The paper presents an experimental research on anchoring devices developed for the pre-tensioning of fiber reinforced polymer tendons in the stress range between 40 and 70% of tensile strength. The technique of testing, the criteria of assessing the load capacity and the influence of preloading applied on the anchor wedges on the initial tendons slippage are described. The optimal technical configurations of the anchoring device have been obtained, including parameters regarding the necessary prior anchorage of the tendon ends based on the strength properties of the tendon bar and the requirements to avoid slippage during the tensile tests.

Abstract

The paper presents an experimental research on anchoring devices developed for the pre-tensioning of fiber reinforced polymer tendons in the stress range between 40 and 70% of tensile strength. The technique of testing, the criteria of assessing the load capacity and the influence of preloading applied on the anchor wedges on the initial tendons slippage are described. The optimal technical configurations of the anchoring device have been obtained, including parameters regarding the necessary prior anchorage of the tendon ends based on the strength properties of the tendon bar and the requirements to avoid slippage during the tensile tests.

1 Introduction

A variety of existing technical solutions for the pre-tensioning of composite Fiber Reinforced Polymer (FRP) tendons [1]-[15] shows that the problem of increasing the reliability of gripping and anchoring devices is of growing importance nowadays.

The most effective way to fix the tendon bar in the test sample is to place it send in the steel sleeve [2], tube [16] or tip [3] and polymerize it with an adhesive or glass-filled epoxy resin. This process provides appropriate conditions for minimal initial deformations in the area of the reinforcing tendon fixation, and results in maximum contact area and adhesion ratio. It is proposed in [17] to pour the gripping mechanism in a liquid form through a hole into the mould that contains the previously installed reinforcing rebar, and then press it with clamping elements. Paper [18] presents the results of experiments where fiberglass rods glued into the gripping parts were subjected to uniaxial tension. The author noted that 50% of the samples under tension have been damaged in the gripping part due to the breakdown of the adhesive layer between the sample and the steel sleeve, and the remaining 50% failed in the working part and were considered appraisable for defining the tensile strength. Paper [19] gives the results of tensile strength tests of several types of FRP rebars, carried out according to the Russian national standard [16]. In this test the following specimen failure pattern were noted: for small diameters (up to 5 mm), the rabar failed at its connection with the anchor device. It was concluded that the proper use of an adhesive substance would require further studies especially on the strength and adhesive properties in the solid state, as well as on the precise centering of the FRP rebars in the sleeves before the polymerization process [20].

Modern systems of steel reinforcement prestressing use collet clamps [21], which have to be constructively adapted for tensioning FRP rebars. This is primarily due to the different physico-mechanical properties (mainly of the working surface hardness) of the steel collet and FRP, low crack resistance of the polymer composite matrix material, relatively low shear strength of FRP due to the absence of reinforcement in the transverse direction.

The above-mentioned factors add up to the formation of surface microcracks in the contact zone and the destruction of the polymer composite matrix material and longitudinal fibers, including the point where reinforcement bar exits from the collet [22], [23], [24]. It is possible to solve this problem by either preventing the direct contact between the steel collet and the rod by using an intermediate sleeve [10], [25], or producing the collet using materials with physic-mechanical properties close to the FRP [1], [4]-[9], [13].

Article [26] shows that an increase in the load capacity of the tension system with an intermediate sleeve can be achieved by subjecting the inner surface of the sleeve to sandblasting, thus improving its frictional properties. The experiment confirmed that the friction coefficient and contact pressure are the main parameters affecting the strength of the cylinder-rod connection.

The second way to eliminate the stress concentration in the rod when using a collet clamp is to make the collet from a softer material. For example, a comparison of the experimental results on uniaxial tension using conventional collet grips of a tensile machine and plastic wedges adapted for testing FPR [27] showed a difference in ultimate tensile capacity. It determined the limiting characteristics of 30% associated with the destruction of a rebar in the area of steel collet.

Article [28] describes a condition for keeping the rod in the collet clamp under tension: the contact pressure should be lower at the loaded end of the rod and higher at the free end. This can be achieved by using collets of various stiffness along the length [5], [6], [7], [13], or using design features [12], that enable redistribution of contact pressures in the process of rebar tensioning. One of the design features is the angle of inclination of the cone collet and the body angle in the sleeve. It should be pointed out that recommendations of Russian [4], [29] and foreign authors [10], [12] differ.

