Nosocomial infections are one of the most common causes of death in hospitals. This study aimed to determine the prevalence of gram-negative bacilli isolated from the equipment in hospital wards of the Golestan province, in the year 2015. In this crosssectional study in 2015, 1980 samples from medical and nonmedical equipment and surfaces were collected from the wards of 13 teaching hospitals, in the Golestan province. Samples were inoculated into eosin methylene blue agar and blood agar culture media and isolated colonies were identified by standard biochemical tests. The obtained results were then analyzed using SPSS 22 software and χ2 test. Among 1980 isolated samples, 601 samples (30.35%) were infected with gram-negative bacilli while Enterobacter aerogenes (37.27%) was responsible for most of the contaminations. The highest rate of infection was observed in the intensive care unit (33.1%), and the highest level of contamination in the medical equipment was associated with laryngoscope and its blade (10.48%), as well as ECG sensor and its monitoring connector (6.65%). Meanwhile, phone (6.32%) and patients’ beds and linen (5.15%) had the highest level of contamination in the nonmedical equipment. Considering the high rates of gram-negative bacilli contamination in the hospital wards of the Golestan province, thorough hand washing as the main action for disinfection and sterilizing the equipment, as well as performing periodic cultivation alongside the use of standard guidelines for prevention and control of nosocomial infections, are recommended to reduce the level of contamination.
Taheri N , Abtahi H, Amozande-Nobaveh A, Zarinfar N, Ghaznavi-Rad E: The antibiotic resistant determinant of pathogenic bacteria isolated from medical equipment and hospital environment in Valiasr Hospital, Arak, 2013. J Mazand Univ Med Sci 24(114), 60–73 (2014)
Khosravi A , Parhizgari N, Abbasi Montazeri E, Mozaffari A, Abbasi F: The prevalence of bacteria isolated from endotracheal tubes of patients in Golestan Hospital, Ahvaz, Iran, and determination of their antibiotic susceptibility patterns. Jundishapur J Microbiol 6(1), 67–71 (2013)
Muhammad UK , Isa MA, Aliyu ZM: Distribution of potential nosocomial pathogens isolated from environments of four selected hospitals in Sokoto, North Western Nigeria. J Microbiol Biotech Res 3(1), 139–143 (2013)
Nobahar M , Vafaei AA: Survey of contamination stethoscopes as one of the factor for nosocomial infections: transmission in educational hospitals in Semnan city. Iran J Infect Dis Trop Med 8(23), 25–28 (2004)
Peleg AY , Hooper DC: Hospital acquired infections due to gram-negative bacteria. N Engl J Med 362(19), 1804–1813 (2010)
Amirmozafari N , Forouhesh Tehrani H, Mohebbi S: Survey genus and species of non- fermentative gram negative bacilli isolated from hospitalized patients. J Guilan Univ Med Sci 16(64), 67–75 (2008)
Moniri R , Momen Heravi M: Evaluation of bacterial contamination in medical devices and anti-bacterial resistance of isolated gram negative bacilli in Shahid Beheshti Hospital in Kashan, Iran, 2004. Feyz 9(36), 50–55 (2006)
Aslani Y , Saadat M, Etemadifar SH, Fazeli SM: The evaluation of different hospital equipment microbial contamination in medical training center Hajar of Shahrekord. Hamdan Nurs Midwifery Fac 17(12), 19–23 (2009)
Hall GS , Woods GL (2011): Medical Bacteriology. In: Henry’s Clinical Diagnosis and Management by Laboratory Methods, 22nd edn., eds. McPherson RA, Pincus MR, Saunders Elsevier, Philadelphia, pp. 1079–1115
Amanlou S , Farjah GHH, Taghavi MR, Kolarastagh H, Jahantigh HA, Sabouri GHR: Microbial contamination of operation rooms in Amir-Al-Momenin Hospital of Zabol, Iran. J North Khorasan Univ Med Sci 3(3), 7–14 (2011)
Tohidnia MR , Dezfolimanesh J, Almasi A: Bacterial contamination of radiography equipment in radiology departments of Kermanshah University of Medical Sciences (2010) J Kermanshah Univ Med Sci 16(3), 273–276 (2013)
Jalalvandi F , Teimouri B, Sohrabi N, Fakhri M, Shahsavari S, Jafari S: Microbial contamination of operating rooms equipments in selected hospitals in Kermanshah. Iran J Infect Dis Trop Med 17(59), 49–52 (2013)
Bell NP , Anand A, Wanger A, Prager TC: Microbial contamination of ultrasound biomicroscopy probes: evaluation of cross-infection risk. J Cataract Refract Surg 38(1), 174–175 (2012)
Afshar Yavari Sh , Diba K: The assessment of bacterial and fungal flora of operating rooms in Urmia Medical University hospitals. Urmia Med J 15(1), 33–38 (2004)
Ghenaat J , Sadeghian A, Ghazvini K: Surveillance of bacterial contamination in Ghaem Hospital during 10 Years (1370 to 1380). Iran J Otorhinolaryngol 16(3), 28–35 (2004)
Neil JA , Nye PF, Toven LA: Environmental surveillance in the operating room. AORN J 82(1), 43–50 (2005)
Alemu A , Misganaw D, Wondimeneh Y: Bacterial profile and their antimicrobial susceptibility patterns of computer keyboards and mice at Gondar University Hospital, Northwest Ethiopia. Biomed Biotechnol 3(1), 1–7 (2015)
Ensayef S , Al-Shalchi S, Sabbar M: Microbial contamination in the operating theatre: a study in a hospital in Baghdad. East Mediterr Health J 15(1), 219–223 (2009)
Halil Kilic I, Ozaslan M, Karagoz ID, Zer Y, Savas E, Davutoglu V: The role of stethoscopes in the transmission of hospital infections. Afr J Biotechnol 10(30), 5769–5772 (2011)