Main aim of this paper is to illustrate the experimental partial results of a study on various exterior wall fragments. The study was performed for selected wall fragments and time periods, with attention focused also on wall orientation (East and South) with identical layering and also on dynamic thermal parameters connected to the thermal comfort during summer and winter. Evaluation is done for real measured climate conditions in the area of experimental laboratory (exterior – University of Zilina) and interior conditions set according to the Slovak standard. For needs of the long-term experiment (since March 2017), temperature and relative humidity between layers are monitored. This paper deals specifically with the temperature measurement of selected days. For future publications also coupled heat-air-moisture transport analysis is intended. In this part of analysis, some extreme boundary conditions were selected and reviewed from the point of view of measured temperature inside the wall. Temperature peaks are characterized with respect to exposure to real atmospheric conditions.

  • [1]

    Ozbalta T. G. , Ozbalta N. (2010), The effects of insulation location and thermos-physical properties of various external wall materials on decrement factor and time lag. Scientific Research and Essays, 5 (23), 36463659.

    • Search Google Scholar
    • Export Citation
  • [2]

    Lupisek A. , et al. (2015), Design Strategies for Low Embodied Carbon and Low Embodied Energy Buildings: Principles and Examples. Energy Procedia 83. Elsevier, pp. 147156.

    • Search Google Scholar
    • Export Citation
  • [3]

    Cekon M. , Slavik R., Zach J. (2017), Experimental Analysis of Transparent Insulation Based on Polycarbonate Multi-Wall Systems: Thermal and Optical Performance. Energy Procedia 132. Elsevier, pp. 502507.

    • Search Google Scholar
    • Export Citation
  • [4]

    Alhawari A. , Mukhopadhayaya P. (2018), Thermal bridges in building envelopes – an overview of impacts and solutions. Int. Rev. Appl. Sci. Eng., 9, 3140.

    • Search Google Scholar
    • Export Citation
  • [5]

    Vertal M. , et al. (2018), Hygrothermal initial condition for simulation process of green building construction. Energy and Buildings, 167, 166176.

    • Search Google Scholar
    • Export Citation
  • [6]

    Larsen S. F. , Filipin C., Lesino G. (2009), Thermal behaviour of building walls in summer: Comparison of available analytical methods and experimental results for a case study. Building Simulation, 2, 318.

    • Search Google Scholar
    • Export Citation
  • [7]

    Staffenova D. , et al. (2017), Intention, principle and aims of the experimental pavilion research of building envelopes including windows for wooden buildings. Civil and Environmental Engineering, 13, 4251.

    • Search Google Scholar
    • Export Citation
  • [8]

    Ozel M. , Ozel C. (2012), Effects of wall orientation and thermal insulation on time lag and decrement factor. HEFAT2012. Malta.

  • [9]

    Kontoleon K. J. , Bikas D. K. (2005), Thermal mass vs. thermal response factors: determining optimal geometrical properties and envelope assemblies of building materials. Passive and Low Energy Cooling for the Built Environment. Greece.

    • Search Google Scholar
    • Export Citation
  • [10]

    Balaji N. C. , et al. (2013), Thermal Performance of the Building Walls. 1st IBPSA Italy Conference.

  • [11]

    Radon J. , et al. (2017), Experimental and theoretical study on hygrothermal long-term performance of outer assemblies in lightweight passive house. Journal of Building Physics, 299320.

    • Search Google Scholar
    • Export Citation