Considering the information, mentioned above, the design of the tension device for FRP reinforcement is important, and requires not only the study of issues related to the theoretical justification of the design parameters of the device, but also the technology of manufacturing, subsequent experimental studies and recommendations for using this tension system for prestressing process of concrete structures.

2 Description of the test method for anchoring devices

Three series of tests of devices for tensioning of glass-composite reinforcement Glass Fiber Reinforced Polymer (GFRP) were carried out. Reinforcing rods had a diameter of 8 mm, a length of 520 mm, and three different surface treatments:

  • ‒ set 1, - the surface treatment is formed by winding the continuous fiber on the power rod;

  • ‒ set 2, - the surface treatment is formed by pressing out threads of homogeneous material in the FRP rod;

  • ‒ set 3, - an surface treatment is formed by application of sand coating.

The appearance of the investigated samples of the GFRP rebars is presented in Fig. 1. The geometric and mechanical characteristics that were obtained from previously performed tests to comply with the requirements of GOST 31938 - 2012 [16] are shown in Table I for GFRP rebars produced by different manufacturers.

Fig. 1
Fig. 1

FRP rods appearance

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

Table I

Geometric and mechanical characteristics of the tested GFRP rebars

Name of the indicatorSample Set Number
123
Nominal diameter dn, mm8.338.308.35
Tensile strength σu, МPа129111271194
Ultimate load at axial tension _, kN70.3260.9565.35
Modulus of elasticity Еf, GPa574750
Relative elongation εu up to failure. %2.32.42.4

Before testing, the ends of the reinforcement tendon were fixed by initial pressing of anchor wedges with F1 and F2 forces in mandrels №1 and №2 respectively (see Fig. 2), and then testing beacons (Fig. 3) were glued to the rod close to the ends of the cylinders for the determination of slippage.

Fig. 2
Fig. 2

Preliminary fixation of FRP rod in the mandrel: а) scheme; b) full-scale specimen

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

Fig. 3
Fig. 3

a) A testing configuration of devices used for tensioning the reinforcement; b) and full-scale view of the sample in gripping device

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

Next, the cylinder with a reinforcing rod is fastened in the gripping devices of the testing machine Instron 5982. The testing configuration is presented in Fig. 3. The tension force Fp was set from 0.4 to 0.7 of the ultimate load at axial tension Fult, the speed of the plate movement was set to 10 mm/min.

After reaching a given force and holding for 60 seconds, the load was removed. The gaps Δh1, Δh2 were visually assessed and measured with a ruler when it was necessary.

In some cases, it was noted that the slippage of the rebar in the mandrel corresponded to an abrupt change in the tension force, which made it possible to determine the initial moment of slippage and the corresponding force Fss according to the loading diagram (Fig. 4, curve 2).

Fig. 4
Fig. 4

Axial tension diagrams of rebar: 1 - without slippage; 2 - with slippage of the rod in the gripping device

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

For each test, parameters regarding pre-fixing of the reinforcement and the tension characteristics were registered.

3 Analysis of test results

Based on the method presented in the previous section, tests on different types of anchoring devices were carried out. Typical tension diagrams of reinforcement sample sets 1, 2 and 3 are presented in Fig. 5, respectively (the initial pressing force applied on anchor wedges was in the range of 41 kN and 42 kN).

Fig. 5
Fig. 5

Tendons tension diagrams: а) set 1; b) set 2; c) set 3

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

Diagrams show that the slippage of the ribbed reinforcing bars of set 1 is characterized by a sharp drop in the tension force (by 35-40%) and a lower value of the initial sliding moment force. It can be explained by the specific characteristics of manufacturing and the weaker frictional properties of the tendons surface compared to other samples sets.

The test results of samples of reinforcement bars of set 1, set 2 and set 3 are presented in Fig. 6. They include obtained values of forces at the moment of initial sliding depending on the forces of preliminary pressing of anchor wedges and their trend line. Force F corresponds to the minimum of forces F1 and F2 for each test.

