Authors:
Łukasz Komsta Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland

Search for other papers by Łukasz Komsta in
Current site
Google Scholar
PubMed
Close
,
Robert Skibiński Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland

Search for other papers by Robert Skibiński in
Current site
Google Scholar
PubMed
Close
,
Sebastian Gadowski Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland

Search for other papers by Sebastian Gadowski in
Current site
Google Scholar
PubMed
Close
,
Joanna Wróbel Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland

Search for other papers by Joanna Wróbel in
Current site
Google Scholar
PubMed
Close
, and
Karolina Skrzypiec Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland

Search for other papers by Karolina Skrzypiec in
Current site
Google Scholar
PubMed
Close
Restricted access

The eluotropic strength on RP2 and RP8 plates was investigated for 7 chromatographic grade solvents miscible with water as a diluent (acetone, acetonitrile, dioxane, ethanol, isopropanol, methanol, and tetrahydrofuran) as well as for water itself. Thirty-five model compounds were used as a test set in the investigation. The use of a modern chemometric mixture design concept allowed separate estimation of each solvent effect from the other results with a relatively small error (about 0.05 of RM value for both adsorbents). Principal component analysis was used as an additional tool and revealed that only one parameter (mean eluotropic strength) is satisfactory to explain the overall variability in the retention datasets. The bootstrapping approach was also used to check the distribution and uncertainty of the obtained values. It can be concluded that all solvents have quite similar elution strength for both adsorbents. The obtained values can be used as a reference during the optimization of thin-layer chromatography (TLC) systems.

  • [1]

    L.R. Snyder , J. Chromatogr. 92 (1974) 223230.

  • [2]

    L.R. Snyder , J. Chromatogr. Sci. 16 (1978) 223234.

  • [3]

    L.R. Snyder , Anal. Chem. 46 (1974) 13841393.

  • [4]

    R.D. Snee , D.W. Marquardt, Technometrics 18 (1976) 1929.

  • [5]

    Ł. Komsta , B. Stepkowska, R. Skibiński, J. Chromatogr. A 1483 (2017) 138141.

  • [6]

    Ł. Komsta , U. Dunin, R. Skibiński, J. Planar Chromatogr. 30 (2017) 401404.

  • [7]

    A. de Juan , G. Fonrodona, E. Casassas, Trends Anal. Chem. 16 (1997) 5262.

  • [8]

    S.K. Poole , C.F. Poole, Chromatographia 53 (2001) 162166.

  • [9]

    Ł. Komsta , R. Skibiński, A. Gumieniczek, A. Wojnar, Acta Chromatogr. 22 (2010) 2736.

  • Collapse
  • Expand

To see the editorial board, please visit the website of Springer Nature.

Manuscript Submission: HERE

For subscription options, please visit the website of Springer Nature.

Journal of Planar Chromatography - Modern TLC
Language English
Size A4
Year of
Foundation
1988
Volumes
per Year
1
Issues
per Year
6
Founder Akadémiai Kiadó
Founder's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
Publisher Akadémiai Kiadó
Springer Nature Switzerland AG
Publisher's
Address
H-1117 Budapest, Hungary 1516 Budapest, PO Box 245.
CH-6330 Cham, Switzerland Gewerbestrasse 11.
Responsible
Publisher
Chief Executive Officer, Akadémiai Kiadó
ISSN 0933-4173 (Print)
ISSN 1789-0993 (Online)

Monthly Content Usage

Abstract Views Full Text Views PDF Downloads
Apr 2024 11 0 0
May 2024 2 0 0
Jun 2024 10 0 0
Jul 2024 21 0 0
Aug 2024 24 0 0
Sep 2024 17 0 0
Oct 2024 2 0 0