCZI (Semmelweis University, Budapest, Hungary)

Executive Editor:
Charles S. WHITE (University of Maryland, USA)

Deputy Editors:
Gianluca PONTONE (Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy)
Michelle WILLIAMS (University of Edinburgh, UK)

Senior Associate Editors:
Tamás Zsigmond KINCSES (University of Szeged, Hungary)
Hildo LAMB (Leiden University, The Netherlands)
Denisa MURARU (Istituto Auxologico Italiano, IRCCS, Milan, Italy)
Ronak RAJANI (Guy’s and St Thomas’ NHS Foundation Trust, London, UK)

Associate Editors:
Andrea BAGGIANO (Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy)
Fabian BAMBERG (Department of Radiology, University Hospital Freiburg, Germany)
Péter BARSI (Semmelweis University, Budapest, Hungary)
Theodora BENEDEK (University of Medicine, Pharmacy, Sciences and Technology, Targu Mures, Romania)
Ronny BÜCHEL (University Hospital Zürich, Switzerland)
Filippo CADEMARTIRI (SDN IRCCS, Naples, Italy) Matteo CAMELI (University of Siena, Italy)
Csilla CELENG (University of Utrecht, The Netherlands)
Edit DÓSA (Semmelweis University, Budapest, Hungary)
Marco FRANCONE (La Sapienza University of Rome, Italy)
Viktor GÁL (OrthoPred Ltd., Győr, Hungary)
Alessia GIMELLI (Fondazione Toscana Gabriele Monasterio, Pisa, Italy)
Tamás GYÖRKE (Semmelweis Unversity, Budapest)
Fabian HYAFIL (European Hospital Georges Pompidou, Paris, France)
György JERMENDY (Bajcsy-Zsilinszky Hospital, Budapest, Hungary)
Pál KAPOSI (Semmelweis University, Budapest, Hungary)
Mihaly KÁROLYI (University of Zürich, Switzerland)
Lajos KOZÁK (Semmelweis University, Budapest, Hungary)
Mariusz KRUK (Institute of Cardiology, Warsaw, Poland)
Zsuzsa LÉNARD (Semmelweis University, Budapest, Hungary)
Erica MAFFEI (ASUR Marche, Urbino, Marche, Italy)
Robert MANKA (University Hospital, Zürich, Switzerland)
Saima MUSHTAQ (Cardiology Center Monzino (IRCCS), Milan, Italy)
Gábor RUDAS (Semmelweis University, Budapest, Hungary)
Balázs RUZSICS (Royal Liverpool and Broadgreen University Hospital, UK)
Christopher L SCHLETT (Unievrsity Hospital Freiburg, Germany)
Bálint SZILVESZTER (Semmelweis University, Budapest, Hungary)
Richard TAKX (University Medical Centre, Utrecht, The Netherlands)
Ádám TÁRNOKI (National Institute of Oncology, Budapest, Hungary)
Dávid TÁRNOKI (National Institute of Oncology, Budapest, Hungary)
Ákos VARGA-SZEMES (Medical University of South Carolina, USA)
Hajnalka VÁGÓ (Semmelweis University, Budapest, Hungary)
Jiayin ZHANG (Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China)

International Editorial Board:

Gergely ÁGOSTON (University of Szeged, Hungary)
Anna BARITUSSIO (University of Padova, Italy)
Bostjan BERLOT (University Medical Centre, Ljubljana, Slovenia)
Edoardo CONTE (Centro Cardiologico Monzino IRCCS, Milan)
Réka FALUDI (University of Szeged, Hungary)
Andrea Igoren GUARICCI (University of Bari, Italy)
Marco GUGLIELMO (Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy)
Kristóf HISRCHBERG (University of Heidelberg, Germany)
Dénes HORVÁTHY (Semmelweis University, Budapest, Hungary)
Julia KARADY (Harvard Unversity, MA, USA)
Attila KOVÁCS (Semmelweis University, Budapest, Hungary)
Riccardo LIGA (Cardiothoracic and Vascular Department, Università di Pisa, Pisa, Italy)
Máté MAGYAR (Semmelweis University, Budapest, Hungary)
Giuseppe MUSCOGIURI (Centro Cardiologico Monzino IRCCS, Milan, Italy)
Anikó I NAGY (Semmelweis University, Budapest, Hungary)
Liliána SZABÓ (Semmelweis University, Budapest, Hungary)
Özge TOK (Memorial Bahcelievler Hospital, Istanbul, Turkey)
Márton TOKODI (Semmelweis University, Budapest, Hungary)

Managing Editor:
Anikó HEGEDÜS (Semmelweis University, Budapest, Hungary)

Pál Maurovich-Horvat, MD, PhD, MPH, Editor-in-Chief

Semmelweis University, Medical Imaging Centre
2 Korányi Sándor utca, Budapest, H-1083, Hungary
Tel: +36-20-663-2485
E-mail: maurovich-horvat.pal@med.semmelweis-univ.hu

Indexing and Abstracting Services:

  • WoS Emerging Science Citation Index
  • Scopus
  • DOAJ

2022  
Web of Science  
Total Cites
WoS
65
Journal Impact Factor 0.4
Rank by Impact Factor

n/a

Impact Factor
without
Journal Self Cites
0.3
5 Year
Impact Factor
0.8
Journal Citation Indicator 0.06
Rank by Journal Citation Indicator

Medicine, General & Internal (Q4)

Scimago  
Scimago
H-index
18
Scimago
Journal Rank
0.171
Scimago Quartile Score

Medicine (miscellanous) (Q4)
Radiological and Ultrasound Technology (Q4)
Radiology, Nuclear Medicine and Imaging (Q4)

Scopus  
Scopus
Cite Score
1.0
Scopus
CIte Score Rank
Medicine (miscellaneous) 221/309 (28th PCTL)
Radiological and Ultrasound Technology 45/58 (23rd PCTL)
Radiology, Nuclear Medicine and Imaging 242/312 (22nd PCTL)
Scopus
SNIP
0.354

2021  
Web of Science  
Total Cites
WoS
56
Journal Impact Factor not applicable
Rank by Impact Factor

not applicable

Impact Factor
without
Journal Self Cites
not applicable
5 Year
Impact Factor
not applicable
Journal Citation Indicator 0,10
Rank by Journal Citation Indicator

Medicine, General & Internal 236/329

Scimago  
Scimago
H-index
16
Scimago
Journal Rank
0,226
Scimago Quartile Score Medicine (miscellaneous) (Q4)
Radiological and Ultrasound Technology (Q4)
Radiology, Nuclear Medicine and Imaging (Q4)
Scopus  
Scopus
Cite Score
1,6
Scopus
CIte Score Rank
Medicine (miscellaneous) 175/276 (Q3)
Radiology, Nuclear Medicine and Imaging 209/308 (Q3)
Radiological and Ultrasound Technology 42/60 (Q3)
Scopus
SNIP
0,451

2020  
CrossRef Documents 7
CrossRef Cites 0
CrossRef H-index 1
Days from submission to acceptance 17
Days from acceptance to publication 70
Acceptance Rate 43%

Imaging
Publication Model Gold Open Access
Submission Fee none
Article Processing Charge none
Subscription Information Gold Open Access

Imaging
Language English
Size A4
Year of
Foundation
2020 (2009)
Volumes
per Year
1
Issues
per Year
2
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 2732-0960 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Jun 2023 0 14 14
Jul 2023 0 15 12
Aug 2023 0 27 14
Sep 2023 0 24 22
Oct 2023 0 21 10
Nov 2023 0 35 15
Dec 2023 0 0 0