Fig. 6
Fig. 6

Experimentally obtained values of force at the initial moment of sliding depending on the force of preliminary pressing of anchor wedges with a length of l = 70 mm ( - series 1, - series 2, -series 3)

for GFRP rods of set 1, the pressing force is 50 kN, which provides the force of the initial moment of slipping Fss= 33.3 kN, or 48% of the ultimate load F = 70.32 kN;

for GFRP rods of set 2, the pressing force is 40 kN, which provides the force of the initial moment of slipping Fss= 31.2 kN, or 51% of the ultimate load F= 60.95 kN;

for GFRP rods of set 3, the pressing force is 55 kN, which provides the force of the initial moment of slipping Fss= 46.6 kN, or 72% of the ultimate load F = 65.35 kN.

Citation: Pollack Periodica Pollack 15, 3; 10.1556/606.2020.15.3.13

Tests carried out on the device for tensioning the GFRP rods with anchor wedges with a length of 70 mm have shown that the maximum holding capacity is different when GFRP rods of a different profile are exposed to the short-term tensile load.

The composite rod is fixed according to the regulatory requirements of 0.45σ in accordance with SP 295.1325800.2017 ‘Concrete structures reinforced with polymer composite reinforcement design rules’ by pre-fixing the ends of the rod and by providing compression of the polymer anchor wedges by pressing them depending on the type of FRP rod with forces as follows:

4 Conclusions

Results of experimental tests carried out on the developed device for placing and fixing reinforcing composite rebars and tendons have confirmed appropriate working capacity and successful avoidance of slippage during the tests in the required range of tension forces.

It was noted that the material of anchor wedges, the strength and intensity of the preloading of fixing wedges, and the manufacturing technology of the reinforcing rebars have a significant effect on the performance of the gripping device.

It is concluded that for each diameter of the reinforcing rebar and type of profile to be tested, different parameter configurations are required to determine adequate fixing forces that enable the required tension of reinforcing tendons and tendons in prestressed concrete products.

For the developed gripping device recommended parameters of preliminary fixing of the reinforcing GFRP rods with a diameter of 8 mm and three different surface treatments were derived, ensuring their compliance with the regulatory requirements.

  • [1]

    RU patent № 2008100546/22, Anchoring device for ribbed reinforcing bars, applicant and patent holder Ltd, ‘Biysk fiberglass plant’, (in Russian) 2008.

    • Search Google Scholar
    • Export Citation
  • [2]

    RU patent № 2015127522/28, Sleeve for holding the rod of composite reinforcement, pulled out of concrete, applicant and patent holder FSEI of HE ‘Ivanovo State Polytechnic University’, (in Russian) 2016.

    • Search Google Scholar
    • Export Citation
  • [3]

    RU patent № 2017110306, Connection element with a tip, applicant and patent holder V. N. Soplyachenko, O. G. Rogozhin, (in Russian) 2018.

    • Search Google Scholar
    • Export Citation
  • [4]

    RU patent № 2016126915, Anchor device for fixing pre-stressed reinforcing bars, applicant and patent holder B.Sh. Umarov, ‘Kazan State University of Architecture and Engineering’, (in Russian) 2018.

    • Search Google Scholar
    • Export Citation
  • [5]

    RU patent № 2016103166, Anchor for composite reinforcement element, applicant and patent holder V. N. Nikolaev, (in Russian) 2017.

  • [6]

    RU patent № 2016137575, Anchor for composite reinforcement element, V. N. Nikolaev, (in Russian) 2017.

  • [7]

    RU patent № 2016136420, Anchor for holding the power element made of composite material, applicant and patent holder: Institute of Applied Mechanics of the Russian Academy of Sciences, (in Russian) 2017.

    • Search Google Scholar
    • Export Citation
  • [8]

    RU patent № 2015145714, Device for anchoring composite reinforcement: B. V. Nakashidze, P. B. Berezin, D. G. Nakashidze, (in Russian) 2017.

    • Search Google Scholar
    • Export Citation
  • [9]

    BU patent № 20090077, Device for fastening the ends of fiberglass reinforcement, applicant and patent holder: Educational institution ‘Polotsk State University’, (in Russian) 2009.

    • Search Google Scholar
    • Export Citation
  • [10]

    СN patent № 104727487A, Composite CFRP (Carbon Fibre Reinforced Polymer) tendon anchoring system, Han Qinghua, Wang Lichen, Xu Jie, Lu Yan, Xu Ying, 2015.

    • Search Google Scholar
    • Export Citation
  • [11]

    US patent № 4958961, Anchoring arrangement for a rodshaped tension member formed of fiber reinforced composite material, Thomas Herbst, Dieter Jungwirt, 1990.

    • Search Google Scholar
    • Export Citation
  • [12]

    US patent № 5437526A, Arrangement for anchoring a rod-shaped tension member of composite fiber material, Thomas Herbst, Berthold Bolmer, Hartmut von Grolman, Anton Liigering, Lorenz Schnitzler, 1995.

    • Search Google Scholar
    • Export Citation
  • [13]

    US patent № 5713169A, Anchorage device for high performance fiber composite cables, Urs Meier, Heinz Meier, Patrick Ki, 1998.

  • [14]

    Orban Z. Temporary strengthening of steel bridge element with FRP sheet, Pollack Periodica, Vol. 9, No. 2, 2014, pp. 3544.

  • [15]

    Krasniqi C., Kabashi N., Krasniqi E., Kaqi V. Comparison of the behavior of GFRP reinforced concrete beams with conventional steel bars, Pollack Periodica, Vol. 13, No. 3, 2018, pp. 141150.

    • Search Google Scholar
    • Export Citation
  • [16]

    GOST 31938-2012, Fiber-reinforced polymer bar for concrete reinforcement, General specifications, adopted 01-01-2014, М. Standardinform, 2001.

    • Search Google Scholar
    • Export Citation
  • [17]

    BU Patent № 20130021, Device for fastening the ends of fiberglass reinforcement, applicant and patent holder Educational institution ‘Polotsk State University’, 2013.

    • Search Google Scholar
    • Export Citation
  • [18]

    Lobanov D. S. Experimental studies of the deformation and strength properties of polymer composite materials and filler panels, (in Russian). Thesis for Candidate Degree in Sciences, Perm National Research Politechnical University, 2015.

    • Search Google Scholar
    • Export Citation
  • [19]

    izdatullin A. R., Khozin V. G., Kuklin A. N., Khusnutdinov A. M. Features of testing and the nature of the destruction of polymer composite reinforcement, (in Russian). Engineering Journal, No. 3, 2014, pp. 4047.

    • Search Google Scholar
    • Export Citation
  • [20]

    Stepanova V. F., Stepanov A. Yu., Zhirkov E. P. Composite polymer reinforcement, Moscow, ASV, 2013.

  • [21]

    Anchor wedges, (in German) http://www.paul.eu/ru/produkte/spannbeton-technik/spannverankerungen.html (last visited 25 November 2019).

  • [22]

    Al-Mayah A., Soudki K., Plumtree A. Mechanical behavior of CFRP rod anchors under tensile loading, Journal of Composites for Construction, Vol. 5, No. 2, 2001, pp. 4853.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [23]

    Bennitz A., Schmidt J. W. TäljstenB. Failure modes of prestressed CFRP rods in a wedge anchorage set-up, Proceedings of the 4th International Conference on Advanced Composites in Construction, Vol. 4, Edinburgh, United Kingdom, 1-3 September 2009, pp. 104114.

    • Search Google Scholar
    • Export Citation
  • [24]

    US Patent № 6082063, Prestressing anchorage system for fiber reinforced plastic tendons, Shrive N. G., 2000.

  • [25]

    ACI 440.4R, Prestressing concrete structures with FRP tendons, 2004.

  • [26]

    Al-Mayah A., Soudki K., Plumtree A. Effect of sandblasting on interfacial contact behavior of carbon-fiber-reinforced polymer-metal couples, Journal of Composites for Construction, Vol. 9, No. 4, 2005, pp. 2943.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [27]

    Gar S. P. Structural performance of a full-depth precast bridge deck system prestressed and reinforced with AFRP bars, PhD Theis, Texas A&M University, 2012.

    • Search Google Scholar
    • Export Citation
  • [28]

    Al-Mayah A., Soudki K., Plumtree A. Novel anchor system for CFRP rod: Finite-element and mathematical models, Journal of Composites for Construction, Vol. 11, No. 5, 2007, pp. 355359.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [29]

    RU Patent № 2011118956/03, Anchor device for composite reinforcement, applicant and patent holder LLC GALEN, (in Russian) 2011.

  • [1]

    RU patent № 2008100546/22, Anchoring device for ribbed reinforcing bars, applicant and patent holder Ltd, ‘Biysk fiberglass plant’, (in Russian) 2008.

    • Search Google Scholar
    • Export Citation
  • [2]

    RU patent № 2015127522/28, Sleeve for holding the rod of composite reinforcement, pulled out of concrete, applicant and patent holder FSEI of HE ‘Ivanovo State Polytechnic University’, (in Russian) 2016.

    • Search Google Scholar
    • Export Citation
  • [3]

    RU patent № 2017110306, Connection element with a tip, applicant and patent holder V. N. Soplyachenko, O. G. Rogozhin, (in Russian) 2018.

    • Search Google Scholar
    • Export Citation
  • [4]

    RU patent № 2016126915, Anchor device for fixing pre-stressed reinforcing bars, applicant and patent holder B.Sh. Umarov, ‘Kazan State University of Architecture and Engineering’, (in Russian) 2018.

    • Search Google Scholar
    • Export Citation
  • [5]

    RU patent № 2016103166, Anchor for composite reinforcement element, applicant and patent holder V. N. Nikolaev, (in Russian) 2017.

  • [6]

    RU patent № 2016137575, Anchor for composite reinforcement element, V. N. Nikolaev, (in Russian) 2017.

  • [7]

    RU patent № 2016136420, Anchor for holding the power element made of composite material, applicant and patent holder: Institute of Applied Mechanics of the Russian Academy of Sciences, (in Russian) 2017.

    • Search Google Scholar
    • Export Citation
  • [8]

    RU patent № 2015145714, Device for anchoring composite reinforcement: B. V. Nakashidze, P. B. Berezin, D. G. Nakashidze, (in Russian) 2017.

    • Search Google Scholar
    • Export Citation
  • [9]

    BU patent № 20090077, Device for fastening the ends of fiberglass reinforcement, applicant and patent holder: Educational institution ‘Polotsk State University’, (in Russian) 2009.

    • Search Google Scholar
    • Export Citation
  • [10]

    СN patent № 104727487A, Composite CFRP (Carbon Fibre Reinforced Polymer) tendon anchoring system, Han Qinghua, Wang Lichen, Xu Jie, Lu Yan, Xu Ying, 2015.

    • Search Google Scholar
    • Export Citation
  • [11]

    US patent № 4958961, Anchoring arrangement for a rodshaped tension member formed of fiber reinforced composite material, Thomas Herbst, Dieter Jungwirt, 1990.

    • Search Google Scholar
    • Export Citation
  • [12]

    US patent № 5437526A, Arrangement for anchoring a rod-shaped tension member of composite fiber material, Thomas Herbst, Berthold Bolmer, Hartmut von Grolman, Anton Liigering, Lorenz Schnitzler, 1995.

    • Search Google Scholar
    • Export Citation
  • [13]

    US patent № 5713169A, Anchorage device for high performance fiber composite cables, Urs Meier, Heinz Meier, Patrick Ki, 1998.

  • [14]

    Orban Z. Temporary strengthening of steel bridge element with FRP sheet, Pollack Periodica, Vol. 9, No. 2, 2014, pp. 3544.

  • [15]

    Krasniqi C., Kabashi N., Krasniqi E., Kaqi V. Comparison of the behavior of GFRP reinforced concrete beams with conventional steel bars, Pollack Periodica, Vol. 13, No. 3, 2018, pp. 141150.

    • Search Google Scholar
    • Export Citation
  • [16]

    GOST 31938-2012, Fiber-reinforced polymer bar for concrete reinforcement, General specifications, adopted 01-01-2014, М. Standardinform, 2001.

    • Search Google Scholar
    • Export Citation
  • [17]

    BU Patent № 20130021, Device for fastening the ends of fiberglass reinforcement, applicant and patent holder Educational institution ‘Polotsk State University’, 2013.

    • Search Google Scholar
    • Export Citation
  • [18]

    Lobanov D. S. Experimental studies of the deformation and strength properties of polymer composite materials and filler panels, (in Russian). Thesis for Candidate Degree in Sciences, Perm National Research Politechnical University, 2015.

    • Search Google Scholar
    • Export Citation
  • [19]

    izdatullin A. R., Khozin V. G., Kuklin A. N., Khusnutdinov A. M. Features of testing and the nature of the destruction of polymer composite reinforcement, (in Russian). Engineering Journal, No. 3, 2014, pp. 4047.

    • Search Google Scholar
    • Export Citation
  • [20]

    Stepanova V. F., Stepanov A. Yu., Zhirkov E. P. Composite polymer reinforcement, Moscow, ASV, 2013.

  • [21]

    Anchor wedges, (in German) http://www.paul.eu/ru/produkte/spannbeton-technik/spannverankerungen.html (last visited 25 November 2019).

  • [22]

    Al-Mayah A., Soudki K., Plumtree A. Mechanical behavior of CFRP rod anchors under tensile loading, Journal of Composites for Construction, Vol. 5, No. 2, 2001, pp. 4853.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [23]

    Bennitz A., Schmidt J. W. TäljstenB. Failure modes of prestressed CFRP rods in a wedge anchorage set-up, Proceedings of the 4th International Conference on Advanced Composites in Construction, Vol. 4, Edinburgh, United Kingdom, 1-3 September 2009, pp. 104114.

    • Search Google Scholar
    • Export Citation
  • [24]

    US Patent № 6082063, Prestressing anchorage system for fiber reinforced plastic tendons, Shrive N. G., 2000.

  • [25]

    ACI 440.4R, Prestressing concrete structures with FRP tendons, 2004.

  • [26]

    Al-Mayah A., Soudki K., Plumtree A. Effect of sandblasting on interfacial contact behavior of carbon-fiber-reinforced polymer-metal couples, Journal of Composites for Construction, Vol. 9, No. 4, 2005, pp. 2943.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [27]

    Gar S. P. Structural performance of a full-depth precast bridge deck system prestressed and reinforced with AFRP bars, PhD Theis, Texas A&M University, 2012.

    • Search Google Scholar
    • Export Citation
  • [28]

    Al-Mayah A., Soudki K., Plumtree A. Novel anchor system for CFRP rod: Finite-element and mathematical models, Journal of Composites for Construction, Vol. 11, No. 5, 2007, pp. 355359.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • [29]

    RU Patent № 2011118956/03, Anchor device for composite reinforcement, applicant and patent holder LLC GALEN, (in Russian) 2011.

Submit Your Manuscript
 
The author instructions template is available in MS Word.
Please, download the file from HERE.

 

Senior editors

Editor(s)-in-Chief: Iványi, Amália

Editor(s)-in-Chief: Iványi, Péter

 

Scientific Secretary

Miklós M. Iványi

Editorial Board

  • Bálint Bachmann (Institute of Architecture, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Jeno Balogh (Department of Civil Engineering Technology, Metropolitan State University of Denver, Denver, Colorado, USA)
  • Radu Bancila (Department of Geotechnical Engineering and Terrestrial Communications Ways, Faculty of Civil Engineering and Architecture, “Politehnica” University Timisoara, Romania)
  • Charalambos C. Baniotopolous (Department of Civil Engineering, Chair of Sustainable Energy Systems, Director of Resilience Centre, School of Engineering, University of Birmingham, U.K.)
  • Oszkar Biro (Graz University of Technology, Institute of Fundamentals and Theory in Electrical Engineering, Austria)
  • Ágnes Borsos (Institute of Architecture, Department of Interior, Applied and Creative Design, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Matteo Bruggi (Dipartimento di Ingegneria Civile e Ambientale, Politecnico di Milano, Italy)
  • Ján Bujňák (Department of Structures and Bridges, Faculty of Civil Engineering, University of Žilina, Slovakia)
  • Anikó Borbála Csébfalvi (Department of Civil Engineering, Institute of Smart Technology and Engineering, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Mirjana S. Devetaković (Faculty of Architecture, University of Belgrade, Serbia)
  • Szabolcs Fischer (Department of Transport Infrastructure and Water Resources Engineering, Faculty of Architerture, Civil Engineering and Transport Sciences Széchenyi István University, Győr, Hungary)
  • Radomir Folic (Department of Civil Engineering, Faculty of Technical Sciences, University of Novi Sad Serbia)
  • Jana Frankovská (Department of Geotechnics, Faculty of Civil Engineering, Slovak University of Technology in Bratislava, Slovakia)
  • János Gyergyák (Department of Architecture and Urban Planning, Institute of Architecture, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Kay Hameyer (Chair in Electromagnetic Energy Conversion, Institute of Electrical Machines, Faculty of Electrical Engineering and Information Technology, RWTH Aachen University, Germany)
  • Elena Helerea (Dept. of Electrical Engineering and Applied Physics, Faculty of Electrical Engineering and Computer Science, Transilvania University of Brasov, Romania)
  • Ákos Hutter (Department of Architecture and Urban Planning, Institute of Architecture, Faculty of Engineering and Information Technolgy, University of Pécs, Hungary)
  • Károly Jármai (Institute of Energy and Chemical Machinery, Faculty of Mechanical Engineering and Informatics, University of Miskolc, Hungary)
  • Teuta Jashari-Kajtazi (Department of Architecture, Faculty of Civil Engineering and Architecture, University of Prishtina, Kosovo)
  • Róbert Kersner (Department of Technical Informatics, Institute of Information and Electrical Technology, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Rita Kiss  (Biomechanical Cooperation Center, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary)
  • István Kistelegdi  (Department of Building Structures and Energy Design, Institute of Architecture, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Stanislav Kmeť (President of University Science Park TECHNICOM, Technical University of Kosice, Slovakia)
  • Imre Kocsis  (Department of Basic Engineering Research, Faculty of Engineering, University of Debrecen, Hungary)
  • László T. Kóczy (Department of Information Sciences, Faculty of Mechanical Engineering, Informatics and Electrical Engineering, University of Győr, Hungary)
  • Dražan Kozak (Faculty of Mechanical Engineering, Josip Juraj Strossmayer University of Osijek, Croatia)
  • György L. Kovács (Department of Technical Informatics, Institute of Information and Electrical Technology, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Balázs Géza Kövesdi (Department of Structural Engineering, Faculty of Civil Engineering, Budapest University of Engineering and Economics, Budapest, Hungary)
  • Tomáš Krejčí (Department of Mechanics, Faculty of Civil Engineering, Czech Technical University in Prague, Czech Republic)
  • Jaroslav Kruis (Department of Mechanics, Faculty of Civil Engineering, Czech Technical University in Prague, Czech Republic)
  • Miklós Kuczmann (Department of Automations, Faculty of Mechanical Engineering, Informatics and Electrical Engineering, Széchenyi István University, Győr, Hungary)
  • Tibor Kukai (Department of Engineering Studies, Institute of Smart Technology and Engineering, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Maria Jesus Lamela-Rey (Departamento de Construcción e Ingeniería de Fabricación, University of Oviedo, Spain)
  • János Lógó  (Department of Structural Mechanics, Faculty of Civil Engineering, Budapest University of Technology and Economics, Hungary)
  • Carmen Mihaela Lungoci (Faculty of Electrical Engineering and Computer Science, Universitatea Transilvania Brasov, Romania)
  • Frédéric Magoulés (Department of Mathematics and Informatics for Complex Systems, Centrale Supélec, Université Paris Saclay, France)
  • Gabriella Medvegy (Department of Interior, Applied and Creative Design, Institute of Architecture, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Tamás Molnár (Department of Visual Studies, Institute of Architecture, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Ferenc Orbán (Department of Mechanical Engineering, Institute of Smart Technology and Engineering, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Zoltán Orbán (Department of Civil Engineering, Institute of Smart Technology and Engineering, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Dmitrii Rachinskii (Department of Mathematical Sciences, The University of Texas at Dallas, Texas, USA)
  • Chro Radha (Chro Ali Hamaradha) (Sulaimani Polytechnic University, Technical College of Engineering, Department of City Planning, Kurdistan Region, Iraq)
  • Maurizio Repetto (Department of Energy “Galileo Ferraris”, Politecnico di Torino, Italy)
  • Zoltán Sári (Department of Technical Informatics, Institute of Information and Electrical Technology, Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Grzegorz Sierpiński (Department of Transport Systems and Traffic Engineering, Faculty of Transport, Silesian University of Technology, Katowice, Poland)
  • Zoltán Siménfalvi (Institute of Energy and Chemical Machinery, Faculty of Mechanical Engineering and Informatics, University of Miskolc, Hungary)
  • Andrej Šoltész (Department of Hydrology, Faculty of Civil Engineering, Slovak University of Technology in Bratislava, Slovakia)
  • Zsolt Szabó (Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Hungary)
  • Mykola Sysyn (Chair of Planning and Design of Railway Infrastructure, Institute of Railway Systems and Public Transport, Technical University of Dresden, Germany)
  • András Timár (Faculty of Engineering and Information Technology, University of Pécs, Hungary)
  • Barry H. V. Topping (Heriot-Watt University, UK, Faculty of Engineering and Information Technology, University of Pécs, Hungary)

POLLACK PERIODICA
Pollack Mihály Faculty of Engineering
Institute: University of Pécs
Address: Boszorkány utca 2. H–7624 Pécs, Hungary
Phone/Fax: (36 72) 503 650

E-mail: peter.ivanyi@mik.pte.hu 

or amalia.ivanyi@mik.pte.hu

Indexing and Abstracting Services:

  • SCOPUS

 

2020  
Scimago
H-index
11
Scimago
Journal Rank
0,257
Scimago
Quartile Score
Civil and Structural Engineering Q3
Computer Science Applications Q3
Materials Science (miscellaneous) Q3
Modeling and Simulation Q3
Software Q3
Scopus
Cite Score
340/243=1,4
Scopus
Cite Score Rank
Civil and Structural Engineering 219/318 (Q3)
Computer Science Applications 487/693 (Q3)
General Materials Science 316/455 (Q3)
Modeling and Simulation 217/290 (Q4)
Software 307/389 (Q4)
Scopus
SNIP
1,09
Scopus
Cites
321
Scopus
Documents
67
Days from submission to acceptance 136
Days from acceptance to publication 239
Acceptance
Rate
48%

 

2019  
Scimago
H-index
10
Scimago
Journal Rank
0,262
Scimago
Quartile Score
Civil and Structural Engineering Q3
Computer Science Applications Q3
Materials Science (miscellaneous) Q3
Modeling and Simulation Q3
Software Q3
Scopus
Cite Score
269/220=1,2
Scopus
Cite Score Rank
Civil and Structural Engineering 206/310 (Q3)
Computer Science Applications 445/636 (Q3)
General Materials Science 295/460 (Q3)
Modeling and Simulation 212/274 (Q4)
Software 304/373 (Q4)
Scopus
SNIP
0,933
Scopus
Cites
290
Scopus
Documents
68
Acceptance
Rate
67%

 

Pollack Periodica
Publication Model Hybrid
Submission Fee none
Article Processing Charge 900 EUR/article
Printed Color Illustrations 40 EUR (or 10 000 HUF) + VAT / piece
Regional discounts on country of the funding agency World Bank Lower-middle-income economies: 50%
World Bank Low-income economies: 100%
Further Discounts Editorial Board / Advisory Board members: 50%
Corresponding authors, affiliated to an EISZ member institution subscribing to the journal package of Akadémiai Kiadó: 100%
Subscription fee 2021 Online subsscription: 321  EUR / 402 USD
Print + online subscription: 384 EUR / 480 USD
Subscription fee 2022 Online subsscription: 327 EUR / 411 USD 321
Print + online subscription: 393 EUR / 492 USD
Subscription Information Online subscribers are entitled access to all back issues published by Akadémiai Kiadó for each title for the duration of the subscription, as well as Online First content for the subscribed content.
Purchase per Title Individual articles are sold on the displayed price.

 

Pollack Periodica
Language English
Size A4
Year of
Foundation
2006
Publication
Programme
2021 Volume 16
Volumes
per Year
1
Issues
per Year
3
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 1788-1994 (Print)
ISSN 1788-3911 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Apr 2021 0 20 4
May 2021 0 19 10
Jun 2021 0 18 6
Jul 2021 0 25 11
Aug 2021 0 18 14
Sep 2021 0 18 16
Oct 2021 0 0 0